SAJ R6 3-15K-T2 three-phase string error codes explained

What 75 SAJ R6 3-15K-T2 three-phase string inverter & battery fault and error codes mean, in plain English, with safe checks you can do and when to call a licensed electrician.

Guide only. This information is a general guide taken from manufacturer documentation. All electrical work must be performed by a licensed electrician. Never open your inverter, battery or switchboard. If you see smoke, smell burning or see damage, keep clear and call 000.
CodeMessage & meaningModelType
1Fault
Master Relay Error

Master Relay Error

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
2Fault
Master EEPROM Error

Master EEPROM Error

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
3Warning
Master Temperature High Error

Master Temperature High Error

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
4Warning
Master Temperature Low Error

Master Temperature Low Error

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
5Warning
Lost Communication M<->S

Lost Communication M<->S

What you can do

  • Check that your home Wi-Fi/internet is working and restart your router
  • Wait an hour - monitoring often reconnects by itself
  • If the inverter screen also shows a fault, or the alarm stays for more than a day, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
6Safety-Critical
GFCI Device Error

GFCI Device Error

What you can do

  • Keep clear and do not touch the inverter or cabling
  • Note the code, date and time
  • Call a licensed electrician or Total Solar - this alarm means current may be leaking to earth

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
7Fault
DCI Device Error

DCI Device Error

What you can do

  • Restart the system once using the owner shutdown/start-up steps in your manual
  • If it comes back, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
8Fault
Current Sensor Error

Current Sensor Error

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
9Warning
Master Phase1 Voltage High

Master Phase1 Voltage High

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
10Warning
Master Phase1 Voltage Low

Master Phase1 Voltage Low

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
11Warning
Master Phase2 Voltage High

Master Phase2 Voltage High

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
12Warning
Master Phase2 Voltage Low

Master Phase2 Voltage Low

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
13Warning
Master Phase3 Voltage High

Master Phase3 Voltage High

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
14Warning
Master Phase3 Voltage Lo w

Master Phase3 Voltage Lo w

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
15Warning
Grid Voltage 10Min High

Grid Voltage 10Min High

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
16Warning
OGrid Output Voltage Low

OGrid Output Voltage Low

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
17Fault
OGrid Output Sho Circuit

OGrid Output Sho Circuit

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
18Warning
Master Grid Frequency High

Master Grid Frequency High

What you can do

  • This is caused by the mains frequency moving outside the allowed range, usually briefly
  • The inverter reconnects by itself once the grid is stable
  • If it keeps happening, note the times and call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
19Warning
Master Grid Frequency Low

Master Grid Frequency Low

What you can do

  • This is caused by the mains frequency moving outside the allowed range, usually briefly
  • The inverter reconnects by itself once the grid is stable
  • If it keeps happening, note the times and call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
21Fault
Phase1 DCV High

Phase1 DCV High

What you can do

  • Restart the system once using the owner shutdown/start-up steps in your manual
  • If it comes back, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
22Fault
Phase2 DCV High

Phase2 DCV High

What you can do

  • Restart the system once using the owner shutdown/start-up steps in your manual
  • If it comes back, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
23Fault
Phase3 DCV High

Phase3 DCV High

What you can do

  • Restart the system once using the owner shutdown/start-up steps in your manual
  • If it comes back, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
24Info
Master No Grid Error

Master No Grid Error

What you can do

  • Check whether the rest of your house or street has power, and check your network operator's outage map
  • Check the switchboard for a tripped solar/inverter breaker - reset it once only; if it trips again, leave it off and call an electrician
  • Once normal power is back the inverter usually reconnects on its own within a few minutes
  • If the power is normal but the alarm stays, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
27Safety-Critical
GFCI Error

GFCI Error

What you can do

  • Keep clear and do not touch the inverter or cabling
  • Note the code, date and time
  • Call a licensed electrician or Total Solar - this alarm means current may be leaking to earth

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
28Fault
Phase1 DCI Error

Phase1 DCI Error

What you can do

  • Restart the system once using the owner shutdown/start-up steps in your manual
  • If it comes back, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
29Fault
Phase2 DCI Error

Phase2 DCI Error

What you can do

  • Restart the system once using the owner shutdown/start-up steps in your manual
  • If it comes back, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
30Fault
Phase3 DCI Error

Phase3 DCI Error

What you can do

  • Restart the system once using the owner shutdown/start-up steps in your manual
  • If it comes back, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
31Safety-Critical
ISO Error

ISO Error

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
32Warning
Bus Voltage Balance Error

Bus Voltage Balance Error

What you can do

  • Check that your home Wi-Fi/internet is working and restart your router
  • Wait an hour - monitoring often reconnects by itself
  • If the inverter screen also shows a fault, or the alarm stays for more than a day, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
33Fault
Master Bus Voltage High

Master Bus Voltage High

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
34Fault
Master Bus Voltage Low

Master Bus Voltage Low

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
35Fault
Master Grid Phase Lost

Master Grid Phase Lost

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
36Fault
Master PV Voltage High

Master PV Voltage High

What you can do

  • Do not touch the DC isolators or cables
  • Note the time - this often shows on cold, very sunny mornings
  • Call your installer - the panel strings may need to be checked against the inverter's limits

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
37Info
Master Islanding Error

Master Islanding Error

What you can do

  • Check whether the rest of your house or street has power, and check your network operator's outage map
  • Check the switchboard for a tripped solar/inverter breaker - reset it once only; if it trips again, leave it off and call an electrician
  • Once normal power is back the inverter usually reconnects on its own within a few minutes
  • If the power is normal but the alarm stays, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
38Fault
Master HW Bus Voltage High

Master HW Bus Voltage High

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
39Fault
Master HW PV Current High

Master HW PV Current High

What you can do

  • Check solar generation in the app compared with similar days
  • Do not touch the DC isolators, cables or connectors, and don't go on the roof
  • If it doesn't clear by itself, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
40Fault
Master Self-Test Failed

Master Self-Test Failed

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
41Fault
Master HW Inv Current High

Master HW Inv Current High

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
42Fault
Master AC SPD Error

Master AC SPD Error

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
43Fault
Master DC SPD Error

Master DC SPD Error

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
44Warning
Master Grid NE Voltage Error

Master Grid NE Voltage Error

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
45Warning
Master Fan1 Error

Master Fan1 Error

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
46Warning
Master Fan2 Error

Master Fan2 Error

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
47Warning
Master Fan3 Error

Master Fan3 Error

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
48Warning
Master Fan4 Error

Master Fan4 Error

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
49Warning
Lost Communication between Master and Meter

Lost Communication between Master and Meter

What you can do

  • Check the monitoring app for the alarm and whether export/consumption readings look wrong
  • Restart your home router if the meter talks over Wi-Fi or LAN
  • Call your installer - meter and CT wiring is inside the switchboard and must be checked by a licensed electrician

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
50Warning
Lost Communication between M< ->S

Lost Communication between M< ->S

What you can do

  • Check that your home Wi-Fi/internet is working and restart your router
  • Wait an hour - monitoring often reconnects by itself
  • If the inverter screen also shows a fault, or the alarm stays for more than a day, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
51Warning
Lost Communication between inveer and SEC

Lost Communication between inveer and SEC

What you can do

  • Check that your home Wi-Fi/internet is working and restart your router
  • Wait an hour - monitoring often reconnects by itself
  • If the inverter screen also shows a fault, or the alarm stays for more than a day, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
52Fault
HMI EEPROM Error

HMI EEPROM Error

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
53Fault
HMI RTC Error

HMI RTC Error

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
54Fault
BMS Device Error

BMS Device Error

What you can do

  • Check the battery status and any extra alarms in the app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If the alarm comes back, or the battery is hot, swollen, noisy or smells, keep clear and call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
55Fault
BMS Lost.Conn

BMS Lost.Conn

What you can do

  • Check the app - the battery may show as offline or with no state of charge
  • Restart the system once using the shutdown and start-up steps in your owner's manual (battery last off, first on, unless your manual says otherwise)
  • If the alarm comes back, call your installer - battery communication cables must be checked by them

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
56Warning
CT Device Err

CT Device Err

What you can do

  • Check the monitoring app for the alarm and whether export/consumption readings look wrong
  • Restart your home router if the meter talks over Wi-Fi or LAN
  • Call your installer - meter and CT wiring is inside the switchboard and must be checked by a licensed electrician

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
57Safety-Critical
AFCI Lost Err

AFCI Lost Err

What you can do

  • Keep clear of the inverter, panels and DC cables, and do not touch any isolators
  • Note the code, date and time, and check whether the alarm is still showing in the app
  • If you smell burning or see smoke, get everyone out and call 000
  • Call a licensed electrician or Total Solar - an arc fault means a DC wiring or connector problem that must be inspected

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
58Warning
Lost Com. H<->S Err

Lost Com. H<->S Err

What you can do

  • Check that your home Wi-Fi/internet is working and restart your router
  • Wait an hour - monitoring often reconnects by itself
  • If the inverter screen also shows a fault, or the alarm stays for more than a day, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
61Warning
Slave Phase1 Voltage High

Slave Phase1 Voltage High

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
62Warning
Slave Phase1 Voltage Low

Slave Phase1 Voltage Low

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
63Warning
Slave Phase2 Voltage High

Slave Phase2 Voltage High

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
64Warning
Slave Phase2 Voltage Low

Slave Phase2 Voltage Low

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
65Warning
Slave Phase3 Voltage High

Slave Phase3 Voltage High

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
66Warning
Slave Phase3 Voltage Low

Slave Phase3 Voltage Low

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
67Warning
Slave Frequency High

Slave Frequency High

What you can do

  • This is caused by the mains frequency moving outside the allowed range, usually briefly
  • The inverter reconnects by itself once the grid is stable
  • If it keeps happening, note the times and call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
68Warning
Slave Frequency Low

Slave Frequency Low

What you can do

  • This is caused by the mains frequency moving outside the allowed range, usually briefly
  • The inverter reconnects by itself once the grid is stable
  • If it keeps happening, note the times and call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
73Info
Slave No Grid Error

Slave No Grid Error

What you can do

  • Check whether the rest of your house or street has power, and check your network operator's outage map
  • Check the switchboard for a tripped solar/inverter breaker - reset it once only; if it trips again, leave it off and call an electrician
  • Once normal power is back the inverter usually reconnects on its own within a few minutes
  • If the power is normal but the alarm stays, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
74Fault
PVInputModeFault

PVInputModeFault

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
75Fault
HWPVCurrHighFault

HWPVCurrHighFault

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
76Fault
Slave PV Voltage High

Slave PV Voltage High

What you can do

  • Do not touch the DC isolators or cables
  • Note the time - this often shows on cold, very sunny mornings
  • Call your installer - the panel strings may need to be checked against the inverter's limits

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
77Fault
Slave HW Bus Volt High

Slave HW Bus Volt High

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
81Warning
Lost Communication D< ->C

Lost Communication D< ->C

What you can do

  • Check that your home Wi-Fi/internet is working and restart your router
  • Wait an hour - monitoring often reconnects by itself
  • If the inverter screen also shows a fault, or the alarm stays for more than a day, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
83Safety-Critical
Master Arc Device Error

Master Arc Device Error

What you can do

  • Keep clear of the inverter, panels and DC cables, and do not touch any isolators
  • Note the code, date and time, and check whether the alarm is still showing in the app
  • If you smell burning or see smoke, get everyone out and call 000
  • Call a licensed electrician or Total Solar - an arc fault means a DC wiring or connector problem that must be inspected

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
84Fault
Master PV Mode Error

Master PV Mode Error

What you can do

  • Check solar generation in the app compared with similar days
  • Do not touch the DC isolators, cables or connectors, and don't go on the roof
  • If it doesn't clear by itself, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
85Fault
Authority expires

Authority expires

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
86Fault
DRM0 Error

DRM0 Error

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
87Safety-Critical
Master Arc Error

Master Arc Error

What you can do

  • Keep clear of the inverter, panels and DC cables, and do not touch any isolators
  • Note the code, date and time, and check whether the alarm is still showing in the app
  • If you smell burning or see smoke, get everyone out and call 000
  • Call a licensed electrician or Total Solar - an arc fault means a DC wiring or connector problem that must be inspected

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter
88Fault
Master SW PV Current High

Master SW PV Current High

What you can do

  • Check solar generation in the app compared with similar days
  • Do not touch the DC isolators, cables or connectors, and don't go on the roof
  • If it doesn't clear by itself, call your installer

R6 3-15K-T2 three-phase string · Guide only. All work must be done by a licensed electrician.

R6 3-15K-T2 three-phase string Inverter

Need help with this fault?

Get a licensed electrician to call you back.

Total Solar can help: our licensed electricians install and service systems. Based in Ellenbrook, WA, with Victoria and Queensland also available.

Or call 1300 209 503

By sending this form you agree to Total Solar (THK Group Pty Ltd) contacting you by phone, SMS or email about this request. We use your details only to respond, as set out in our Privacy Policy.

Sources

Meanings are summarised from these manufacturer documents. Check your own model's manual, as codes vary between models and firmware versions.

SAJ is a trademark of its owner. Total Solar is not affiliated with the manufacturer unless stated. All fault code guides

Get a quote Call