FoxESS H1(G2)/AC1(G2) hybrid & AC-coupled (AU) error codes explained
What 47 FoxESS H1(G2)/AC1(G2) hybrid & AC-coupled (AU) inverter & battery fault and error codes mean, in plain English, with safe checks you can do and when to call a licensed electrician.
Safety first: never open the switchboard, remove covers, or pull apart or disconnect the inverter, batteries, isolators or wiring. Only use the switches and buttons described here. Anything else must be done by a licensed electrician. Call 1300 209 503 or book a service request.
| Code | Message & meaning |
|---|---|
| Grid Lost FaultWarning |
Grid is lostThe inverter cannot see a normal mains supply, so it has stopped exporting to the grid (and a hybrid system may switch to backup). What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Grid Volt FaultWarning |
Grid voltage out of rangeThe mains voltage the inverter measured was outside the limits allowed for your network, so it disconnected or reduced output to protect the grid. This is usually a grid condition, not a faulty inverter. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Grid Freq FaultWarning |
Grid frequency out of rangeGrid frequency moved outside the allowed range, so the inverter disconnected or reduced output as the standards require. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| 10min Volt FaultWarning |
10-minute average grid voltage out of rangeThe mains voltage the inverter measured was outside the limits allowed for your network, so it disconnected or reduced output to protect the grid. This is usually a grid condition, not a faulty inverter. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| SW Inv Cur FaultFault |
Output current high (software)The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| DCI FaultFault |
DC component in output current out of limitThe inverter detected too much DC current in its AC output, which the grid standards don't allow, so it disconnected. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| HW Inv Cur FaultFault |
Output current high (hardware)The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| SW Bus Vol FaultFault |
Bus voltage out of range (software)The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Bat Volt FaultFault |
Battery voltage faultThe battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| SW Bat Cur FaultFault |
Battery current high (software)The battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Iso FaultCritical |
Isolation (insulation) failedThe inverter's insulation check failed. FoxESS states this is how the earth fault alarm (IEC 62109-2 cl. 13.9) appears on this model: the screen shows the isolation fault and the red LED lights. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Res Cur FaultCritical |
Residual current highThe inverter measured leakage (residual) current flowing to earth above its safety limit and disconnected. This can indicate damaged insulation somewhere in the system. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Pv Volt FaultFault |
PV voltage out of rangeThe DC voltage coming from the solar panels is higher than the inverter is rated for. Over-voltage can damage the inverter. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| SW Pv Cur FaultFault |
PV input current high (software)The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Temp FaultWarning |
Inverter temperature highThe inverter is running too hot, so it has reduced output or paused to protect itself. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Ground FaultCritical |
Ground connection failedThe inverter detected a problem with the earth (protective earth/PE) or with the neutral-to-earth connection. A sound earth is essential for electrical safety. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Over Load FaultWarning |
Overload in on-grid modeThe backup/EPS (off-grid) output is overloaded or abnormal, so the system has limited or switched off backup power. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Eps Over LoadWarning |
Overload in off-grid (EPS) modeThe backup/EPS (off-grid) output is overloaded or abnormal, so the system has limited or switched off backup power. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Bat Power LowInfo |
Battery power lowThe battery's state of charge or voltage is low, so the system has stopped discharging it to protect the cells. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| HW Bus Vol FaultFault |
Bus voltage out of range (hardware)The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| HW Pv Cur FaultFault |
PV input current high (hardware)The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| HW Bat Cur FaultFault |
Battery current high (hardware)The battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| SCI FaultFault |
Master-manager communication failedThe equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| MDSP SPI FaultFault |
Master-slave communication failedThe equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| MDSP Smpl FaultFault |
Master sample detection circuit failedThe equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Res Cur HW FaultFault |
Residual current detection device failedThe equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Inv EEPROM FaultFault |
Inverter EEPROM faultThe equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| PvCon Dir FaultFault |
PV connection reversedA solar string or the battery appears to be connected with positive and negative swapped. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Bat Relay OpenFault |
Battery relay stays openThe battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Bat Relay Short CircuitFault |
Battery relay stays closedThe battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Bat Buck FaultFault |
Battery buck circuit MOSFET failedThe battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Bat Boost FaultFault |
Battery boost circuit MOSFET failedThe battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Eps Relay FaultFault |
EPS relay failedThe equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| BatCon Dir FaultFault |
Battery connection reversedA solar string or the battery appears to be connected with positive and negative swapped. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Main Relay OpenFault |
Grid relay stays openThe equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| S1 Close FaultFault |
Grid relay S1 stays closedThe equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| S2 Close FaultFault |
Grid relay S2 stays closedThe equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| M1 Close FaultFault |
Grid relay M1 stays closedThe equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| M2 Close FaultFault |
Grid relay M2 stays closedThe equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| GridV Cons FaultFault |
Grid voltage sample mismatch (master/slave)The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| GridF Cons FaultFault |
Grid frequency sample mismatch (master/slave)The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Dci Cons FaultFault |
DCI sample mismatch (master/slave)The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Rc Cons FaultFault |
Residual current sample mismatch (master/slave)The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| RDSP SPI FaultFault |
Master-slave communication failed (RDSP)The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| RDSP Smpl FaultFault |
Slave sample detection circuit failedThe equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| ARM EEPROM FaultFault |
Manager EEPROM faultThe equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
| Meter Lost FaultWarning |
Meter communication interruptedThe inverter isn't getting correct readings from its energy meter or current sensor (CT). This affects export limiting, battery charging and monitoring accuracy. What you can do
H1(G2)/AC1(G2) hybrid & AC-coupled (AU) · Guide only. All work must be done by a licensed electrician. |
No codes match. Try fewer characters, or ask us.
Need help with this fault?
Get a licensed electrician to call you back.