iStore error codes explained
What 25 iStore inverter fault and error codes mean, in plain English, with safe checks you can do and when to call a licensed electrician.
Safety first: never open the switchboard, remove covers, or pull apart or disconnect the inverter, batteries, isolators or wiring. Only use the switches and buttons described here. Anything else must be done by a licensed electrician. Call 1300 209 503 or book a service request.
| Code | Message & meaning |
|---|---|
| 2001Fault |
High String Input VoltageThe PV array is not properly configured. Excessive PV modules are connected in series to the PV string, and therefore the open-circuit voltage exceeds the maximum inverter operating voltage. Cause ID = 1, 2 ⚫ 1: The PV1 input voltage is high. ⚫ 2: The PV2 input voltage is high. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2002Safety-Critical |
DC Arc FaultThe PV string power cables arc or are in poor contact. Cause ID = 1, 2 ⚫ 1: PV1 DC arc fault ⚫ 2: PV2 DC arc fault What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2003Safety-Critical |
DC arc faultThe PV string power cables arc or are in poor contact. ⚫ Cause ID 1 = PV1 ⚫ Cause ID 2 = PV2 ⚫ Cause ID 3 = PV3 …… What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2011Fault |
String ReversedThe PV string is reversely connected. Cause ID = 1, 2 ⚫ 1: PV1 is reversely connected. ⚫ 2: PV2 is reversely connected. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2021Safety-Critical |
AFCI Check FailureThe AFCI check fails. Cause ID = 1, 2 ⚫ 1: The AFCI check circuit is abnormal. ⚫ 2: The AFCI circuit is faulty. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2032Info |
Grid FailureCause ID = 1 ⚫ The power grid experiences an outage. ⚫ The AC circuit is disconnected or the AC circuit breaker is OFF. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2033Warning |
Grid UndervoltageCause ID = 1 The grid voltage is below the lower threshold or the low voltage duration has lasted for more than the value specified by low voltage ride-through (LVRT). What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2034Warning |
Grid OvervoltageCause ID = 1 The grid voltage exceeds the What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2036Warning |
Grid OverfrequencyCause ID = 1 Power grid exception: The actual power grid frequency is higher than the standard requirement for the local power grid. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2037Warning |
Grid UnderfrequencyCause ID = 1 Power grid exception: The actual power grid frequency is lower than the standard requirement for the local power grid. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2038Warning |
Unstable Grid FrequencyCause ID = 1 Power grid exception: The actual grid frequency change rate does not comply with the local power grid standard. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2039Warning |
Output OvercurrentCause ID = 1 The power grid voltage drops dramatically or the power grid is short-circuited. As a result, the inverter transient output current exceeds the upper threshold and therefore the inverter protection is triggered. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2040Fault |
Output DC Component OverhighCause ID = 1 The DC component of the inverter output current exceeds the specified upper threshold. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2051Safety-Critical |
Abnormal Residual CurrentCause ID = 1 The insulation impedance of the input side to PE decreases when the inverter is operating. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2062Safety-Critical |
Low Insulation ResistanceCause ID = 1 ⚫ A short circuit occurs between the PV array and the ground. ⚫ The ambient air of the PV array is damp and the insulation between the PV array and the ground is poor. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2063Warning |
OvertemperatureCause ID = 1 ⚫ The inverter is installed in a place with poor ventilation. ⚫ The ambient temperature is higher than the upper threshold. ⚫ The inverter is not working properly. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2064Safety-Critical |
Device FaultAn unrecoverable fault has occurred on a circuit inside the inverter. Cause ID = 1–12 ⚫ 1: The Boost input is short- circuited. ⚫ 2: The Boost input experiences overcurrent. ⚫ 3: The control circuit is faulty. ⚫ 4: The inverter circuit is abnormal. ⚫ 5: The residual current sensor is faulty. ⚫ 6: The temperature detection fails. ⚫ 7: EEPROM read/write fails. ⚫ 8: The auxiliary power supply is abnormal. ⚫ 9: The grid-tied relay is abnormal. ⚫ 10: The DC bus experiences overvoltage. ⚫ 11: The DC bus experiences undervoltage. ⚫ 12: The DC bus experiences voltage imbalance. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2065Warning |
Upgrade Failed or Version MismatchThe upgrade does not complete normally. Cause ID = 1–4, 7 ⚫ 1. The software and hardware of the main controller do not match. ⚫ 2: The main and auxiliary controller software versions do not match. ⚫ 3: The monitoring and power controller software versions do not match. ⚫ 4: The upgrade fails. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 61440Fault |
Monitoring Unit FaultyCause ID = 1 ⚫ The flash memory is insufficient. ⚫ The flash memory has bad sectors. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2067Fault |
Faulty Power CollectorCause ID = 1 The smart power sensor is disconnected. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2068Fault |
Battery AbnormalThe battery is faulty, disconnected, or the battery circuit breaker is OFF when the battery is running. Cause ID = 1–4 ⚫ 1: The battery communication is abnormal. ⚫ 2: The battery port experiences overcurrent. ⚫ 3. The battery enabling cable is not properly connected. ⚫ 4: The battery port voltage is abnormal. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2077Warning |
Off-grid output overloadCause ID = 1/2 The output is overloaded or short-circuited. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2080Fault |
Abnormal PV Module ConfigurationPV module configuration does not meet requirements, or the PV module output is reversely connected or short-circuited. Cause ID = 2, 3, 6, 7, 8, 9 ⚫ 2: The PV string power or the number of 3rd party optimizers connected in series in a PV string exceeds the upper threshold. ⚫ 3: The number of 3rd party optimizers connected in series in a PV string is less than the lower threshold, the PV string output is reversely connected, or the output of some optimizers in the PV string is reversely connected. ⚫ 6: Under the same MPPT, the number of 3rd party optimizers connected in series in PV strings con What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2081Fault |
3rd party optimizers FaultCause ID = 1 An optimizer is faulty. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
| 2082Warning |
Grid-tied/Off- grid Controller AbnormalCause ID = 1 The inverter fails to communicate with the Smart Backup Box. Cause ID = 2 An unrecoverable fault occurs on a circuit inside the Smart Backup Box. What you can do
IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician. |
No codes match. Try fewer characters, or ask us.
Common iStore questions
What does iStore 2001 "High String Input Voltage" mean?
The PV array is not properly configured. Excessive PV modules are connected in series to the PV string, and therefore the open-circuit voltage exceeds the maximum inverter operating voltage. Cause ID = 1, 2 ⚫ 1: The PV1 input voltage is high. ⚫ 2: The PV2 input voltage is high. Check solar generation in the app compared with similar days This is a guide only; any electrical work must be done by a licensed electrician.
What does iStore 2011 "String Reversed" mean?
The PV string is reversely connected. Cause ID = 1, 2 ⚫ 1: PV1 is reversely connected. ⚫ 2: PV2 is reversely connected. Do not touch the DC isolators, cables or connectors This is a guide only; any electrical work must be done by a licensed electrician.
What does iStore 2040 "Output DC Component Overhigh" mean?
Cause ID = 1 The DC component of the inverter output current exceeds the specified upper threshold. Restart the system once using the owner shutdown/start-up steps in your manual This is a guide only; any electrical work must be done by a licensed electrician.
What does iStore 61440 "Monitoring Unit Faulty" mean?
Cause ID = 1 ⚫ The flash memory is insufficient. ⚫ The flash memory has bad sectors. Note the code, date and time and check the monitoring app This is a guide only; any electrical work must be done by a licensed electrician.
What does iStore 2067 "Faulty Power Collector" mean?
Cause ID = 1 The smart power sensor is disconnected. Note the code, then restart the system once using the owner shutdown/start-up steps in your manual This is a guide only; any electrical work must be done by a licensed electrician.
Need help with this fault?
Get a licensed electrician to call you back.
Total Solar can help: our licensed electricians install and service systems. Based in Ellenbrook, WA, with Victoria and Queensland also available.