KACO error codes explained

What 53 KACO inverter fault and error codes mean, in plain English, with safe checks you can do and when to call a licensed electrician.

Guide only. This information is a general guide taken from manufacturer documentation. All electrical work must be performed by a licensed electrician. Never open your inverter, battery or switchboard. If you see smoke, smell burning or see damage, keep clear and call 000.
CodeMessage & meaningModelType
OS 1Info
Waiting for feed-in

Self-test: the grid parameters and solar (generator) voltage are being checked.

What you can do

  • No action needed - this is a status message, not a fault
  • If it stays for a long time or the system isn't producing when it should, call your installer

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
OS 2Warning
Generator voltage is too low

Not enough solar voltage and power - normal status before the inverter switches off for the night.

What you can do

  • This is normal at dawn, dusk, in heavy cloud or when panels are shaded
  • No action needed if it clears once the sun is up
  • If it shows in full sun, call your installer

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
OS 8Info
Self-test

The inverter is checking its power electronics and grid relay before feeding in.

What you can do

  • No action needed - this is a status message, not a fault
  • If it stays for a long time or the system isn't producing when it should, call your installer

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 10Fault
Temperature in unit too high

The inverter has switched off because it overheated. Possible causes: very high ambient temperature, fan covered, or inverter defective.

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
OS 11Info
Measured values (power limitation)

Power limitation: the solar generator power is too high so the inverter limits itself to its maximum power (e.g. around noon).

What you can do

  • No action needed - this is a status message, not a fault
  • If it stays for a long time or the system isn't producing when it should, call your installer

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 17Fault
Shutting down Powador-protect

The activated grid and system protection has been tripped.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 18Critical
Resid. current shutdown

Residual current was detected and feed-in was interrupted.

What you can do

  • Keep clear and do not touch the inverter or cabling
  • Note the code, date and time
  • If you see smoke, smell burning or hear crackling, keep everyone away and call 000
  • Call a licensed electrician or Total Solar - this alarm means current may be leaking to earth

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 19Critical
Insulation fault

There is an insulation fault on the PV generator. The feed-in was interrupted.

What you can do

  • Keep clear - do not touch the panels, rooftop isolators, DC cables or the inverter
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If you see smoke, smell burning or hear crackling, keep everyone away and call 000
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 21Fault
Protective shutdown PV current 1

DC current has exceeded the permissible maximum on PV input 1. The inverter shut down to protect itself.

What you can do

  • Do not touch the DC isolators or cables
  • Note the time - this often shows on cold, very sunny mornings
  • Call your installer - the panel strings may need to be checked against the inverter's limits

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 22Fault
Protective shutdown PV current 2

DC current has exceeded the permissible maximum on PV input 2. The inverter shut down to protect itself.

What you can do

  • Do not touch the DC isolators or cables
  • Note the time - this often shows on cold, very sunny mornings
  • Call your installer - the panel strings may need to be checked against the inverter's limits

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 23Fault
Protective shutdown PV current 3

DC current has exceeded the permissible maximum on PV input 3. The inverter shut down to protect itself.

What you can do

  • Do not touch the DC isolators or cables
  • Note the time - this often shows on cold, very sunny mornings
  • Call your installer - the panel strings may need to be checked against the inverter's limits

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 29Critical
Ground connection check fuse

A ground fault was detected at the PV generator.

What you can do

  • Keep clear - do not touch the inverter, frames or cabling
  • Leave the system off if it has shut down
  • If you see smoke, smell burning or hear crackling, keep everyone away and call 000
  • Call a licensed electrician or Total Solar to test the earthing

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 32Fault
Fault self-test

The internal grid separation relay test has failed.

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 33Fault
DC feed-in error

The DC component fed into the grid has exceeded the permitted value.

What you can do

  • Restart the system once using the owner shutdown/start-up steps in your manual
  • If it comes back, call your installer

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 35Fault
Protection shutdown SW

Software protective shutdown (AC overvoltage, AC overcurrent, DC link overvoltage, DC overvoltage, DC overtemperature). Grid-related; the inverter reconnects automatically.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 37Fault
Unknown hardware

Hardware was connected that is not compatible with this device or has not been connected properly.

What you can do

  • Note the code, time and whether it clears by itself
  • You may restart the system once using the owner shutdown/start-up steps in your manual. Do not open covers or touch cabling
  • If the code returns or the system stays offline, call your installer - internal faults are a warranty/technician job

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 38Fault
Generator overvoltage error

The voltage of the solar (DC) generator is too high - the PV generator is configured incorrectly.

What you can do

  • Do not touch the DC isolators or cables
  • Note the time - this often shows on cold, very sunny mornings
  • Call your installer - the panel strings may need to be checked against the inverter's limits

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 41Fault
Line failure: undervoltage L1

The voltage on grid phase L1 is too low; the inverter cannot feed in.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 42Fault
Line failure: overvoltage L1

The voltage on grid phase L1 is too high; the inverter cannot feed in.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 43Fault
Line failure: undervoltage L2

The voltage on grid phase L2 is too low; the inverter cannot feed in.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 44Fault
Line failure: overvoltage L2

The voltage on grid phase L2 is too high; the inverter cannot feed in.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 45Fault
Line failure: undervoltage L3

The voltage on grid phase L3 is too low; the inverter cannot feed in.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 46Fault
Line failure: overvoltage L3

The voltage on grid phase L3 is too high; the inverter cannot feed in.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 47Fault
Grid failure phase-to-phase voltage

The measured line-to-line voltage is outside the tolerance limits.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 48Fault
Line failure underfrequency

Grid frequency is too low. This fault may be grid-related.

What you can do

  • This is caused by the mains frequency moving outside the allowed range, usually briefly
  • The inverter reconnects by itself once the grid is stable
  • If it keeps happening, note the times and call your installer

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 49Fault
Line failure overfrequency

Grid frequency is too high. This fault may be grid-related.

What you can do

  • This is caused by the mains frequency moving outside the allowed range, usually briefly
  • The inverter reconnects by itself once the grid is stable
  • If it keeps happening, note the times and call your installer

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 50Fault
Line failure average voltage

The grid voltage measured per EN 50160 has exceeded the maximum permitted limit. This fault may be grid-related.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 56Info
Switch off via digital input

The inverter was disconnected from the grid by a remote command (remote trip-off).

What you can do

  • No action needed - this is a status message, not a fault
  • If it stays for a long time or the system isn't producing when it should, call your installer

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 57Info
Waiting for reconnect

The inverter is waiting after a fault; it will not switch on again until the country-specific time has passed.

What you can do

  • No action needed - this is a status message, not a fault
  • If it stays for a long time or the system isn't producing when it should, call your installer

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 58Fault
Overtemperature control card

The temperature inside the unit was too high. The inverter switches off to prevent damage.

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
OS 60Fault
Generator voltage too high

The inverter won't start feeding in until the solar voltage falls below a set value.

What you can do

  • Do not touch the DC isolators or cables
  • Note the time - this often shows on cold, very sunny mornings
  • Call your installer - the panel strings may need to be checked against the inverter's limits

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
OS 61Info
External limit (%)

External power limit activated by the system controller; the inverter limits its power.

What you can do

  • No action needed - this is a status message, not a fault
  • If it stays for a long time or the system isn't producing when it should, call your installer

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
OS 63Info
Measured values P(f)

Frequency-dependent power reduction is active (starts at 50.2 Hz).

What you can do

  • No action needed - this is a status message, not a fault
  • If it stays for a long time or the system isn't producing when it should, call your installer

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
OS 64Info
Measured values (output current limiting)

The AC output current is being limited at its specified maximum.

What you can do

  • No action needed - this is a status message, not a fault
  • If it stays for a long time or the system isn't producing when it should, call your installer

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 70Fault
Fan error

The fan is malfunctioning.

What you can do

  • From outside, check that nothing is blocking the vents
  • Don't open the unit
  • Call your installer to arrange a fan check or replacement

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 71Fault
Fan error (external)

The external fan is malfunctioning.

What you can do

  • From outside, check that nothing is blocking the vents
  • Don't open the unit
  • Call your installer to arrange a fan check or replacement

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 73Fault
Standalone grid err.

Standalone (islanding) mode was detected.

What you can do

  • Check whether the rest of your house or street has power, and check your network operator's outage map
  • Check the switchboard for a tripped solar/inverter breaker - reset it once only; if it trips again, leave it off and call an electrician
  • Once normal power is back the inverter usually reconnects on its own within a few minutes
  • If the power is normal but the alarm stays, call your installer

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 78Critical
Resid. current shutdown (AFI)

Measured residual (AFI) fault current was above 180 mA; the device switched off immediately.

What you can do

  • Keep clear and do not touch the inverter or cabling
  • Note the code, date and time
  • If you see smoke, smell burning or hear crackling, keep everyone away and call 000
  • Call a licensed electrician or Total Solar - this alarm means current may be leaking to earth

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 80Fault
Insulation meas. not possible

The insulation measurement can't be done because the solar voltage is too unsteady.

What you can do

  • This is normal at dawn, dusk, in heavy cloud or when panels are shaded
  • No action needed if it clears once the sun is up
  • If it shows in full sun, call your installer

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 81Fault
Protection shutdown line volt. L1

Overvoltage detected on conductor L1; an internal protection disconnected the device.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 82Fault
Protection shutdown line volt. L2

Overvoltage detected on conductor L2; an internal protection disconnected the device.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 83Fault
Protection shutdown line volt. L3

Overvoltage detected on conductor L3; an internal protection disconnected the device.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 84Fault
Protection shutdown undervolt. DC link

A voltage deviation was found in the internal DC link; an internal protection disconnected the device.

What you can do

  • Note the code, time and whether it clears by itself
  • You may restart the system once using the owner shutdown/start-up steps in your manual. Do not open covers or touch cabling
  • If the code returns or the system stays offline, call your installer - internal faults are a warranty/technician job

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 85Fault
Protect. shutdown overvolt. DC link

Overvoltage in the internal DC link; an internal protection disconnected the device.

What you can do

  • Note the code, time and whether it clears by itself
  • You may restart the system once using the owner shutdown/start-up steps in your manual. Do not open covers or touch cabling
  • If the code returns or the system stays offline, call your installer - internal faults are a warranty/technician job

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 87Fault
Protection shutdown overcurrent L1

Current on conductor L1 too high; an internal protection disconnected the device.

What you can do

  • Note the code, time and whether it clears by itself
  • You may restart the system once using the owner shutdown/start-up steps in your manual. Do not open covers or touch cabling
  • If the code returns or the system stays offline, call your installer - internal faults are a warranty/technician job

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 88Fault
Protection shutdown overcurrent L2

Current on conductor L2 too high; an internal protection disconnected the device.

What you can do

  • Note the code, time and whether it clears by itself
  • You may restart the system once using the owner shutdown/start-up steps in your manual. Do not open covers or touch cabling
  • If the code returns or the system stays offline, call your installer - internal faults are a warranty/technician job

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 89Fault
Protection shutdown overcurrent L3

Current on conductor L3 too high; an internal protection disconnected the device.

What you can do

  • Note the code, time and whether it clears by itself
  • You may restart the system once using the owner shutdown/start-up steps in your manual. Do not open covers or touch cabling
  • If the code returns or the system stays offline, call your installer - internal faults are a warranty/technician job

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 91Fault
Protect. shutdown drop 2.5V

Internal 2.5 V reference voltage outside the permissible range.

What you can do

  • Note the code, time and whether it clears by itself
  • You may restart the system once using the owner shutdown/start-up steps in your manual. Do not open covers or touch cabling
  • If the code returns or the system stays offline, call your installer - internal faults are a warranty/technician job

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 92Fault
Protect. shutdown drop 1.5V

Internal 1.5 V reference voltage outside the permissible range.

What you can do

  • Note the code, time and whether it clears by itself
  • You may restart the system once using the owner shutdown/start-up steps in your manual. Do not open covers or touch cabling
  • If the code returns or the system stays offline, call your installer - internal faults are a warranty/technician job

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 97Fault
Protection shutdown overcurrent HW

Too much power was fed into the grid; complete disconnection of the device.

What you can do

  • Note the code, time and whether it clears by itself
  • You may restart the system once using the owner shutdown/start-up steps in your manual. Do not open covers or touch cabling
  • If the code returns or the system stays offline, call your installer - internal faults are a warranty/technician job

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 100Fault
Protect. shutdown HW overheating

The device switched off because the temperatures in the housing were too high.

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 101-106Fault
Plausibility error (temperature, efficiency, DC link, AFI module, relay, DC/DC converter)

The unit shut down because of implausible internal measured values.

What you can do

  • Note the code, time and whether it clears by itself
  • You may restart the system once using the owner shutdown/start-up steps in your manual. Do not open covers or touch cabling
  • If the code returns or the system stays offline, call your installer - internal faults are a warranty/technician job

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter
FS 108-113Fault
Critical overvoltage/undervoltage L1-L3

Grid voltage is outside the upper limits on the indicated phase.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

blueplanet 5.0-10.0 TL3 three-phase · Guide only. All work must be done by a licensed electrician.

blueplanet 5.0-10.0 TL3 three-phase Inverter

Common KACO questions

What does KACO FS 10 "Temperature in unit too high" mean?

The inverter has switched off because it overheated. Possible causes: very high ambient temperature, fan covered, or inverter defective. Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents This is a guide only; any electrical work must be done by a licensed electrician.

What does KACO FS 17 "Shutting down Powador-protect" mean?

The activated grid and system protection has been tripped. This is usually caused by the mains supply, not the solar system This is a guide only; any electrical work must be done by a licensed electrician.

What does KACO FS 21 "Protective shutdown PV current 1" mean?

DC current has exceeded the permissible maximum on PV input 1. The inverter shut down to protect itself. Do not touch the DC isolators or cables This is a guide only; any electrical work must be done by a licensed electrician.

What does KACO FS 22 "Protective shutdown PV current 2" mean?

DC current has exceeded the permissible maximum on PV input 2. The inverter shut down to protect itself. Do not touch the DC isolators or cables This is a guide only; any electrical work must be done by a licensed electrician.

What does KACO FS 23 "Protective shutdown PV current 3" mean?

DC current has exceeded the permissible maximum on PV input 3. The inverter shut down to protect itself. Do not touch the DC isolators or cables This is a guide only; any electrical work must be done by a licensed electrician.

Need help with this fault?

Get a licensed electrician to call you back.

Total Solar can help: our licensed electricians install and service systems. Based in Ellenbrook, WA, with Victoria and Queensland also available.

Or call 1300 209 503

By sending this form you agree to Total Solar (THK Group Pty Ltd) contacting you by phone, SMS or email about this request. We use your details only to respond, as set out in our Privacy Policy.

Sources

Meanings are summarised from these manufacturer documents. Check your own model's manual, as codes vary between models and firmware versions.

KACO is a trademark of its owner. Total Solar is not affiliated with the manufacturer unless stated. All fault code guides

Get a quote Call