Victron error codes explained

What 23 Victron inverter fault and error codes mean, in plain English, with safe checks you can do and when to call a licensed electrician.

Guide only. This information is a general guide taken from manufacturer documentation. All electrical work must be performed by a licensed electrician. Never open your inverter, battery or switchboard. If you see smoke, smell burning or see damage, keep clear and call 000.
CodeMessage & meaningModelType
VE.Bus Error 1Fault
Device is switched off because one of the other phases in the system has switched off

Device is switched off because one of the other phases in the system has switched off

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 2Fault
New and old type MK2 protocol mixed in the system

New and old type MK2 protocol mixed in the system

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 3Fault
Not all, or more than, the expected devices were found in the system

Not all, or more than, the expected devices were found in the system

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 4Fault
No other device found

No other device found

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 5Warning
Overvoltage on AC out

Overvoltage on AC out

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 6Fault
Error in DDC Program

Error in DDC Program

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 7Fault
External device connected, assistant required

External device connected, assistant required

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 8Safety-Critical
Ground relay test failed

Ground relay test failed

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 10Fault
System time synchronisation problem

System time synchronisation problem

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 11Fault
Relay Test Fault - Installation error or possibly relay failure

Relay Test Fault - Installation error or possibly relay failure

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 12Warning
Config mismatch with 2nd mcu

Config mismatch with 2nd mcu

What you can do

  • Make sure the system is online so it can receive updates
  • Restart the system once using the owner steps in your manual
  • If the alarm stays, call your installer - settings and firmware must be fixed by them or the manufacturer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 14Fault
Device cannot transmit data

Device cannot transmit data

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 15Fault
VE

VE.Bus combination error

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 16Warning
VE

VE.Bus dongle is missing

What you can do

  • Check that your home Wi-Fi/internet is working and restart your router
  • Wait an hour - monitoring often reconnects by itself
  • If the inverter screen also shows a fault, or the alarm stays for more than a day, call your installer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 17Fault
Phase master missing

Phase master missing

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 18Warning
AC Over-voltage on the output of a slave while switched off

AC Over-voltage on the output of a slave while switched off

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 19Fault
Slave does not have AC input!

Slave does not have AC input!

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 20Warning
Configuration mismatch

Configuration mismatch

What you can do

  • Make sure the system is online so it can receive updates
  • Restart the system once using the owner steps in your manual
  • If the alarm stays, call your installer - settings and firmware must be fixed by them or the manufacturer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 22Fault
This device cannot function as a slave

This device cannot function as a slave

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 24Fault
Switch-over system protection initiated

Switch-over system protection initiated

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 25Fault
Incompatible VE

Incompatible VE.Bus configuration

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 26Fault
Internal error

Internal error

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter
VE.Bus Error 128Fault
Connect prevented by failing relay test

Connect prevented by failing relay test

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

MultiPlus / Quattro (VE.Bus) · Guide only. All work must be done by a licensed electrician.

MultiPlus / Quattro (VE.Bus) Inverter

Common Victron questions

What does Victron VE.Bus Error 1 "Device is switched off because one of the other phases in the system has switched off" mean?

Device is switched off because one of the other phases in the system has switched off Note the code, then restart the system once using the owner shutdown/start-up steps in your manual This is a guide only; any electrical work must be done by a licensed electrician.

What does Victron VE.Bus Error 2 "New and old type MK2 protocol mixed in the system" mean?

New and old type MK2 protocol mixed in the system Note the code, date and time and check the monitoring app This is a guide only; any electrical work must be done by a licensed electrician.

What does Victron VE.Bus Error 3 "Not all, or more than, the expected devices were found in the system" mean?

Not all, or more than, the expected devices were found in the system Note the code, then restart the system once using the owner shutdown/start-up steps in your manual This is a guide only; any electrical work must be done by a licensed electrician.

What does Victron VE.Bus Error 4 "No other device found" mean?

No other device found Note the code, then restart the system once using the owner shutdown/start-up steps in your manual This is a guide only; any electrical work must be done by a licensed electrician.

What does Victron VE.Bus Error 6 "Error in DDC Program" mean?

Error in DDC Program Note the code, date and time and check the monitoring app This is a guide only; any electrical work must be done by a licensed electrician.

Need help with this fault?

Get a licensed electrician to call you back.

Total Solar can help: our licensed electricians install and service systems. Based in Ellenbrook, WA, with Victoria and Queensland also available.

Or call 1300 209 503

By sending this form you agree to Total Solar (THK Group Pty Ltd) contacting you by phone, SMS or email about this request. We use your details only to respond, as set out in our Privacy Policy.

Sources

Meanings are summarised from these manufacturer documents. Check your own model's manual, as codes vary between models and firmware versions.

Victron is a trademark of its owner. Total Solar is not affiliated with the manufacturer unless stated. All fault code guides

Get a quote Call