Growatt error codes explained

What 223 Growatt inverter & battery fault and error codes mean, in plain English, with safe checks you can do and when to call a licensed electrician.

Guide only. This information is a general guide taken from manufacturer documentation. All electrical work must be performed by a licensed electrician. Never open your inverter, battery or switchboard. If you see smoke, smell burning or see damage, keep clear and call 000.

Model guides: Growatt MOD TL3-X (three-phase)

CodeMessage & meaningModelType
Warning 401Warning
SP-CT/Meter Communication fault

The inverter isn't getting correct readings from its energy meter or current sensor (CT). This affects export limiting, battery charging and monitoring accuracy.

What you can do

  • Check the app. Generation may still be running normally
  • Don't open the switchboard
  • Call us to check the meter/CT wiring. If your system has an export limit, this needs fixing promptly

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
Warning 203Fault
PV1 or PV2 Circuit short

The inverter suspects a short circuit or reversed polarity on solar input PV1 or PV2.

What you can do

  • Do not touch any DC wiring
  • Call us or a licensed electrician

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
Warning 506Warning
Battery temperature out of specified range for charge or discharge

The battery temperature is outside the range allowed for charging or discharging, so battery use is paused.

What you can do

  • Check the battery area isn't in direct sun or freezing conditions and the vents are clear
  • Wait for the temperature to return to normal
  • If the battery is hot to the touch, smells or is swelling, keep clear and call us (000 if there is smoke or fire)

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
AC V OutrangeWarning
Grid voltage fault

The mains voltage the inverter measured was outside the limits allowed for your network, so it disconnected or reduced output to protect the grid. This is usually a grid condition, not a faulty inverter.

What you can do

  • Wait. The inverter reconnects by itself once voltage is back within limits
  • Note the time of day it happens. If it happens most sunny days, tell us, because it may need a voltage check or a report to your network operator
  • Don't try to change grid protection settings yourself. In Australia they are set to AS/NZS 4777.2 and your network operator's requirements

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
AC F OutrangeWarning
Grid frequency fault

Grid frequency moved outside the allowed range, so the inverter disconnected or reduced output as the standards require.

What you can do

  • Wait for automatic reconnection
  • If it happens often, record the times and contact us

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
PairingTimeOutWarning
SP-CT communication fault (pairing timeout)

The inverter isn't getting correct readings from its energy meter or current sensor (CT). This affects export limiting, battery charging and monitoring accuracy.

What you can do

  • Check the app. Generation may still be running normally
  • Don't open the switchboard
  • Call us to check the meter/CT wiring. If your system has an export limit, this needs fixing promptly

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
CT LN ReversedWarning
SP-CT L and N reversed

The inverter isn't getting correct readings from its energy meter or current sensor (CT). This affects export limiting, battery charging and monitoring accuracy.

What you can do

  • Check the app. Generation may still be running normally
  • Don't open the switchboard
  • Call us to check the meter/CT wiring. If your system has an export limit, this needs fixing promptly

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
BMS COM FaultFault
Battery (BMS) communication fault

The inverter and battery (or parts inside the battery) have stopped talking to each other, so the battery may stop charging or discharging.

What you can do

  • Check the battery's indicator lights and your monitoring app for other alarms
  • Don't unplug or re-plug cables yourself
  • Call us if it does not clear within a few hours

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
Battery reversedFault
Battery terminals reversed

A solar string or the battery appears to be connected with positive and negative swapped.

What you can do

  • Do not touch any DC wiring
  • Call us or a licensed electrician

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
BAT NTC OpenFault
Battery temperature sensor open (lead-acid only)

The battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation.

What you can do

  • Do not open the battery or touch its terminals
  • Note the exact alarm text and time from the app
  • Call us. Battery faults should be handled by the installer or manufacturer

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
Battery OpenFault
Battery terminal open (lithium)

The inverter and battery (or parts inside the battery) have stopped talking to each other, so the battery may stop charging or discharging.

What you can do

  • Check the battery's indicator lights and your monitoring app for other alarms
  • Don't unplug or re-plug cables yourself
  • Call us if it does not clear within a few hours

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
Over LoadWarning
EPS output overload

The EPS/backup output is overloaded. Growatt notes that after three overloads the off-grid function locks out for an hour before trying again.

What you can do

  • Switch off large appliances on backup circuits
  • Wait for the system to retry (some models lock out for a period after repeated overloads)
  • If it trips with only small loads on, or you suspect a short circuit, call an electrician

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
No AC ConnectionWarning
No utility

The inverter cannot see a normal mains supply, so it has stopped exporting to the grid (and a hybrid system may switch to backup).

What you can do

  • Check whether the rest of the house (or your neighbours) has power, and check your network operator's outage map
  • Check the switchboard for a tripped solar supply main switch or inverter breaker. Only reset it once. If it trips again, leave it off and call an electrician
  • Wait. Once normal grid power is back, the inverter normally reconnects by itself after its safety checks (often a few minutes)
  • If grid power is normal but the alarm stays, call us

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
Output High DCIFault
Output DC current too high

The inverter detected too much DC current in its AC output, which the grid standards don't allow, so it disconnected.

What you can do

  • If it happened once and the system recovered, keep an eye on it
  • If it repeats, call us

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
Bat Voltage HighFault
Battery voltage higher than 60V

The battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation.

What you can do

  • Do not open the battery or touch its terminals
  • Note the exact alarm text and time from the app
  • Call us. Battery faults should be handled by the installer or manufacturer

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
Bat Voltage LowInfo
Battery voltage lower than 42V

The battery's state of charge or voltage is low, so the system has stopped discharging it to protect the cells.

What you can do

  • Allow it to recharge from solar (or the grid, if your settings allow)
  • Check the app for other alarms that could be stopping charging
  • If it stays low for days in good sun, call us. Batteries left flat for long periods can be damaged

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
BMS Warning:XXXFault
BMS reports a warning

The battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation.

What you can do

  • Do not open the battery or touch its terminals
  • Note the exact alarm text and time from the app
  • Call us. Battery faults should be handled by the installer or manufacturer

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
BMS error:XXXFault
BMS reports an error

The battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation.

What you can do

  • Do not open the battery or touch its terminals
  • Note the exact alarm text and time from the app
  • Call us. Battery faults should be handled by the installer or manufacturer

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
EPS Volt LowWarning
EPS output voltage low

The backup/EPS (off-grid) output is overloaded or abnormal, so the system has limited or switched off backup power.

What you can do

  • Switch off large appliances on backup circuits
  • Wait for the system to retry (some models lock out for a period after repeated overloads)
  • If it trips with only small loads on, or you suspect a short circuit, call an electrician

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
Error 411Fault
Internal communication failed

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
Error 417Fault
Sample fault

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
Error 418Fault
DSP and COM firmware version unmatch

There is a firmware, model or configuration mismatch between parts of the system, so it can't run normally.

What you can do

  • Don't try to reflash firmware yourself unless the manufacturer's app tells you to and it's an owner function
  • Call us. We can arrange a firmware update or reconfiguration with the manufacturer

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
Error 303Critical
Inverter L N reversed or ground failed (NE abnormal)

The inverter has found active and neutral reversed, or a missing or poor earth. Growatt's manual says this code is also how an earth fault alarm shows on this model.

What you can do

  • Do not touch the inverter, frames or cabling
  • Leave the system off if it has shut down. Call a licensed electrician or us to test the earthing

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
Error 405Fault
Relay fault

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
Error 123Fault
Autotest failed (Italy only)

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
PV Isolation LowCritical
PV isolation too low

The inverter measured low insulation resistance between the solar/battery DC circuits and earth. In Australia this is treated as an earth fault alarm, and the system must be checked by a licensed electrician.

What you can do

  • Do not touch panels, DC cables, rooftop isolators or the inverter's DC connectors
  • If it clears by itself after the weather dries out, still report it, because repeated alarms point to a developing fault
  • Book an electrician or call us. An insulation test needs specialist equipment
  • If you see smoke, burn marks or smell burning, keep clear and call 000

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
OP Short Fault!Warning
EPS output short fault

The backup/EPS (off-grid) output is overloaded or abnormal, so the system has limited or switched off backup power.

What you can do

  • Switch off large appliances on backup circuits
  • Wait for the system to retry (some models lock out for a period after repeated overloads)
  • If it trips with only small loads on, or you suspect a short circuit, call an electrician

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
NTC OpenFault
Internal temperature sensor failed

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
Error 406Fault
Model set-up does not meet certification

There is a firmware, model or configuration mismatch between parts of the system, so it can't run normally.

What you can do

  • Don't try to reflash firmware yourself unless the manufacturer's app tells you to and it's an owner function
  • Call us. We can arrange a firmware update or reconfiguration with the manufacturer

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
Residual I HighCritical
Leakage current too high

The inverter measured leakage (residual) current flowing to earth above its safety limit and disconnected. This can indicate damaged insulation somewhere in the system.

What you can do

  • Don't touch cabling or equipment
  • If it happens repeatedly, or together with an insulation/isolation alarm, call an electrician or us promptly

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
Error 408Warning
Temperature over range

The inverter is running too hot, so it has reduced output or paused to protect itself.

What you can do

  • Make sure nothing is stacked against or in front of the inverter, and leave the manufacturer's clearances around it
  • Gently clear dust or leaves from the outside of the vents, without opening the unit or spraying water
  • Let it cool. It normally resumes by itself
  • If it keeps happening on mild days, call us

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
PV Voltage HighFault
PV voltage higher than datasheet

The DC voltage coming from the solar panels is higher than the inverter is rated for. Over-voltage can damage the inverter.

What you can do

  • Do not touch the DC isolator or cables unless the manufacturer's owner shutdown tells you to
  • Call us. The string design needs to be checked by a licensed installer

SPH 3000-6000TL BL-UP hybrid · Guide only. All work must be done by a licensed electrician.

SPH 3000-6000TL BL-UP hybrid Inverter
Error 201Critical
Residual I High (leakage current too high)

The inverter measured leakage (residual) current flowing to earth above its safety limit and disconnected. This can indicate damaged insulation somewhere in the system.

What you can do

  • Don't touch cabling or equipment
  • If it happens repeatedly, or together with an insulation/isolation alarm, call an electrician or us promptly

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Error 202Fault
PV Voltage High

The DC voltage coming from the solar panels is higher than the inverter is rated for. Over-voltage can damage the inverter.

What you can do

  • Do not touch the DC isolator or cables unless the manufacturer's owner shutdown tells you to
  • Call us. The string design needs to be checked by a licensed installer

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Error 203Critical
PV Isolation Low

The inverter measured low insulation resistance between the solar/battery DC circuits and earth. In Australia this is treated as an earth fault alarm, and the system must be checked by a licensed electrician.

What you can do

  • Do not touch panels, DC cables, rooftop isolators or the inverter's DC connectors
  • If it clears by itself after the weather dries out, still report it, because repeated alarms point to a developing fault
  • Book an electrician or call us. An insulation test needs specialist equipment
  • If you see smoke, burn marks or smell burning, keep clear and call 000

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Error 300Warning
AC V Outrange

The mains voltage the inverter measured was outside the limits allowed for your network, so it disconnected or reduced output to protect the grid. This is usually a grid condition, not a faulty inverter.

What you can do

  • Wait. The inverter reconnects by itself once voltage is back within limits
  • Note the time of day it happens. If it happens most sunny days, tell us, because it may need a voltage check or a report to your network operator
  • Don't try to change grid protection settings yourself. In Australia they are set to AS/NZS 4777.2 and your network operator's requirements

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Error 302Warning
No AC connection

The inverter cannot see a normal mains supply, so it has stopped exporting to the grid (and a hybrid system may switch to backup).

What you can do

  • Check whether the rest of the house (or your neighbours) has power, and check your network operator's outage map
  • Check the switchboard for a tripped solar supply main switch or inverter breaker. Only reset it once. If it trips again, leave it off and call an electrician
  • Wait. Once normal grid power is back, the inverter normally reconnects by itself after its safety checks (often a few minutes)
  • If grid power is normal but the alarm stays, call us

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Error 303Critical
PE abnormal (N-PE voltage above 30V)

The inverter detected a problem with the earth (protective earth/PE) or with the neutral-to-earth connection. A sound earth is essential for electrical safety.

What you can do

  • Do not touch the inverter, frames or cabling
  • Leave the system off if it has shut down. Call a licensed electrician or us to test the earthing

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Error 304Warning
AC F Outrange

Grid frequency moved outside the allowed range, so the inverter disconnected or reduced output as the standards require.

What you can do

  • Wait for automatic reconnection
  • If it happens often, record the times and contact us

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Error 407Fault
Auto Test Failed

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Warning 202Fault
DC SPD function abnormal

A surge protection device (SPD) inside or connected to the inverter is reporting a fault, often after a lightning storm or grid surge.

What you can do

  • Don't open the inverter
  • Call us. SPDs must be replaced by a licensed electrician

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Warning 203Fault
PV1 or PV2 Circuit short

Growatt's manual describes this as a short circuit on solar input PV1 or PV2 and suggests checking panel polarity, which is a job for an electrician.

What you can do

  • Do not touch any DC wiring
  • Call us or a licensed electrician

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Warning 204Info
Dry contact function abnormal

The system has received a shutdown or control signal, or a protective input has been triggered (for example an emergency stop, demand response or external switch).

What you can do

  • Check whether anyone operated an emergency stop or shutdown switch on purpose
  • If so, follow the manual to release it only when it is safe
  • If nobody did, call us

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Warning 205Fault
PV1 or PV2 boost broken

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Warning 207Info
USB over-current

A monitoring or communication accessory (Wi-Fi/4G/data logger, display or clock) is reporting a problem. This usually doesn't stop the system generating.

What you can do

  • Restart your home router and check it reaches the inverter location
  • If you changed router or Wi-Fi password, the dongle needs reconfiguring (see the manufacturer's app guide or ask us)
  • If generation looks normal but the alarm persists, call us

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Warning 401Warning
Inverter communicates with Meter abnormal

The inverter isn't getting correct readings from its energy meter or current sensor (CT). This affects export limiting, battery charging and monitoring accuracy.

What you can do

  • Check the app. Generation may still be running normally
  • Don't open the switchboard
  • Call us to check the meter/CT wiring. If your system has an export limit, this needs fixing promptly

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Warning 404Fault
EEPROM abnormal

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Warning 405Fault
Firmware version is not consistent

There is a firmware, model or configuration mismatch between parts of the system, so it can't run normally.

What you can do

  • Don't try to reflash firmware yourself unless the manufacturer's app tells you to and it's an owner function
  • Call us. We can arrange a firmware update or reconfiguration with the manufacturer

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Error 402Fault
Output High DCI

The inverter detected too much DC current in its AC output, which the grid standards don't allow, so it disconnected.

What you can do

  • If it happened once and the system recovered, keep an eye on it
  • If it repeats, call us

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Error 404Fault
Bus sample fault

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Error 405Fault
Relay fault

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Error 408Warning
Over Temperature

The inverter is running too hot, so it has reduced output or paused to protect itself.

What you can do

  • Make sure nothing is stacked against or in front of the inverter, and leave the manufacturer's clearances around it
  • Gently clear dust or leaves from the outside of the vents, without opening the unit or spraying water
  • Let it cool. It normally resumes by itself
  • If it keeps happening on mild days, call us

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Error 409Fault
Bus over voltage

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Error 411Fault
DSP communicates with M3 abnormal

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Error 414Fault
EEPROM fault

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Error 417Fault
DSP and redundant M3 sampled data differ

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Error 420Fault
GFCI fault

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Error 200Critical
AFCI fault (listed in MIC TL-X manual)

The inverter's arc-fault detection has picked up a pattern that looks like electrical arcing on the DC (solar) side, which can be a fire risk. The inverter shuts down DC power flow as a precaution.

What you can do

  • Do not reset it repeatedly and do not touch DC cables or isolators
  • If you see smoke or flames or smell burning, keep clear and call 000
  • Call us or a licensed electrician to inspect the DC wiring before the system is restarted

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Error 425Fault
AFCI self-test fault (listed in MIC TL-X manual)

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) · Guide only. All work must be done by a licensed electrician.

MIN TL-X / MIN TL-XH / MIC TL-X (single-phase) Inverter
Warning 200Warning
String fault

One solar string is behaving differently from the others (lower output or current flowing the wrong way), which often points to a panel, connector or configuration issue.

What you can do

  • From the ground, check for new shading (trees, new structures) or obvious debris
  • Compare string readings in your monitoring app if available
  • Book a service check if it continues

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 201Fault
String PID quick-connect terminal detection error

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 202Fault
DC SPD function abnormal

A surge protection device (SPD) inside or connected to the inverter is reporting a fault, often after a lightning storm or grid surge.

What you can do

  • Don't open the inverter
  • Call us. SPDs must be replaced by a licensed electrician

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 203Fault
PV circuit short

A solar string or the battery appears to be connected with positive and negative swapped.

What you can do

  • Do not touch any DC wiring
  • Call us or a licensed electrician

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 204Info
Dry contact function abnormal

The system has received a shutdown or control signal, or a protective input has been triggered (for example an emergency stop, demand response or external switch).

What you can do

  • Check whether anyone operated an emergency stop or shutdown switch on purpose
  • If so, follow the manual to release it only when it is safe
  • If nobody did, call us

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 205Fault
PV boost driver broken

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 206Fault
AC SPD function abnormal

A surge protection device (SPD) inside or connected to the inverter is reporting a fault, often after a lightning storm or grid surge.

What you can do

  • Don't open the inverter
  • Call us. SPDs must be replaced by a licensed electrician

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 207Info
USB (U disk) over-current protection

A monitoring or communication accessory (Wi-Fi/4G/data logger, display or clock) is reporting a problem. This usually doesn't stop the system generating.

What you can do

  • Restart your home router and check it reaches the inverter location
  • If you changed router or Wi-Fi password, the dongle needs reconfiguring (see the manufacturer's app guide or ask us)
  • If generation looks normal but the alarm persists, call us

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 208Fault
DC fuse open

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 209Fault
DC input voltage exceeds maximum

The DC voltage coming from the solar panels is higher than the inverter is rated for. Over-voltage can damage the inverter.

What you can do

  • Do not touch the DC isolator or cables unless the manufacturer's owner shutdown tells you to
  • Call us. The string design needs to be checked by a licensed installer

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 210Fault
PV reversed

A solar string or the battery appears to be connected with positive and negative swapped.

What you can do

  • Do not touch any DC wiring
  • Call us or a licensed electrician

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 300Warning
No utility

The inverter cannot see a normal mains supply, so it has stopped exporting to the grid (and a hybrid system may switch to backup).

What you can do

  • Check whether the rest of the house (or your neighbours) has power, and check your network operator's outage map
  • Check the switchboard for a tripped solar supply main switch or inverter breaker. Only reset it once. If it trips again, leave it off and call an electrician
  • Wait. Once normal grid power is back, the inverter normally reconnects by itself after its safety checks (often a few minutes)
  • If grid power is normal but the alarm stays, call us

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 301Warning
Grid voltage out of range

The mains voltage the inverter measured was outside the limits allowed for your network, so it disconnected or reduced output to protect the grid. This is usually a grid condition, not a faulty inverter.

What you can do

  • Wait. The inverter reconnects by itself once voltage is back within limits
  • Note the time of day it happens. If it happens most sunny days, tell us, because it may need a voltage check or a report to your network operator
  • Don't try to change grid protection settings yourself. In Australia they are set to AS/NZS 4777.2 and your network operator's requirements

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 302Warning
Grid frequency out of range

Grid frequency moved outside the allowed range, so the inverter disconnected or reduced output as the standards require.

What you can do

  • Wait for automatic reconnection
  • If it happens often, record the times and contact us

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 303Warning
EPS mode overload

The backup/EPS (off-grid) output is overloaded or abnormal, so the system has limited or switched off backup power.

What you can do

  • Switch off large appliances on backup circuits
  • Wait for the system to retry (some models lock out for a period after repeated overloads)
  • If it trips with only small loads on, or you suspect a short circuit, call an electrician

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 304Warning
CT open or wrong

The inverter isn't getting correct readings from its energy meter or current sensor (CT). This affects export limiting, battery charging and monitoring accuracy.

What you can do

  • Check the app. Generation may still be running normally
  • Don't open the switchboard
  • Call us to check the meter/CT wiring. If your system has an export limit, this needs fixing promptly

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 305Warning
CT line reversed or ground fail

The inverter isn't getting correct readings from its energy meter or current sensor (CT). This affects export limiting, battery charging and monitoring accuracy.

What you can do

  • Check the app. Generation may still be running normally
  • Don't open the switchboard
  • Call us to check the meter/CT wiring. If your system has an export limit, this needs fixing promptly

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 306Warning
Communication fault: M3 didn't receive SP-CT data

The inverter isn't getting correct readings from its energy meter or current sensor (CT). This affects export limiting, battery charging and monitoring accuracy.

What you can do

  • Check the app. Generation may still be running normally
  • Don't open the switchboard
  • Call us to check the meter/CT wiring. If your system has an export limit, this needs fixing promptly

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 307Fault
Communication fault

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 400Warning
Fan function abnormal

A cooling fan isn't working properly, which can make the unit run hot and reduce output.

What you can do

  • From outside, check that nothing is blocking the vents
  • Don't open the unit
  • Call us to arrange a fan check or replacement

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 401Warning
Meter abnormal

The inverter isn't getting correct readings from its energy meter or current sensor (CT). This affects export limiting, battery charging and monitoring accuracy.

What you can do

  • Check the app. Generation may still be running normally
  • Don't open the switchboard
  • Call us to check the meter/CT wiring. If your system has an export limit, this needs fixing promptly

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 402Fault
Optimiser and inverter communication abnormal

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 403Fault
String communication abnormal

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 404Fault
EEPROM abnormal

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 405Fault
DSP and COM firmware version unmatch

There is a firmware, model or configuration mismatch between parts of the system, so it can't run normally.

What you can do

  • Don't try to reflash firmware yourself unless the manufacturer's app tells you to and it's an owner function
  • Call us. We can arrange a firmware update or reconfiguration with the manufacturer

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warning 406Fault
Boost module error

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 200Critical
AFCI fault

The inverter's arc-fault detection has picked up a pattern that looks like electrical arcing on the DC (solar) side, which can be a fire risk. The inverter shuts down DC power flow as a precaution.

What you can do

  • Do not reset it repeatedly and do not touch DC cables or isolators
  • If you see smoke or flames or smell burning, keep clear and call 000
  • Call us or a licensed electrician to inspect the DC wiring before the system is restarted

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 201Critical
Leakage current too high

The inverter measured leakage (residual) current flowing to earth above its safety limit and disconnected. This can indicate damaged insulation somewhere in the system.

What you can do

  • Don't touch cabling or equipment
  • If it happens repeatedly, or together with an insulation/isolation alarm, call an electrician or us promptly

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 202Fault
DC input voltage exceeds maximum

The DC voltage coming from the solar panels is higher than the inverter is rated for. Over-voltage can damage the inverter.

What you can do

  • Do not touch the DC isolator or cables unless the manufacturer's owner shutdown tells you to
  • Call us. The string design needs to be checked by a licensed installer

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 203Critical
PV isolation low

The inverter measured low insulation resistance between the solar/battery DC circuits and earth. In Australia this is treated as an earth fault alarm, and the system must be checked by a licensed electrician.

What you can do

  • Do not touch panels, DC cables, rooftop isolators or the inverter's DC connectors
  • If it clears by itself after the weather dries out, still report it, because repeated alarms point to a developing fault
  • Book an electrician or call us. An insulation test needs specialist equipment
  • If you see smoke, burn marks or smell burning, keep clear and call 000

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 300Warning
AC V Outrange

The mains voltage the inverter measured was outside the limits allowed for your network, so it disconnected or reduced output to protect the grid. This is usually a grid condition, not a faulty inverter.

What you can do

  • Wait. The inverter reconnects by itself once voltage is back within limits
  • Note the time of day it happens. If it happens most sunny days, tell us, because it may need a voltage check or a report to your network operator
  • Don't try to change grid protection settings yourself. In Australia they are set to AS/NZS 4777.2 and your network operator's requirements

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 301Fault
AC terminals reversed

The inverter has detected an AC wiring problem, for example active and neutral swapped or a connection made the wrong way round.

What you can do

  • Do not touch any wiring
  • Leave the system as it is and book a licensed electrician (or call us)

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 302Warning
No AC connection

The inverter cannot see a normal mains supply, so it has stopped exporting to the grid (and a hybrid system may switch to backup).

What you can do

  • Check whether the rest of the house (or your neighbours) has power, and check your network operator's outage map
  • Check the switchboard for a tripped solar supply main switch or inverter breaker. Only reset it once. If it trips again, leave it off and call an electrician
  • Wait. Once normal grid power is back, the inverter normally reconnects by itself after its safety checks (often a few minutes)
  • If grid power is normal but the alarm stays, call us

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 303Critical
NE abnormal

The inverter detected a problem with the earth (protective earth/PE) or with the neutral-to-earth connection. A sound earth is essential for electrical safety.

What you can do

  • Do not touch the inverter, frames or cabling
  • Leave the system off if it has shut down. Call a licensed electrician or us to test the earthing

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 304Warning
AC F Outrange

Grid frequency moved outside the allowed range, so the inverter disconnected or reduced output as the standards require.

What you can do

  • Wait for automatic reconnection
  • If it happens often, record the times and contact us

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 305Warning
Overload fault

The backup/EPS (off-grid) output is overloaded or abnormal, so the system has limited or switched off backup power.

What you can do

  • Switch off large appliances on backup circuits
  • Wait for the system to retry (some models lock out for a period after repeated overloads)
  • If it trips with only small loads on, or you suspect a short circuit, call an electrician

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 306Warning
CT LN reversed

The inverter isn't getting correct readings from its energy meter or current sensor (CT). This affects export limiting, battery charging and monitoring accuracy.

What you can do

  • Check the app. Generation may still be running normally
  • Don't open the switchboard
  • Call us to check the meter/CT wiring. If your system has an export limit, this needs fixing promptly

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 307Warning
Communication fault: M3 didn't receive SP-CT data

The inverter isn't getting correct readings from its energy meter or current sensor (CT). This affects export limiting, battery charging and monitoring accuracy.

What you can do

  • Check the app. Generation may still be running normally
  • Don't open the switchboard
  • Call us to check the meter/CT wiring. If your system has an export limit, this needs fixing promptly

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 308Warning
Communication fault: pairing time too long

The inverter isn't getting correct readings from its energy meter or current sensor (CT). This affects export limiting, battery charging and monitoring accuracy.

What you can do

  • Check the app. Generation may still be running normally
  • Don't open the switchboard
  • Call us to check the meter/CT wiring. If your system has an export limit, this needs fixing promptly

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 400Fault
DCI bias abnormal

The inverter detected too much DC current in its AC output, which the grid standards don't allow, so it disconnected.

What you can do

  • If it happened once and the system recovered, keep an eye on it
  • If it repeats, call us

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 401Fault
DC voltage high fault

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 402Fault
Output DC current too high

The inverter detected too much DC current in its AC output, which the grid standards don't allow, so it disconnected.

What you can do

  • If it happened once and the system recovered, keep an eye on it
  • If it repeats, call us

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 403Fault
Output current unbalance

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 404Fault
Bus sample fault

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 405Fault
Relay fault

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 406Fault
Init model fault

There is a firmware, model or configuration mismatch between parts of the system, so it can't run normally.

What you can do

  • Don't try to reflash firmware yourself unless the manufacturer's app tells you to and it's an owner function
  • Call us. We can arrange a firmware update or reconfiguration with the manufacturer

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 407Fault
Auto test failure

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 408Warning
NTC temperature too high

The inverter is running too hot, so it has reduced output or paused to protect itself.

What you can do

  • Make sure nothing is stacked against or in front of the inverter, and leave the manufacturer's clearances around it
  • Gently clear dust or leaves from the outside of the vents, without opening the unit or spraying water
  • Let it cool. It normally resumes by itself
  • If it keeps happening on mild days, call us

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 409Fault
Bus voltage abnormal

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 410Fault
Communication board / control panel battery-voltage sampling inconsistent

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 411Fault
Communication fault

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 412Fault
Temperature sensor connection abnormal

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 413Fault
IGBT drive fault

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 414Fault
EEPROM fault

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 415Fault
Internal power test fail (PV power low)

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 416Fault
Overcurrent protected by software

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 417Fault
Grid voltage sampling inconsistent

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 418Fault
DSP and COM firmware version unmatch

There is a firmware, model or configuration mismatch between parts of the system, so it can't run normally.

What you can do

  • Don't try to reflash firmware yourself unless the manufacturer's app tells you to and it's an owner function
  • Call us. We can arrange a firmware update or reconfiguration with the manufacturer

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 419Fault
Inconsistent leakage current sampling

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 420Fault
GFCI module damage

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 421Fault
CPLD abnormal

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 422Fault
Sampling inconsistent

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Error 425Fault
AFCI self-test fault

The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.

What you can do

  • Note the code, time and whether it clears by itself
  • If your installer showed you the owner shutdown/restart procedure from the manufacturer's manual (summarised at the top of this page), you may restart the system once. Do not open covers or touch cabling.
  • If the code returns or the system stays offline, call us. Internal faults are a warranty/technician job

MOD TL3-X (three-phase) · Guide only. All work must be done by a licensed electrician.

MOD TL3-X (three-phase) Inverter
Warn 304Warning
CT Open (MIN 7000-10000TL-X with cable CT)

On MIN 7-10k TL-X inverters that use a cable CT for export limiting, the inverter isn't getting a valid CT signal. Growatt says this warning was removed in DSP firmware AMAA04xx and later, and recommends a smart meter instead of a cable CT.

What you can do

  • Check the app. Generation may still be running normally
  • Don't open the switchboard
  • Call us to check the meter/CT wiring. If your system has an export limit, this needs fixing promptly

Growatt Australia Helpdesk articles (MIC/MIN/MOD/SPH with smart meter) · Guide only. All work must be done by a licensed electrician.

Growatt Australia Helpdesk articles (MIC/MIN/MOD/SPH with smart meter) Inverter
Warn 308Warning
Meter Open

The readings coming from the smart meter aren't changing, which usually means the CT clamp isn't on the right cable or the meter link has a problem.

What you can do

  • Check the app. Generation may still be running normally
  • Don't open the switchboard
  • Call us to check the meter/CT wiring. If your system has an export limit, this needs fixing promptly

Growatt Australia Helpdesk articles (MIC/MIN/MOD/SPH with smart meter) · Guide only. All work must be done by a licensed electrician.

Growatt Australia Helpdesk articles (MIC/MIN/MOD/SPH with smart meter) Inverter
Warn 309Warning
Meter Reverse

The meter reports more export than the inverter is producing. Typical causes are a CT clamp or meter wiring the wrong way round, or another inverter on site.

What you can do

  • Check the app. Generation may still be running normally
  • Don't open the switchboard
  • Call us to check the meter/CT wiring. If your system has an export limit, this needs fixing promptly

Growatt Australia Helpdesk articles (MIC/MIN/MOD/SPH with smart meter) · Guide only. All work must be done by a licensed electrician.

Growatt Australia Helpdesk articles (MIC/MIN/MOD/SPH with smart meter) Inverter
Warn 401Warning
Meter communication (no data from meter)

Export limiting or power sensing is switched on, but the inverter receives no data from the smart meter.

What you can do

  • Check the app. Generation may still be running normally
  • Don't open the switchboard
  • Call us to check the meter/CT wiring. If your system has an export limit, this needs fixing promptly

Growatt Australia Helpdesk articles (MIC/MIN/MOD/SPH with smart meter) · Guide only. All work must be done by a licensed electrician.

Growatt Australia Helpdesk articles (MIC/MIN/MOD/SPH with smart meter) Inverter
Error 69 (at start-up)Info
Start-up error 69 after a shutdown

Growatt Australia says that when an SPM restarts some time after a normal shutdown, it may briefly show start-up error 69, which normally clears by itself after about 10 minutes.

What you can do

  • Wait about 10 minutes for it to clear
  • If it does not clear, call us

SPM 8000-10000TL-HU hybrid (Helpdesk troubleshooting guide) · Guide only. All work must be done by a licensed electrician.

SPM 8000-10000TL-HU hybrid (Helpdesk troubleshooting guide) Inverter
Error 90 (at start-up)Info
Start-up error 90 after a shutdown

Growatt Australia says that when an SPM restarts some time after a normal shutdown, it may briefly show start-up error 90, which normally clears by itself after about 10 minutes.

What you can do

  • Wait about 10 minutes for it to clear
  • If it does not clear, call us

SPM 8000-10000TL-HU hybrid (Helpdesk troubleshooting guide) · Guide only. All work must be done by a licensed electrician.

SPM 8000-10000TL-HU hybrid (Helpdesk troubleshooting guide) Inverter
Meter1CommFailWarning
Meter1CommFail

Meter1 communication fault

What you can do

  • Check the monitoring app for the alarm and whether export/consumption readings look wrong
  • Restart your home router if the meter talks over Wi-Fi or LAN
  • Call your installer - meter and CT wiring is inside the switchboard and must be checked by a licensed electrician

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
BattChrOrDisFailFault
BattChrOrDisFail

The battery cannot charge or discharge normally

What you can do

  • Check the battery status and any extra alarms in the app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If the alarm comes back, or the battery is hot, swollen, noisy or smells, keep clear and call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
M1AbnormalWireWarning
M1AbnormalWire

Meter1 wiring error

What you can do

  • Check the monitoring app for the alarm and whether export/consumption readings look wrong
  • Restart your home router if the meter talks over Wi-Fi or LAN
  • Call your installer - meter and CT wiring is inside the switchboard and must be checked by a licensed electrician

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Meter2CommFailWarning
Meter2CommFail

Meter2 communication fault

What you can do

  • Check the monitoring app for the alarm and whether export/consumption readings look wrong
  • Restart your home router if the meter talks over Wi-Fi or LAN
  • Call your installer - meter and CT wiring is inside the switchboard and must be checked by a licensed electrician

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Warning401Warning
Meter Communication fault

Meter Communication fault

What you can do

  • Check the monitoring app for the alarm and whether export/consumption readings look wrong
  • Restart your home router if the meter talks over Wi-Fi or LAN
  • Call your installer - meter and CT wiring is inside the switchboard and must be checked by a licensed electrician

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Warning506Safety-Critical
Battery temperature out of specified range for charge or discharge

Battery temperature out of specified range for charge or discharge

What you can do

  • Check from a safe distance for heat, swelling, hissing, a burning smell or smoke - if you notice any, keep everyone away and call 000
  • If nothing looks wrong, make sure the battery area is shaded and ventilated and nothing is stacked against it
  • Let the battery cool; most units recover by themselves
  • If the alarm keeps returning, call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
AC V OutrangeWarning
AC V Outrange

Grid voltage fault. Please refer to the local grid standard for more details about the grid voltage.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
AC F OutrangeWarning
AC F Outrange

Grid frequency fault. Please refer to the local grid standard for more details about the grid frequency.

What you can do

  • This is caused by the mains frequency moving outside the allowed range, usually briefly
  • The inverter reconnects by itself once the grid is stable
  • If it keeps happening, note the times and call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
BMS COM FaultFault
BMS COM Fault

Communication fault

What you can do

  • Check the app - the battery may show as offline or with no state of charge
  • Restart the system once using the shutdown and start-up steps in your owner's manual (battery last off, first on, unless your manual says otherwise)
  • If the alarm comes back, call your installer - battery communication cables must be checked by them

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Battery reversedFault
Battery reversed

Battery terminals reversed

What you can do

  • Check the battery status and any extra alarms in the app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If the alarm comes back, or the battery is hot, swollen, noisy or smells, keep clear and call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Over loadWarning
Over load

EPS output overload warning. If this warning occurred three times, the off-grid function will be locked for one hour.

What you can do

  • Turn off some large appliances (air-conditioners, ovens, kettles, pool pumps) - backup outputs have a power limit
  • The system usually recovers by itself once the load drops
  • If it keeps happening with normal loads, call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
No AC ConnectionInfo
No AC Connection

No Utility

What you can do

  • Check whether the rest of your house or street has power, and check your network operator's outage map
  • Check the switchboard for a tripped solar/inverter breaker - reset it once only; if it trips again, leave it off and call an electrician
  • Once normal power is back the inverter usually reconnects on its own within a few minutes
  • If the power is normal but the alarm stays, call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Output High DCIFault
Output High DCI

High DC component in the output power. Please refer to the local grid standard for disconnection time when the output DC current is too high.

What you can do

  • Restart the system once using the owner shutdown/start-up steps in your manual
  • If it comes back, call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Bat Voltage HighFault
Bat Voltage High

Battery Voltage higher than 560V

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Bat Voltage LowInfo
Bat Voltage Low

Battery Voltage lower than 100 V

What you can do

  • This normally means the battery is low or has reached its reserve level
  • Let the system recharge from solar or the grid - check the state of charge in the app
  • If the battery never charges or stays at 0% for more than a day of sunshine, call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
BMS Warning:XXXFault
BMS Warning:XXX

BMS report warning

What you can do

  • Check the battery status and any extra alarms in the app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If the alarm comes back, or the battery is hot, swollen, noisy or smells, keep clear and call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
BMS error:XXXFault
BMS error:XXX

BMS report error

What you can do

  • Check the battery status and any extra alarms in the app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If the alarm comes back, or the battery is hot, swollen, noisy or smells, keep clear and call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
EPS Volt LowWarning
EPS Volt Low

EPS output voltage low

What you can do

  • Turn off some large appliances (air-conditioners, ovens, kettles, pool pumps) - backup outputs have a power limit
  • The system usually recovers by itself once the load drops
  • If it keeps happening with normal loads, call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Inverter fault codeFault
Inverter fault code

LCD Display

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Error 300Warning
AC V Outrange (1)

AC V Outrange (1)

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Error 304Fault
AC F Outrange

AC F Outrange

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Error 302Info
No AC Connection

No AC Connection

What you can do

  • Check whether the rest of your house or street has power, and check your network operator's outage map
  • Check the switchboard for a tripped solar/inverter breaker - reset it once only; if it trips again, leave it off and call an electrician
  • Once normal power is back the inverter usually reconnects on its own within a few minutes
  • If the power is normal but the alarm stays, call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Error 604Warning
EPS Volt Low

EPS Volt Low

What you can do

  • Turn off some large appliances (air-conditioners, ovens, kettles, pool pumps) - backup outputs have a power limit
  • The system usually recovers by itself once the load drops
  • If it keeps happening with normal loads, call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Error 607Warning
EPS Over Load

EPS Over Load

What you can do

  • Turn off some large appliances (air-conditioners, ovens, kettles, pool pumps) - backup outputs have a power limit
  • The system usually recovers by itself once the load drops
  • If it keeps happening with normal loads, call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Error 505Fault
Battery reversed

Battery reversed

What you can do

  • Check the battery status and any extra alarms in the app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If the alarm comes back, or the battery is hot, swollen, noisy or smells, keep clear and call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Error 506Fault
Battery Open

Battery Open

What you can do

  • Check the battery status and any extra alarms in the app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If the alarm comes back, or the battery is hot, swollen, noisy or smells, keep clear and call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Error 502Fault
Bat Voltage Low

Bat Voltage Low

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Error 503Fault
Bat Voltage High

Bat Voltage High

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Error 500Fault
BMS COM Fault

BMS COM Fault

What you can do

  • Check the battery status and any extra alarms in the app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If the alarm comes back, or the battery is hot, swollen, noisy or smells, keep clear and call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Error 402Fault
Output High DCI

Output High DCI

What you can do

  • Restart the system once using the owner shutdown/start-up steps in your manual
  • If it comes back, call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Error 203Safety-Critical
PV Isolation Low

PV Isolation Low

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Error 202Fault
PV Voltage High

PV Voltage High

What you can do

  • Do not touch the DC isolators or cables
  • Note the time - this often shows on cold, very sunny mornings
  • Call your installer - the panel strings may need to be checked against the inverter's limits

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Error 600Fault
OP Short Fault

OP Short Fault

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Pv1 shortFault
Pv1 short

Pv1 short

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Pv2 shortFault
Pv2 short

Pv2 short

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
CT LN ReversedWarning
CT LN Reversed

CT LN Reversed

What you can do

  • Check the monitoring app for the alarm and whether export/consumption readings look wrong
  • Restart your home router if the meter talks over Wi-Fi or LAN
  • Call your installer - meter and CT wiring is inside the switchboard and must be checked by a licensed electrician

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Error 507Warning
Over Load

Over Load

What you can do

  • Turn off some large appliances (air-conditioners, ovens, kettles, pool pumps) - backup outputs have a power limit
  • The system usually recovers by itself once the load drops
  • If it keeps happening with normal loads, call your installer

SPH 4000-10000TL3 BH-UP three-phase hybrid · Guide only. All work must be done by a licensed electrician.

SPH 4000-10000TL3 BH-UP three-phase hybrid Inverter
Warning 203Fault
PV1 or PV2 Circuit short

PV1 or PV2 Circuit short

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
Warning 204Fault
Dryconnect function abnormal

Dryconnect function abnormal

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
Warning 205Fault
Pv1 or PV2 boost broken

Pv1 or PV2 boost broken

What you can do

  • Check solar generation in the app compared with similar days
  • Do not touch the DC isolators, cables or connectors, and don't go on the roof
  • If it doesn't clear by itself, call your installer

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
Warning 207Fault
USB over-current

USB over-current

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
Warning 401Warning
Inverter communicates with Meter abnormal

Inverter communicates with Meter abnormal

What you can do

  • Check the monitoring app for the alarm and whether export/consumption readings look wrong
  • Restart your home router if the meter talks over Wi-Fi or LAN
  • Call your installer - meter and CT wiring is inside the switchboard and must be checked by a licensed electrician

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
Warning 404Fault
EEPROM abnormal

EEPROM abnormal

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
Warning 405Warning
Firmware version is not consistent

Firmware version is not consistent

What you can do

  • Make sure the system is online so it can receive updates
  • Restart the system once using the owner steps in your manual
  • If the alarm stays, call your installer - settings and firmware must be fixed by them or the manufacturer

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
Residual I High Error: 201Safety-Critical
Residual I High Error: 201

Leakage current too high

What you can do

  • Keep clear and do not touch the inverter or cabling
  • Note the code, date and time
  • Call a licensed electrician or Total Solar - this alarm means current may be leaking to earth

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
PV Voltage High Error: 202Fault
PV Voltage High Error: 202

The DC input voltage is exceeding the maximum tolerable value.

What you can do

  • Do not touch the DC isolators or cables
  • Note the time - this often shows on cold, very sunny mornings
  • Call your installer - the panel strings may need to be checked against the inverter's limits

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
PV Isolation Low Error: 203Safety-Critical
PV Isolation Low Error: 203

Insulation problem

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
AC V Outrange Error: 300Warning
AC V Outrange Error: 300

Utility grid voltage is out of permissible range.

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
No AC connection Error: 302Info
No AC connection Error: 302

No AC connection

What you can do

  • Check whether the rest of your house or street has power, and check your network operator's outage map
  • Check the switchboard for a tripped solar/inverter breaker - reset it once only; if it trips again, leave it off and call an electrician
  • Once normal power is back the inverter usually reconnects on its own within a few minutes
  • If the power is normal but the alarm stays, call your installer

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
PE abnormal Error: 303Safety-Critical
PE abnormal Error: 303

Voltage of Neutral and PE above 30V.

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
AC F Outrange Error: 304Warning
AC F Outrange Error: 304

Utility grid frequency out of permissible range.

What you can do

  • This is caused by the mains frequency moving outside the allowed range, usually briefly
  • The inverter reconnects by itself once the grid is stable
  • If it keeps happening, note the times and call your installer

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
Auto Test Failed Error: 407Fault
Auto Test Failed Error: 407

Auto test didn't pass.

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
Error: 402Fault
Output High DCI

Output High DCI

What you can do

  • Restart the system once using the owner shutdown/start-up steps in your manual
  • If it comes back, call your installer

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
Error: 404Fault
Bus sample fault

Bus sample fault

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
Error: 405Fault
Relay fault

Relay fault

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
Error: 408Warning
Over Temperature

Over Temperature

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
Error: 409Fault
Bus over voltage

Bus over voltage

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
Error: 411Warning
DSP communicates with M3 abnormal

DSP communicates with M3 abnormal

What you can do

  • Check that your home Wi-Fi/internet is working and restart your router
  • Wait an hour - monitoring often reconnects by itself
  • If the inverter screen also shows a fault, or the alarm stays for more than a day, call your installer

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
Error: 414Fault
EEPROM fault

EEPROM fault

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
Error: 417Fault
The data sampled by the DSP and redundant M3 is not the same

The data sampled by the DSP and redundant M3 is not the same

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
Error: 420Safety-Critical
GFCI fault

GFCI fault

What you can do

  • Keep clear and do not touch the inverter or cabling
  • Note the code, date and time
  • Call a licensed electrician or Total Solar - this alarm means current may be leaking to earth

MIN 2500-6000TL-XH hybrid-ready · Guide only. All work must be done by a licensed electrician.

MIN 2500-6000TL-XH hybrid-ready Inverter
( ALM Light Flickers)Info
( ALM Light Flickers)

Discharge under voltage protection

What you can do

  • This normally means the battery is low or has reached its reserve level
  • Let the system recharge from solar or the grid - check the state of charge in the app
  • If the battery never charges or stays at 0% for more than a day of sunshine, call your installer

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Charge over voltage protectionFault
Charge over voltage protection

Single cell voltage exceeding threshold for protection threshold.

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
External RS485 Communication failureWarning
External RS485 Communication failure

Communication loss between hybrid inverter and battery system.

What you can do

  • Check that your home Wi-Fi/internet is working and restart your router
  • Wait an hour - monitoring often reconnects by itself
  • If the inverter screen also shows a fault, or the alarm stays for more than a day, call your installer

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
ProtectionFault
Protection

Cell charge overvoltage alarm

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Cell charge overvoltage protectionFault
Cell charge overvoltage protection

(t=1S)

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Charge total voltage overvoltage alarmFault
Charge total voltage overvoltage alarm

(t=1S)

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Charge total voltage overvoltage protectionFault
Charge total voltage overvoltage protection

(t=1S)

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Charge and discharge over current alarmFault
Charge and discharge over current alarm

(t=1S)

What you can do

  • Turn off any very large loads that were running when the alarm appeared
  • Wait - many over-current protections reset automatically
  • If it keeps happening, call your installer

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Charge and discharge high temperatur e alarmWarning
Charge and discharge high temperatur e alarm

(t=1S)

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Charge and discharge low temperatur e alarmInfo
Charge and discharge low temperatur e alarm

(t=1S)

What you can do

  • This normally means the battery is low or has reached its reserve level
  • Let the system recharge from solar or the grid - check the state of charge in the app
  • If the battery never charges or stays at 0% for more than a day of sunshine, call your installer

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Cell discharge Under- voltage alarmInfo
Cell discharge Under- voltage alarm

(t=1S)

What you can do

  • This normally means the battery is low or has reached its reserve level
  • Let the system recharge from solar or the grid - check the state of charge in the app
  • If the battery never charges or stays at 0% for more than a day of sunshine, call your installer

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Cell discharge under voltage protectionInfo
Cell discharge under voltage protection

(t=1S)

What you can do

  • This normally means the battery is low or has reached its reserve level
  • Let the system recharge from solar or the grid - check the state of charge in the app
  • If the battery never charges or stays at 0% for more than a day of sunshine, call your installer

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Discharge total voltage under voltage alarmInfo
Discharge total voltage under voltage alarm

(t=1S)

What you can do

  • This normally means the battery is low or has reached its reserve level
  • Let the system recharge from solar or the grid - check the state of charge in the app
  • If the battery never charges or stays at 0% for more than a day of sunshine, call your installer

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Ambient temperatur e over- temperatur e alarmWarning
Ambient temperatur e over- temperatur e alarm

(t=1S)

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Cell voltage difference is too large alarmFault
Cell voltage difference is too large alarm

(t=1S)

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Cell rapid over voltage protectionFault
Cell rapid over voltage protection

(t=1S)

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Battery pack over voltage alarmWarning
Battery pack over voltage alarm

(t=1S)

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Battery pack over voltage protectionWarning
Battery pack over voltage protection

(t=1S)

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Battery pack under voltage alarmWarning
Battery pack under voltage alarm

(t=1S)

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Battery pack under voltage protectionWarning
Battery pack under voltage protection

(t=1S)

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Precharged overtime circuitFault
Precharged overtime circuit

(t=1S)

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Interior CAN communicat ion failureFault
Interior CAN communicat ion failure

(t=1S)

What you can do

  • Check the app - the battery may show as offline or with no state of charge
  • Restart the system once using the shutdown and start-up steps in your owner's manual (battery last off, first on, unless your manual says otherwise)
  • If the alarm comes back, call your installer - battery communication cables must be checked by them

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Insulation fault alarmSafety-Critical
Insulation fault alarm

(t=1S)

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
UART communicat ion timeout alarmWarning
UART communicat ion timeout alarm

(t=1S)

What you can do

  • Check that your home Wi-Fi/internet is working and restart your router
  • Wait an hour - monitoring often reconnects by itself
  • If the inverter screen also shows a fault, or the alarm stays for more than a day, call your installer

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Abnormal output port voltageFault
Abnormal output port voltage

(t=1S)

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Cell failure protectionFault
Cell failure protection

(t=1S)

What you can do

  • Check the battery status and any extra alarms in the app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If the alarm comes back, or the battery is hot, swollen, noisy or smells, keep clear and call your installer

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Main circuit failure protectionFault
Main circuit failure protection

(t=1S)

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
EEPROM fault protectionFault
EEPROM fault protection

(t=1S)

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Front-end chip failure protectionFault
Front-end chip failure protection

(t=1S)

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
EEPROM calibration parameter failureWarning
EEPROM calibration parameter failure

(t=1S)

What you can do

  • Check the monitoring app for the alarm and whether export/consumption readings look wrong
  • Restart your home router if the meter talks over Wi-Fi or LAN
  • Call your installer - meter and CT wiring is inside the switchboard and must be checked by a licensed electrician

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Total voltage sampling failureFault
Total voltage sampling failure

(t=1S)

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
The motherboar d power supply is abnormalFault
The motherboar d power supply is abnormal

(t=1S)

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Insulation resistance protectionSafety-Critical
Insulation resistance protection

(t=1S)

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery
Hardware reference voltage abnormal failureFault
Hardware reference voltage abnormal failure

(t=1S)

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

ARK 5.12-25.6H-A1 (ARK XH) battery · Guide only. All work must be done by a licensed electrician.

ARK 5.12-25.6H-A1 (ARK XH) battery Battery

Common Growatt questions

What does Growatt Warning 203 "PV1 or PV2 Circuit short" mean?

The inverter suspects a short circuit or reversed polarity on solar input PV1 or PV2. Do not touch any DC wiring This is a guide only; any electrical work must be done by a licensed electrician.

What does Growatt BMS COM Fault "Battery (BMS) communication fault" mean?

The inverter and battery (or parts inside the battery) have stopped talking to each other, so the battery may stop charging or discharging. Check the battery's indicator lights and your monitoring app for other alarms This is a guide only; any electrical work must be done by a licensed electrician.

What does Growatt Battery reversed "Battery terminals reversed" mean?

A solar string or the battery appears to be connected with positive and negative swapped. Do not touch any DC wiring This is a guide only; any electrical work must be done by a licensed electrician.

What does Growatt BAT NTC Open "Battery temperature sensor open (lead-acid only)" mean?

The battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation. Do not open the battery or touch its terminals This is a guide only; any electrical work must be done by a licensed electrician.

What does Growatt Battery Open "Battery terminal open (lithium)" mean?

The inverter and battery (or parts inside the battery) have stopped talking to each other, so the battery may stop charging or discharging. Check the battery's indicator lights and your monitoring app for other alarms This is a guide only; any electrical work must be done by a licensed electrician.

Need help with this fault?

Get a licensed electrician to call you back.

Total Solar can help: our licensed electricians install and service systems. Based in Ellenbrook, WA, with Victoria and Queensland also available.