Zeversolar error codes explained

What 20 Zeversolar inverter fault and error codes mean, in plain English, with safe checks you can do and when to call a licensed electrician.

Guide only. This information is a general guide taken from manufacturer documentation. All electrical work must be performed by a licensed electrician. Never open your inverter, battery or switchboard. If you see smoke, smell burning or see damage, keep clear and call 000.
CodeMessage & meaningModelType
1Warning
SCI Fault

Communication between the master and slave CPU has failed.

What you can do

  • Check that your home Wi-Fi/internet is working and restart your router
  • Wait an hour - monitoring often reconnects by itself
  • If the inverter screen also shows a fault, or the alarm stays for more than a day, call your installer

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter
2Fault
EEPROM R/W Fault

Reading or writing of EEPROM has failed.

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter
3Fault
Rly-Check Fault

Output relay has failed.

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter
4Fault
DC INJ. High

Output DC feed-in exceeds the permitted upper limit.

What you can do

  • Restart the system once using the owner shutdown/start-up steps in your manual
  • If it comes back, call your installer

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter
6Fault
High DC Bus

The voltage of DC bus exceeds the permitted upper limit.

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter
8Fault
AC HCT Fault

Output current is abnormal.

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter
9Safety-Critical
GFCI Fault

Ground fault detection circuit is abnormal.

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter
10Fault
Device Fault

Unknown error.

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter
33Warning
Fac Fault

The grid frequency is outside the permitted range.

What you can do

  • This is caused by the mains frequency moving outside the allowed range, usually briefly
  • The inverter reconnects by itself once the grid is stable
  • If it keeps happening, note the times and call your installer

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter
34Warning
Vac Fault

The grid voltage is outside the permitted range.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter
35Info
No Utility Grid Available

The utility cannot be detected: no utility, grid disconnected, AC cables damaged, fuse broken or island mode.

What you can do

  • Check whether the rest of your house or street has power, and check your network operator's outage map
  • Check the switchboard for a tripped solar/inverter breaker - reset it once only; if it trips again, leave it off and call an electrician
  • Once normal power is back the inverter usually reconnects on its own within a few minutes
  • If the power is normal but the alarm stays, call your installer

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter
36Safety-Critical
Residual current fault

The residual current exceeds the permitted upper limit.

What you can do

  • Keep clear and do not touch the inverter or cabling
  • Note the code, date and time
  • Call a licensed electrician or Total Solar - this alarm means current may be leaking to earth

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter
37Fault
PV Overvoltage

The voltage of the strings exceeds the permitted upper limit.

What you can do

  • Do not touch the DC isolators or cables
  • Note the time - this often shows on cold, very sunny mornings
  • Call your installer - the panel strings may need to be checked against the inverter's limits

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter
38Safety-Critical
ISO Fault

The PV array's insulation resistance to ground is below the permitted value, or the insulation inside the inverter has failed.

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter
40Warning
Over Temp.

The internal temperature exceeds the permitted value.

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter
41Warning
Vac differs for M-S

Master and slave MCU measured different grid voltage.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter
42Warning
Fac differs for M-S

Master and slave MCU measured different grid frequency.

What you can do

  • This is caused by the mains frequency moving outside the allowed range, usually briefly
  • The inverter reconnects by itself once the grid is stable
  • If it keeps happening, note the times and call your installer

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter
43Safety-Critical
Residual current differs for M-S

Master and slave MCU measured different residual current.

What you can do

  • Keep clear and do not touch the inverter or cabling
  • Note the code, date and time
  • Call a licensed electrician or Total Solar - this alarm means current may be leaking to earth

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter
44Fault
DC Inj. differs for M-S

Master and slave MCU measured different DC feed-in.

What you can do

  • Restart the system once using the owner shutdown/start-up steps in your manual
  • If it comes back, call your installer

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter
45Warning
Fac,Vac differs for M-S

Master and slave MCU measured different grid frequency and voltage.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

Zeverlution 1000S-3000S · Guide only. All work must be done by a licensed electrician.

Zeverlution 1000S-3000S Inverter

Common Zeversolar questions

What does Zeversolar 2 "EEPROM R/W Fault" mean?

Reading or writing of EEPROM has failed. Note the code, then restart the system once using the owner shutdown/start-up steps in your manual This is a guide only; any electrical work must be done by a licensed electrician.

What does Zeversolar 3 "Rly-Check Fault" mean?

Output relay has failed. Note the code, then restart the system once using the owner shutdown/start-up steps in your manual This is a guide only; any electrical work must be done by a licensed electrician.

What does Zeversolar 4 "DC INJ. High" mean?

Output DC feed-in exceeds the permitted upper limit. Restart the system once using the owner shutdown/start-up steps in your manual This is a guide only; any electrical work must be done by a licensed electrician.

What does Zeversolar 6 "High DC Bus" mean?

The voltage of DC bus exceeds the permitted upper limit. Note the code, then restart the system once using the owner shutdown/start-up steps in your manual This is a guide only; any electrical work must be done by a licensed electrician.

What does Zeversolar 8 "AC HCT Fault" mean?

Output current is abnormal. Note the code, date and time and check the monitoring app This is a guide only; any electrical work must be done by a licensed electrician.

Need help with this fault?

Get a licensed electrician to call you back.

Total Solar can help: our licensed electricians install and service systems. Based in Ellenbrook, WA, with Victoria and Queensland also available.