iStore error codes explained

What 25 iStore inverter fault and error codes mean, in plain English, with safe checks you can do and when to call a licensed electrician.

Guide only. This information is a general guide taken from manufacturer documentation. All electrical work must be performed by a licensed electrician. Never open your inverter, battery or switchboard. If you see smoke, smell burning or see damage, keep clear and call 000.
CodeMessage & meaningModelType
2001Fault
High String Input Voltage

The PV array is not properly configured. Excessive PV modules are connected in series to the PV string, and therefore the open-circuit voltage exceeds the maximum inverter operating voltage. Cause ID = 1, 2 ⚫ 1: The PV1 input voltage is high. ⚫ 2: The PV2 input voltage is high.

What you can do

  • Check solar generation in the app compared with similar days
  • Do not touch the DC isolators, cables or connectors, and don't go on the roof
  • If it doesn't clear by itself, call your installer

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2002Safety-Critical
DC Arc Fault

The PV string power cables arc or are in poor contact. Cause ID = 1, 2 ⚫ 1: PV1 DC arc fault ⚫ 2: PV2 DC arc fault

What you can do

  • Keep clear of the inverter, panels and DC cables, and do not touch any isolators
  • Note the code, date and time, and check whether the alarm is still showing in the app
  • If you smell burning or see smoke, get everyone out and call 000
  • Call a licensed electrician or Total Solar - an arc fault means a DC wiring or connector problem that must be inspected

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2003Safety-Critical
DC arc fault

The PV string power cables arc or are in poor contact. ⚫ Cause ID 1 = PV1 ⚫ Cause ID 2 = PV2 ⚫ Cause ID 3 = PV3 ……

What you can do

  • Keep clear of the inverter, panels and DC cables, and do not touch any isolators
  • Note the code, date and time, and check whether the alarm is still showing in the app
  • If you smell burning or see smoke, get everyone out and call 000
  • Call a licensed electrician or Total Solar - an arc fault means a DC wiring or connector problem that must be inspected

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2011Fault
String Reversed

The PV string is reversely connected. Cause ID = 1, 2 ⚫ 1: PV1 is reversely connected. ⚫ 2: PV2 is reversely connected.

What you can do

  • Do not touch the DC isolators, cables or connectors
  • Call your installer - this points to a wiring problem that needs a licensed electrician

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2021Safety-Critical
AFCI Check Failure

The AFCI check fails. Cause ID = 1, 2 ⚫ 1: The AFCI check circuit is abnormal. ⚫ 2: The AFCI circuit is faulty.

What you can do

  • Keep clear of the inverter, panels and DC cables, and do not touch any isolators
  • Note the code, date and time, and check whether the alarm is still showing in the app
  • If you smell burning or see smoke, get everyone out and call 000
  • Call a licensed electrician or Total Solar - an arc fault means a DC wiring or connector problem that must be inspected

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2032Info
Grid Failure

Cause ID = 1 ⚫ The power grid experiences an outage. ⚫ The AC circuit is disconnected or the AC circuit breaker is OFF.

What you can do

  • Check whether the rest of your house or street has power, and check your network operator's outage map
  • Check the switchboard for a tripped solar/inverter breaker - reset it once only; if it trips again, leave it off and call an electrician
  • Once normal power is back the inverter usually reconnects on its own within a few minutes
  • If the power is normal but the alarm stays, call your installer

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2033Warning
Grid Undervoltage

Cause ID = 1 The grid voltage is below the lower threshold or the low voltage duration has lasted for more than the value specified by low voltage ride-through (LVRT).

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2034Warning
Grid Overvoltage

Cause ID = 1 The grid voltage exceeds the

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2036Warning
Grid Overfrequency

Cause ID = 1 Power grid exception: The actual power grid frequency is higher than the standard requirement for the local power grid.

What you can do

  • This is caused by the mains frequency moving outside the allowed range, usually briefly
  • The inverter reconnects by itself once the grid is stable
  • If it keeps happening, note the times and call your installer

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2037Warning
Grid Underfrequency

Cause ID = 1 Power grid exception: The actual power grid frequency is lower than the standard requirement for the local power grid.

What you can do

  • This is caused by the mains frequency moving outside the allowed range, usually briefly
  • The inverter reconnects by itself once the grid is stable
  • If it keeps happening, note the times and call your installer

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2038Warning
Unstable Grid Frequency

Cause ID = 1 Power grid exception: The actual grid frequency change rate does not comply with the local power grid standard.

What you can do

  • This is caused by the mains frequency moving outside the allowed range, usually briefly
  • The inverter reconnects by itself once the grid is stable
  • If it keeps happening, note the times and call your installer

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2039Warning
Output Overcurrent

Cause ID = 1 The power grid voltage drops dramatically or the power grid is short-circuited. As a result, the inverter transient output current exceeds the upper threshold and therefore the inverter protection is triggered.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2040Fault
Output DC Component Overhigh

Cause ID = 1 The DC component of the inverter output current exceeds the specified upper threshold.

What you can do

  • Restart the system once using the owner shutdown/start-up steps in your manual
  • If it comes back, call your installer

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2051Safety-Critical
Abnormal Residual Current

Cause ID = 1 The insulation impedance of the input side to PE decreases when the inverter is operating.

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2062Safety-Critical
Low Insulation Resistance

Cause ID = 1 ⚫ A short circuit occurs between the PV array and the ground. ⚫ The ambient air of the PV array is damp and the insulation between the PV array and the ground is poor.

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2063Warning
Overtemperature

Cause ID = 1 ⚫ The inverter is installed in a place with poor ventilation. ⚫ The ambient temperature is higher than the upper threshold. ⚫ The inverter is not working properly.

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2064Safety-Critical
Device Fault

An unrecoverable fault has occurred on a circuit inside the inverter. Cause ID = 1–12 ⚫ 1: The Boost input is short- circuited. ⚫ 2: The Boost input experiences overcurrent. ⚫ 3: The control circuit is faulty. ⚫ 4: The inverter circuit is abnormal. ⚫ 5: The residual current sensor is faulty. ⚫ 6: The temperature detection fails. ⚫ 7: EEPROM read/write fails. ⚫ 8: The auxiliary power supply is abnormal. ⚫ 9: The grid-tied relay is abnormal. ⚫ 10: The DC bus experiences overvoltage. ⚫ 11: The DC bus experiences undervoltage. ⚫ 12: The DC bus experiences voltage imbalance.

What you can do

  • Keep clear and do not touch the inverter or cabling
  • Note the code, date and time
  • Call a licensed electrician or Total Solar - this alarm means current may be leaking to earth

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2065Warning
Upgrade Failed or Version Mismatch

The upgrade does not complete normally. Cause ID = 1–4, 7 ⚫ 1. The software and hardware of the main controller do not match. ⚫ 2: The main and auxiliary controller software versions do not match. ⚫ 3: The monitoring and power controller software versions do not match. ⚫ 4: The upgrade fails.

What you can do

  • Make sure the system is online so it can receive updates
  • Restart the system once using the owner steps in your manual
  • If the alarm stays, call your installer - settings and firmware must be fixed by them or the manufacturer

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
61440Fault
Monitoring Unit Faulty

Cause ID = 1 ⚫ The flash memory is insufficient. ⚫ The flash memory has bad sectors.

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2067Fault
Faulty Power Collector

Cause ID = 1 The smart power sensor is disconnected.

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2068Fault
Battery Abnormal

The battery is faulty, disconnected, or the battery circuit breaker is OFF when the battery is running. Cause ID = 1–4 ⚫ 1: The battery communication is abnormal. ⚫ 2: The battery port experiences overcurrent. ⚫ 3. The battery enabling cable is not properly connected. ⚫ 4: The battery port voltage is abnormal.

What you can do

  • Check the app - the battery may show as offline or with no state of charge
  • Restart the system once using the shutdown and start-up steps in your owner's manual (battery last off, first on, unless your manual says otherwise)
  • If the alarm comes back, call your installer - battery communication cables must be checked by them

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2077Warning
Off-grid output overload

Cause ID = 1/2 The output is overloaded or short-circuited.

What you can do

  • Turn off some large appliances (air-conditioners, ovens, kettles, pool pumps) - backup outputs have a power limit
  • The system usually recovers by itself once the load drops
  • If it keeps happening with normal loads, call your installer

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2080Fault
Abnormal PV Module Configuration

PV module configuration does not meet requirements, or the PV module output is reversely connected or short-circuited. Cause ID = 2, 3, 6, 7, 8, 9 ⚫ 2: The PV string power or the number of 3rd party optimizers connected in series in a PV string exceeds the upper threshold. ⚫ 3: The number of 3rd party optimizers connected in series in a PV string is less than the lower threshold, the PV string output is reversely connected, or the output of some optimizers in the PV string is reversely connected. ⚫ 6: Under the same MPPT, the number of 3rd party optimizers connected in series in PV strings con

What you can do

  • Do not touch the DC isolators, cables or connectors
  • Call your installer - this points to a wiring problem that needs a licensed electrician

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2081Fault
3rd party optimizers Fault

Cause ID = 1 An optimizer is faulty.

What you can do

  • Check solar generation in the app compared with similar days
  • Do not touch the DC isolators, cables or connectors, and don't go on the roof
  • If it doesn't clear by itself, call your installer

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter
2082Warning
Grid-tied/Off- grid Controller Abnormal

Cause ID = 1 The inverter fails to communicate with the Smart Backup Box. Cause ID = 2 An unrecoverable fault occurs on a circuit inside the Smart Backup Box.

What you can do

  • Check that your home Wi-Fi/internet is working and restart your router
  • Wait an hour - monitoring often reconnects by itself
  • If the inverter screen also shows a fault, or the alarm stays for more than a day, call your installer

IS-HYB-5000/6000-1PH single-phase hybrid · Guide only. All work must be done by a licensed electrician.

IS-HYB-5000/6000-1PH single-phase hybrid Inverter

Common iStore questions

What does iStore 2001 "High String Input Voltage" mean?

The PV array is not properly configured. Excessive PV modules are connected in series to the PV string, and therefore the open-circuit voltage exceeds the maximum inverter operating voltage. Cause ID = 1, 2 ⚫ 1: The PV1 input voltage is high. ⚫ 2: The PV2 input voltage is high. Check solar generation in the app compared with similar days This is a guide only; any electrical work must be done by a licensed electrician.

What does iStore 2011 "String Reversed" mean?

The PV string is reversely connected. Cause ID = 1, 2 ⚫ 1: PV1 is reversely connected. ⚫ 2: PV2 is reversely connected. Do not touch the DC isolators, cables or connectors This is a guide only; any electrical work must be done by a licensed electrician.

What does iStore 2040 "Output DC Component Overhigh" mean?

Cause ID = 1 The DC component of the inverter output current exceeds the specified upper threshold. Restart the system once using the owner shutdown/start-up steps in your manual This is a guide only; any electrical work must be done by a licensed electrician.

What does iStore 61440 "Monitoring Unit Faulty" mean?

Cause ID = 1 ⚫ The flash memory is insufficient. ⚫ The flash memory has bad sectors. Note the code, date and time and check the monitoring app This is a guide only; any electrical work must be done by a licensed electrician.

What does iStore 2067 "Faulty Power Collector" mean?

Cause ID = 1 The smart power sensor is disconnected. Note the code, then restart the system once using the owner shutdown/start-up steps in your manual This is a guide only; any electrical work must be done by a licensed electrician.

Need help with this fault?

Get a licensed electrician to call you back.

Total Solar can help: our licensed electricians install and service systems. Based in Ellenbrook, WA, with Victoria and Queensland also available.

Or call 1300 209 503