Dyness error codes explained
What 6 Dyness battery fault and error codes mean, in plain English, with safe checks you can do and when to call a licensed electrician.
Safety first: never open the switchboard, remove covers, or pull apart or disconnect the inverter, batteries, isolators or wiring. Only use the switches and buttons described here. Anything else must be done by a licensed electrician. Call 1300 209 503 or book a service request.
| Code | Message & meaning |
|---|---|
| Charge: Over-currentFault |
Charging over-current (red ALM light, buzzer)Charging over-current (red ALM light, buzzer) What you can do
DL5.0C low-voltage battery · Guide only. All work must be done by a licensed electrician. |
| Charge: High tempWarning |
Charging high temperature (red ALM light)Charging high temperature (red ALM light) What you can do
DL5.0C low-voltage battery · Guide only. All work must be done by a licensed electrician. |
| Discharge: Over-currentFault |
Discharging over-current (red ALM light, buzzer)Discharging over-current (red ALM light, buzzer) What you can do
DL5.0C low-voltage battery · Guide only. All work must be done by a licensed electrician. |
| Discharge: High tempWarning |
Discharging high temperature (red ALM light)Discharging high temperature (red ALM light) What you can do
DL5.0C low-voltage battery · Guide only. All work must be done by a licensed electrician. |
| Discharge: Total voltage undervoltageFault |
Total voltage undervoltage (red ALM light, buzzer)Total voltage undervoltage (red ALM light, buzzer) What you can do
DL5.0C low-voltage battery · Guide only. All work must be done by a licensed electrician. |
| Discharge: Cell voltage undervoltageFault |
Cell voltage undervoltage (red ALM light, buzzer)Cell voltage undervoltage (red ALM light, buzzer) What you can do
DL5.0C low-voltage battery · Guide only. All work must be done by a licensed electrician. |
No codes match. Try fewer characters, or ask us.
Common Dyness questions
What does Dyness Charge: Over-current "Charging over-current (red ALM light, buzzer)" mean?
Charging over-current (red ALM light, buzzer) Turn off any very large loads that were running when the alarm appeared This is a guide only; any electrical work must be done by a licensed electrician.
What does Dyness Discharge: Over-current "Discharging over-current (red ALM light, buzzer)" mean?
Discharging over-current (red ALM light, buzzer) Turn off any very large loads that were running when the alarm appeared This is a guide only; any electrical work must be done by a licensed electrician.
What does Dyness Discharge: Total voltage undervoltage "Total voltage undervoltage (red ALM light, buzzer)" mean?
Total voltage undervoltage (red ALM light, buzzer) Note the code and the battery state of charge shown in the app This is a guide only; any electrical work must be done by a licensed electrician.
What does Dyness Discharge: Cell voltage undervoltage "Cell voltage undervoltage (red ALM light, buzzer)" mean?
Cell voltage undervoltage (red ALM light, buzzer) Note the code and the battery state of charge shown in the app This is a guide only; any electrical work must be done by a licensed electrician.
What does Dyness Charge: High temp "Charging high temperature (red ALM light)" mean?
Charging high temperature (red ALM light) Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents This is a guide only; any electrical work must be done by a licensed electrician.
Need help with this fault?
Get a licensed electrician to call you back.
Total Solar can help: our licensed electricians install and service systems. Based in Ellenbrook, WA, with Victoria and Queensland also available.
Or call 1300 209 503
Sources
Meanings are summarised from these manufacturer documents. Check your own model's manual, as codes vary between models and firmware versions.
Dyness is a trademark of its owner. Total Solar is not affiliated with the manufacturer unless stated. All fault code guides