Sungrow error codes explained

What 31 Sungrow inverter fault and error codes mean, in plain English, with safe checks you can do and when to call a licensed electrician.

Guide only. This information is a general guide taken from manufacturer documentation. All electrical work must be performed by a licensed electrician. Never open your inverter, battery or switchboard. If you see smoke, smell burning or see damage, keep clear and call 000.
CodeMessage & meaningModelType
2, 3, 14, 15Warning
Grid Overvoltage

Grid Overvoltage

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
4, 5Warning
Grid Undervoltage

Grid Undervoltage

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
8, 9Warning
Grid Overfrequency / Grid Underfrequency

Grid Overfrequency Grid Underfrequency

What you can do

  • This is caused by the mains frequency moving outside the allowed range, usually briefly
  • The inverter reconnects by itself once the grid is stable
  • If it keeps happening, note the times and call your installer

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
10Info
Grid Power Outage

Grid Power Outage

What you can do

  • Check whether the rest of your house or street has power, and check your network operator's outage map
  • Check the switchboard for a tripped solar/inverter breaker - reset it once only; if it trips again, leave it off and call an electrician
  • Once normal power is back the inverter usually reconnects on its own within a few minutes
  • If the power is normal but the alarm stays, call your installer

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
12Safety-Critical
Excess Leakage Current

Excess Leakage Current

What you can do

  • Keep clear and do not touch the inverter or cabling
  • Note the code, date and time
  • Call a licensed electrician or Total Solar - this alarm means current may be leaking to earth

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
13Warning
Grid Abnormal

Grid Abnormal

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
17Warning
Grid Voltage Imbalance

Grid Voltage Imbalance

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
28, 29, 208, 212, 448-479Fault
PV Reverse Connection Fault

PV Reverse Connection Fault

What you can do

  • Do not touch the DC isolators, cables or connectors
  • Call your installer - this points to a wiring problem that needs a licensed electrician

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
532-547, 564-579Fault
PV Reverse Connection Alarm

PV Reverse Connection Alarm

What you can do

  • Do not touch the DC isolators, cables or connectors
  • Call your installer - this points to a wiring problem that needs a licensed electrician

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
548-563, 580-595Fault
PV Abnormal Alarm

PV Abnormal Alarm

What you can do

  • Check solar generation in the app compared with similar days
  • Do not touch the DC isolators, cables or connectors, and don't go on the roof
  • If it doesn't clear by itself, call your installer

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
37Warning
Excessively High Ambient Temperature

Excessively High Ambient Temperature

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
43Warning
Excessively Low Ambient Temperature

Excessively Low Ambient Temperature

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
39Safety-Critical
Low System Insulation Resistance

Low System Insulation Resistance

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
106Safety-Critical
Grounding Cable Fault

Grounding Cable Fault

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
88Safety-Critical
Electric Arc Fault

Electric Arc Fault

What you can do

  • Keep clear of the inverter, panels and DC cables, and do not touch any isolators
  • Note the code, date and time, and check whether the alarm is still showing in the app
  • If you smell burning or see smoke, get everyone out and call 000
  • Call a licensed electrician or Total Solar - an arc fault means a DC wiring or connector problem that must be inspected

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
51Warning
Off-Grid Load OverPower Fault

Off-Grid Load OverPower Fault

What you can do

  • Turn off some large appliances (air-conditioners, ovens, kettles, pool pumps) - backup outputs have a power limit
  • The system usually recovers by itself once the load drops
  • If it keeps happening with normal loads, call your installer

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
323Warning
Grid Confrontation

Grid Confrontation

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
75Warning
Inverter Parallel Communication Alarm

Inverter Parallel Communication Alarm

What you can do

  • Check that your home Wi-Fi/internet is working and restart your router
  • Wait an hour - monitoring often reconnects by itself
  • If the inverter screen also shows a fault, or the alarm stays for more than a day, call your installer

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
714Fault
BMS Communication Fault

BMS Communication Fault

What you can do

  • Check the app - the battery may show as offline or with no state of charge
  • Restart the system once using the shutdown and start-up steps in your owner's manual (battery last off, first on, unless your manual says otherwise)
  • If the alarm comes back, call your installer - battery communication cables must be checked by them

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
716Fault
Abnormal Battery Connection

Abnormal Battery Connection

What you can do

  • Check the battery status and any extra alarms in the app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If the alarm comes back, or the battery is hot, swollen, noisy or smells, keep clear and call your installer

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
932–935, 937, 939–Fault
Battery Alarm

Battery Alarm

What you can do

  • Check the battery status and any extra alarms in the app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If the alarm comes back, or the battery is hot, swollen, noisy or smells, keep clear and call your installer

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
943, 964, 840Fault
See manual

943, 964, 840

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
703, 707, 708, 711, 712, 715, 717, 732– 737, 739– 747, 832– 837, 839, 841, 844, 864, 866– 868, 870, 1000, 1001Fault
Battery Fault

Battery Fault

What you can do

  • Check the battery status and any extra alarms in the app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If the alarm comes back, or the battery is hot, swollen, noisy or smells, keep clear and call your installer

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
7, 11, 16, 19–25, 30–34, 36, 38, 40–42, 44–50, 52–58, 60–69, 85, 87, 92, 93, 100–105, 107–114, 116–124, 200–211, 248–255, 300–322, 324–328, 401–412, 600–603, 605, 608, 612, 616, 620, 622– 624, 800, 802, 804, 807,Fault
System Fault

System Fault

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
59, 70–74, 76–83, 89, 216–218, 220–233, 432–434, 500–513, 515–518, 635–638, 900, 901, 910, 911,Fault
System Alarm

System Alarm

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
264-283Fault
MPPT Reverse Connection

MPPT Reverse Connection

What you can do

  • Do not touch the DC isolators, cables or connectors
  • Call your installer - this points to a wiring problem that needs a licensed electrician

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
332-363Warning
Boost Capacitor Overvoltage Alarm

Boost Capacitor Overvoltage Alarm

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
364-395Warning
Boost Capacitor Overvoltage Fault

Boost Capacitor Overvoltage Fault

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
1548-1579Fault
String Current Reflux

String Current Reflux

What you can do

  • Check solar generation in the app compared with similar days
  • Do not touch the DC isolators, cables or connectors, and don't go on the roof
  • If it doesn't clear by itself, call your installer

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
1600 - 1615, 1632 -Safety-Critical
PV Grounding Fault

PV Grounding Fault

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter
1616Fault
System Hardware Fault

System Hardware Fault

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid · Guide only. All work must be done by a licensed electrician.

SH3.0-6.0RS / SH5.0-6.0RS-20 single-phase hybrid Inverter

Common Sungrow questions

What does Sungrow 28, 29, 208, 212, 448-479 "PV Reverse Connection Fault" mean?

PV Reverse Connection Fault Do not touch the DC isolators, cables or connectors This is a guide only; any electrical work must be done by a licensed electrician.

What does Sungrow 532-547, 564-579 "PV Reverse Connection Alarm" mean?

PV Reverse Connection Alarm Do not touch the DC isolators, cables or connectors This is a guide only; any electrical work must be done by a licensed electrician.

What does Sungrow 548-563, 580-595 "PV Abnormal Alarm" mean?

PV Abnormal Alarm Check solar generation in the app compared with similar days This is a guide only; any electrical work must be done by a licensed electrician.

What does Sungrow 714 "BMS Communication Fault" mean?

BMS Communication Fault Check the app - the battery may show as offline or with no state of charge This is a guide only; any electrical work must be done by a licensed electrician.

What does Sungrow 716 "Abnormal Battery Connection" mean?

Abnormal Battery Connection Check the battery status and any extra alarms in the app This is a guide only; any electrical work must be done by a licensed electrician.

Need help with this fault?

Get a licensed electrician to call you back.

Total Solar can help: our licensed electricians install and service systems. Based in Ellenbrook, WA, with Victoria and Queensland also available.