Enphase error codes explained
What 43 Enphase inverter & battery fault and error codes mean, in plain English, with safe checks you can do and when to call a licensed electrician.
Safety first: never open the switchboard, remove covers, or pull apart or disconnect the inverter, batteries, isolators or wiring. Only use the switches and buttons described here. Anything else must be done by a licensed electrician. Call 1300 209 503 or book a service request.
| Code | Message & meaning |
|---|---|
| LED flashing greenInfo |
Normal operationNormal operation. The grid is normal and the microinverter is talking to the IQ Gateway. What you can do
IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H microinverters · Guide only. All work must be done by a licensed electrician. |
| LED flashing orangeWarning |
No communication with IQ GatewayThe grid is normal, but the microinverter is not communicating with the IQ Gateway, so monitoring may be missing. What you can do
IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H microinverters · Guide only. All work must be done by a licensed electrician. |
| LED flashing redWarning |
Grid not present or out of specificationThe AC grid is either not present or not within the specification, so the microinverter is not producing. What you can do
IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H microinverters · Guide only. All work must be done by a licensed electrician. |
| LED solid redCritical |
DC Resistance Low - Power Off conditionThe microinverter has detected low insulation resistance between the panel wiring and earth (possible defective module insulation, wiring/connectors or moisture) and has stopped producing. It stays off until the sensor is reset. What you can do
IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H microinverters · Guide only. All work must be done by a licensed electrician. |
| Short red blinks at start-upFault |
Start-up failureShort red blinks after DC power is first applied indicate a failure during microinverter start-up. What you can do
IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H microinverters · Guide only. All work must be done by a licensed electrician. |
| AC Frequency Changing Too FastWarning |
AC Frequency Changing Too FastAC frequency is the frequency at which voltage varies on the electricity network. The microinverter reports that this value is changing more rapidly than allowed. Frequency Changing Too Fast events are usually transient and self-correcting by the electricity network. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| AC Frequency Out Of RangeWarning |
AC Frequency Out Of RangeThe microinverter reports that the frequency coming from the electricity network is either too low or too high as specified by applicable regional standards. AC frequency is the frequency at which voltage varies on the electricity network. Frequency Out of Range events are usually transient and self- correcting by the electricity network. When the microinverter detects an out of frequency condition, it must remain offline until the electricity network has been within acceptable limits continuously for a short period of time (seconds to minutes, varies by region). If, during that time, the utility again exceeds or falls short of acceptable limits, the timer must restart and the microinverter may not begin producing power for an additional short period following the last out- of-bounds condition. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| ACMonitorErrorWarning |
ACMonitorErrorThe microinverter is temporarily unable perform power conversion. If the condition repeats or persists: Contact your installer to arrange for the installation of a replacement microinverter. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| AC Voltage Average HighWarning |
AC Voltage Average HighThe microinverter reports that the average AC voltage coming from the utility over the past 10 minutes was too high for the configured grid profile. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| AC Voltage Out Of RangeWarning |
AC Voltage Out Of RangeThe microinverter reports that the AC voltage coming from the utility is either too low or too high as specified by applicable regional standards. When a microinverter detects the voltage out of range condition, it does not produce power (per regulation) until the utility voltage returns within acceptable limits for several minutes (time varies by region). If during that time the utility voltage again goes beyond acceptable limits, the timer restarts. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Applying grid profile xx from regulatory specification yyInfo |
Applying grid profile xx from regulatory specification yyThe Envoy has started a change to the grid profile for the microinverters. This process may take a few minutes. No action is required. xx = grid profile name yy = Regional specification name. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Bad Flash ImageFault |
Bad Flash ImageThe microinverter is not producing power due to a software problem. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Commanded ResetInfo |
Commanded ResetThe microinverter was reset, either following a successful software download or by user command. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Control RequestInfo |
Control RequestThe Envoy has received a control request made via the Envoy interface (Administration > Device Conditions and Controls page) or via Enlighten. This uncommon condition will occur only during isolated troubleshooting procedures by Enphase personnel. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Critical TemperatureWarning |
Critical TemperatureThis rare condition occurs if the microinverter reports an internal temperature that exceeds its rated range. It reacts by producing less power to reduce internal temperature. This reflects internal temperature coming from a sensor inside the microinverter, not the ambient temperature. Once the internal temperature of the microinverter is once again within normal limits, it will resume full power production and this event message will clear. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| DC Power Too LowWarning |
DC Power Too LowThis condition may occur at sunrise or sunset, while the modules are covered with snow, or during very bad weather. This event indicates that sunlight levels are too low for effective production. Once sunlight levels increase, the microinverter resumes power production and this event message will clear. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| DC Resistance LowCritical |
DC Resistance LowAn insulation resistance (IR) sensor in the microinverter measures the resistance between the positive and negative PV inputs to ground. If either resistance drops below a threshold, the microinverter raises this condition. This may indicate defective module insulation, defective wiring or connectors, moisture ingress, etc. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| DC Voltage Too HighFault |
DC Voltage Too HighThe microinverter reports that DC input voltage from the PV module is too high. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| DC Voltage Too LowWarning |
DC Voltage Too LowThe microinverter reports that DC input voltage from the PV module is too low. If this condition does not clear during hours of full daylight, the microinverters may be heavily shaded or covered by snow. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Download to module begunInfo |
Download to module begunThe Envoy has started a software upgrade to the indicated microinverter. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Download to module endedInfo |
Download to module endedThe Envoy has successfully delivered a software upgrade to a microinverter. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Download to module failedFault |
Download to module failedThe Envoy was unable to successfully deliver a software upgrade to a microinverter. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Envoy FailureFault |
Envoy FailureThis message displays after the Envoy has tried unsuccessfully three times to start up. This condition does not affect your system’s ability to produce power. When the connection is restored, the Envoy will catch up with the transmission of any/all energy data it has stored. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Filesystem integrity audit failedFault |
Filesystem integrity audit failedThe Envoy file system integrity audit has failed. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Grid Profile IncompatibleFault |
Grid Profile IncompatibleThis message displays when the selected grid profile is incompatible with microinverter software or hardware. This condition can affect your system’s ability to produce power. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Grid GoneFault |
Grid GoneThe microinverter has detected grid instability. In most cases, this points to a problem with the utility service (e.g., a power outage). In other cases, this may be a false positive and a microinverter may be incorrectly reporting grid instability. In this case a microinverter software upgrade may be needed to help resolve this issue. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Grid InstabilityFault |
Grid InstabilityThe microinverter is not producing power due to one or more of these conditions: AC Frequency Out Of Range, AC Voltage Out Of Range, or Grid Gone. Note that Grid Instability will remain for about five minutes after the underlying conditions clear. No power is produced during this time. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Grid Offset HiFault |
Grid Offset HiThe average current to the grid is too high for the configured grid profile. When the microinverter is operating normally, no DC current is injected into the grid. If the DC current is too high, this may indicate an issue with the microinverter. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Grid Offset LowFault |
Grid Offset LowThe average current to the grid is too low for the configured grid profile. When the microinverter is operating normally, no DC current is injected into the grid. If the DC current is too low (negative), this may indicate an issue with the microinverter. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Grid profile application completedInfo |
Grid profile application completedThe Envoy has completed a change to the grid profile for the microinverters. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| HardwareErrorFault |
HardwareErrorA hardware failure has occurred that prevents power conversion. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Module addedInfo |
Module addedThe Envoy has detected and is now associated to a new microinverter. No action is required. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Microinverter failed to reportFault |
Microinverter failed to reportThe Envoy reporting this condition is unable to communicate with the microinverters over the power lines. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Microinverter grid configuration failed after 5 attempts, retryingFault |
Microinverter grid configuration failed after 5 attempts, retryingThe attempt to change the grid profile for the microinverters has failed after five tries. The Envoy will continue to attempt to change the grid profile. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Microinverter grid configuration failure cleared after xx attemptsInfo |
Microinverter grid configuration failure cleared after xx attemptsA failed attempt to change the grid profile for the microinverters has cleared. The grid profile was successfully applied. xx = number of attempts What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Module SleepingInfo |
Module SleepingThe microinverter is off for the night. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| No Grid ProfileFault |
No Grid ProfileThe Envoy has not been set up with a grid profile for the microinverters. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Over TemperatureWarning |
Over TemperatureThe microinverter is too hot and is not producing power. This very rare condition usually clears without intervention. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Power generation off by commandInfo |
Power generation off by commandThe microinverter is not producing power by user command. This uncommon condition will occur only during isolated troubleshooting procedures by Enphase personnel. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Power On ResetInfo |
Power On ResetThe microinverter has powered on after having DC disconnected. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| ShutdownInfo |
ShutdownThe Envoy has been powered down (unplugged from AC power). What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| StartupInfo |
StartupThe Envoy has been powered back up (plugged back in to AC power). What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
| Transient Grid ProfileInfo |
Transient Grid ProfileThis system is currently in test mode. What you can do
Envoy gateway + M215/M250 microinverters (older, 50 Hz) · Guide only. All work must be done by a licensed electrician. |
No codes match. Try fewer characters, or ask us.
Common Enphase questions
What does Enphase Short red blinks at start-up "Start-up failure" mean?
Short red blinks after DC power is first applied indicate a failure during microinverter start-up. Note the code, time and whether it clears by itself This is a guide only; any electrical work must be done by a licensed electrician.
What does Enphase Bad Flash Image "Bad Flash Image" mean?
The microinverter is not producing power due to a software problem. Make sure the system is online so it can receive updates This is a guide only; any electrical work must be done by a licensed electrician.
What does Enphase DC Voltage Too High "DC Voltage Too High" mean?
The microinverter reports that DC input voltage from the PV module is too high. Check that your home Wi-Fi/internet is working and restart your router This is a guide only; any electrical work must be done by a licensed electrician.
What does Enphase Download to module failed "Download to module failed" mean?
The Envoy was unable to successfully deliver a software upgrade to a microinverter. Make sure the system is online so it can receive updates This is a guide only; any electrical work must be done by a licensed electrician.
What does Enphase Envoy Failure "Envoy Failure" mean?
This message displays after the Envoy has tried unsuccessfully three times to start up. This condition does not affect your system’s ability to produce power. When the connection is restored, the Envoy will catch up with the transmission of any/all energy data it has stored. Check that your home Wi-Fi/internet is working and restart your router This is a guide only; any electrical work must be done by a licensed electrician.
Need help with this fault?
Get a licensed electrician to call you back.
Total Solar can help: our licensed electricians install and service systems. Based in Ellenbrook, WA, with Victoria and Queensland also available.
Or call 1300 209 503
Sources
Meanings are summarised from these manufacturer documents. Check your own model's manual, as codes vary between models and firmware versions.
- Enphase IQ8 Series Microinverters Installation and Operation Manual (AU), IOM-00068-1.0, Jan 2024, section "Status LED indications and error reporting" p.26
- Enphase Envoy Communications Gateway Installation and Operation (50 Hz), 141-00014 Rev 04, "Event Messages" pp.46-51
Enphase is a trademark of its owner. Total Solar is not affiliated with the manufacturer unless stated. All fault code guides