Sigenergy error codes explained
What 147 Sigenergy inverter & battery fault and error codes mean, in plain English, with safe checks you can do and when to call a licensed electrician.
Safety first: never open the switchboard, remove covers, or pull apart or disconnect the inverter, batteries, isolators or wiring. Only use the switches and buttons described here. Anything else must be done by a licensed electrician. Call 1300 209 503 or book a service request.
Model guides: Sigenergy SigenStor / Sigen Hybrid / Gateway / battery
| Code | Message & meaning |
|---|---|
| 1001Fault |
The software version does not matchThere is a firmware, model or configuration mismatch between parts of the system, so it can't run normally. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1002Critical |
Low insulation resistanceThe inverter measured low insulation resistance between the solar/battery DC circuits and earth. In Australia this is treated as an earth fault alarm, and the system must be checked by a licensed electrician. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1003Warning |
Over-temperatureThe inverter is running too hot, so it has reduced output or paused to protect itself. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1004Fault |
Equipment faultThe equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1005Critical |
System grounding faultThe inverter detected a problem with the earth (protective earth/PE) or with the neutral-to-earth connection. A sound earth is essential for electrical safety. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1006Fault |
PV string overvoltageThe DC voltage coming from the solar panels is higher than the inverter is rated for. Over-voltage can damage the inverter. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1007Fault |
PV string reversely connectedA solar string or the battery appears to be connected with positive and negative swapped. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1008Warning |
PV string sinking currentOne solar string is behaving differently from the others (lower output or current flowing the wrong way), which often points to a panel, connector or configuration issue. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1009Critical |
AFCI faultThe inverter's arc-fault detection has picked up a pattern that looks like electrical arcing on the DC (solar) side, which can be a fire risk. The inverter shuts down DC power flow as a precaution. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1010Warning |
Grid power outageThe inverter cannot see a normal mains supply, so it has stopped exporting to the grid (and a hybrid system may switch to backup). What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1011Warning |
Grid overvoltageThe mains voltage the inverter measured was outside the limits allowed for your network, so it disconnected or reduced output to protect the grid. This is usually a grid condition, not a faulty inverter. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1012Warning |
Grid undervoltageThe mains voltage the inverter measured was outside the limits allowed for your network, so it disconnected or reduced output to protect the grid. This is usually a grid condition, not a faulty inverter. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1013Warning |
Grid overfrequencyGrid frequency moved outside the allowed range, so the inverter disconnected or reduced output as the standards require. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1014Warning |
Grid underfrequencyGrid frequency moved outside the allowed range, so the inverter disconnected or reduced output as the standards require. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1015Warning |
Grid voltage imbalanceThe inverter saw something abnormal about the grid supply (for example phase loss, imbalance, waveform distortion or loss of mains), so it disconnected as a safety measure. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1016Fault |
DC component of output current out of limitThe inverter detected too much DC current in its AC output, which the grid standards don't allow, so it disconnected. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1017Critical |
Leak current out of limitThe inverter measured leakage (residual) current flowing to earth above its safety limit and disconnected. This can indicate damaged insulation somewhere in the system. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1018Warning |
Communication faultA communication link has dropped. The sub-ID tells you which one: ID1 4G, ID2 internal CAN, ID3 energy meter, ID4 Gateway. A 4G (ID1) alarm is usually just data or signal, while ID2–ID4 point to wiring or connector problems. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1019Fault |
Internal protectionThe equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1020Fault |
Abnormal AFCI self-checking circuitThe equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1021Warning |
Inverter AC side voltage abnormalThe backup/EPS (off-grid) output is overloaded or abnormal, so the system has limited or switched off backup power. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1022Info |
Manual operation protectionAn emergency power-off (EPO) or emergency shutdown signal has been triggered, so the system has stopped on purpose. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1024Warning |
Abnormal phase sequenceThe inverter saw something abnormal about the grid supply (for example phase loss, imbalance, waveform distortion or loss of mains), so it disconnected as a safety measure. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1025Critical |
Short circuit to PEThe inverter detected a problem with the earth (protective earth/PE) or with the neutral-to-earth connection. A sound earth is essential for electrical safety. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1026Fault |
Soft start failureThe equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 1027Warning |
Grid frequency unstableGrid frequency moved outside the allowed range, so the inverter disconnected or reduced output as the standards require. What you can do
SigenStor / Sigen Hybrid inverter (PV & grid side) · Guide only. All work must be done by a licensed electrician. |
| 2001Fault |
The software version does not matchThere is a firmware, model or configuration mismatch between parts of the system, so it can't run normally. What you can do
SigenStor battery & energy-storage (DC) module · Guide only. All work must be done by a licensed electrician. |
| 2002Critical |
The energy storage module has low insulation resistance to the groundThe inverter measured low insulation resistance between the solar/battery DC circuits and earth. In Australia this is treated as an earth fault alarm, and the system must be checked by a licensed electrician. What you can do
SigenStor battery & energy-storage (DC) module · Guide only. All work must be done by a licensed electrician. |
| 2003Critical |
Over-temperatureThe battery module or its power module inside the SigenStor is too hot (sub-ID1 power module, ID2 battery module), so operation is limited or stopped. What you can do
SigenStor battery & energy-storage (DC) module · Guide only. All work must be done by a licensed electrician. |
| 2004Fault |
Equipment faultThe battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation. What you can do
SigenStor battery & energy-storage (DC) module · Guide only. All work must be done by a licensed electrician. |
| 2005Warning |
Under-temperatureThe battery is too cold to charge or discharge safely, so it is pausing until it warms up. What you can do
SigenStor battery & energy-storage (DC) module · Guide only. All work must be done by a licensed electrician. |
| 2006Fault |
Battery module over-voltageThe battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation. What you can do
SigenStor battery & energy-storage (DC) module · Guide only. All work must be done by a licensed electrician. |
| 2007Fault |
Battery module undervoltageThe battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation. What you can do
SigenStor battery & energy-storage (DC) module · Guide only. All work must be done by a licensed electrician. |
| 2008Fault |
Internal protectionThe battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation. What you can do
SigenStor battery & energy-storage (DC) module · Guide only. All work must be done by a licensed electrician. |
| 3001Fault |
The software version does not matchThere is a firmware, model or configuration mismatch between parts of the system, so it can't run normally. What you can do
Sigen Gateway (backup/grid switching) · Guide only. All work must be done by a licensed electrician. |
| 3002Warning |
Over-temperatureThe inverter is running too hot, so it has reduced output or paused to protect itself. What you can do
Sigen Gateway (backup/grid switching) · Guide only. All work must be done by a licensed electrician. |
| 3003Fault |
Equipment faultThe equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. What you can do
Sigen Gateway (backup/grid switching) · Guide only. All work must be done by a licensed electrician. |
| 3004Critical |
Too high off-grid output leak currentThe inverter measured leakage (residual) current flowing to earth above its safety limit and disconnected. This can indicate damaged insulation somewhere in the system. What you can do
Sigen Gateway (backup/grid switching) · Guide only. All work must be done by a licensed electrician. |
| 3005Critical |
Neutral point grounding faultThe inverter detected a problem with the earth (protective earth/PE) or with the neutral-to-earth connection. A sound earth is essential for electrical safety. What you can do
Sigen Gateway (backup/grid switching) · Guide only. All work must be done by a licensed electrician. |
| 3006Fault |
Abnormal Phase Se- quence Of Power Grid WiringThe inverter has detected an AC wiring problem, for example active and neutral swapped or a connection made the wrong way round. What you can do
Sigen Gateway (backup/grid switching) · Guide only. All work must be done by a licensed electrician. |
| 3007Fault |
Load Side Wiring Phase Sequence AbnormalThe inverter has detected an AC wiring problem, for example active and neutral swapped or a connection made the wrong way round. What you can do
Sigen Gateway (backup/grid switching) · Guide only. All work must be done by a licensed electrician. |
| 3008Warning |
Grid phase lossThe inverter saw something abnormal about the grid supply (for example phase loss, imbalance, waveform distortion or loss of mains), so it disconnected as a safety measure. What you can do
Sigen Gateway (backup/grid switching) · Guide only. All work must be done by a licensed electrician. |
| 3009Warning |
Grid failureThe mains voltage the inverter measured was outside the limits allowed for your network, so it disconnected or reduced output to protect the grid. This is usually a grid condition, not a faulty inverter. What you can do
Sigen Gateway (backup/grid switching) · Guide only. All work must be done by a licensed electrician. |
| 3010Warning |
Generator failureA problem was detected with a connected generator input (voltage, frequency, wiring or start-up). What you can do
Sigen Gateway (backup/grid switching) · Guide only. All work must be done by a licensed electrician. |
| 3011Warning |
Load faultThe backup/EPS (off-grid) output is overloaded or abnormal, so the system has limited or switched off backup power. What you can do
Sigen Gateway (backup/grid switching) · Guide only. All work must be done by a licensed electrician. |
| 3012Warning |
Abnormal phase sequence of engine connectionA problem was detected with a connected generator input (voltage, frequency, wiring or start-up). What you can do
Sigen Gateway (backup/grid switching) · Guide only. All work must be done by a licensed electrician. |
| 3013Info |
Emergency shutdownAn emergency power-off (EPO) or emergency shutdown signal has been triggered, so the system has stopped on purpose. What you can do
Sigen Gateway (backup/grid switching) · Guide only. All work must be done by a licensed electrician. |
| 3014Warning |
Bypass Switch OpenThe Gateway's bypass switch is reported open/abnormal. What you can do
Sigen Gateway (backup/grid switching) · Guide only. All work must be done by a licensed electrician. |
| 3015Warning |
Bypass Switch OnThe Gateway's bypass switch is reported switched on (system bypassed). What you can do
Sigen Gateway (backup/grid switching) · Guide only. All work must be done by a licensed electrician. |
| 4001Warning |
Communication faultThe inverter isn't getting correct readings from its energy meter or current sensor (CT). This affects export limiting, battery charging and monitoring accuracy. What you can do
System / communication · Guide only. All work must be done by a licensed electrician. |
| 4003Warning |
Diesel generator startup failureA problem was detected with a connected generator input (voltage, frequency, wiring or start-up). What you can do
System / communication · Guide only. All work must be done by a licensed electrician. |
| 4004Warning |
CLS faultSigenergy lists a "CLS malfunction" and says it can be cleared manually in the app. The manual doesn't explain the term further. What you can do
System / communication · Guide only. All work must be done by a licensed electrician. |
| 1001Warning |
The software version does not matchThe inverter software version does not match The equipment's internal software version does not match If the upgrade is unsuccessful, please submit fault feedback on the APP-service-troubleshooting page. What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1002Safety-Critical |
Low insulation resistanceLow insulation resistance The PV string is short circuited to the PE, or the PV string is installed in a chronically humid env 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1003Warning |
Over-temperatureInverter over-temperature Too high ambient temperature, poor ventilation in the installation location Malfunction of the int Generally, the machine will be restarted after the internal temperature or module temperature returns to nor- mal, if the failure occurs repeatedly: 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1004Fault |
Equipment faultMalfunction of the power module Internal circuit fault 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1005Safety-Critical |
System grounding faultSystem grounding fault PE cable not grounded 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1006Fault |
PV string overvoltageString 1 input overvoltage Too many strings in series What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1007Fault |
PV string reversely con- nectedString 1 reversely connected Positive and negative terminals reversely con- nected 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1008Fault |
PV string sinking currentString 1 sinking current Inconsistent configuration of strings 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1009Safety-Critical |
AFCI faultAFCI fault of string 1 DC cable damaged Poor contact of string con- nector 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1010Info |
Grid power outageGrid power outage Grid power outage or AC switch turned off Under normal circumstances, the inverter will be reconnected to the grid after the grid returns to normal What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1011Warning |
Grid overvoltageGrid overvoltage Level I The grid voltage is greater than the overvoltage threshold Level I Under normal circumstances, the inverter will be reconnected to the grid after the grid returns to normal What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1012Warning |
Grid undervoltageGrid undervoltage Level I The grid voltage is less than the undervoltage threshold I Under normal circumstances, the inverter will be reconnected to the grid after the grid returns to normal What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1013Warning |
Grid overfrequencyGrid overfrequency Level I The grid frequency is greater than the overfre- quency threshold Level I Under normal circumstances, the inverter will be reconnected to the grid after the grid returns to normal What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1014Warning |
Grid underfrequencyGrid underfrequency Level I The grid frequency is less than the underfrequen- cy threshold Level I Under normal circumstances, the inverter will be reconnected to the grid after the grid returns to normal What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1015Warning |
Grid voltage imbalanceGrid voltage imbalance Three-phase grid phase angle imbalance Three- phase grid amplitude imbalance Under normal circumstances, the inverter will be reconnected to the grid after the grid returns to normal What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1016Fault |
DC component of output current out of limitDC component of output current out of limit The DC component in the AC output current is greater than the set point 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1017Safety-Critical |
Leak current out of limitLeak current out of limit The leak current exceeds the protection threshold This may be occasionally caused by transient environmental changes What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1018Warning |
Communication fault4G communication fault Insufficient 4G traffic or SIM card not inserted Poor contact of internal communication Dongle Please check the 4G data, if the data is insufficient, please recharge What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1019Fault |
Internal protectionMPPT1 overcurrent protection MPPT overcurrent protection triggered This may be occasionally caused by transient environmental changes What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1020Safety-Critical |
Abnormal AFCI self-check- ing circuitAFCI self-checking circuit 1 fault DC arc detection circuit self-checking failed 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1021Warning |
Inverter AC side voltage abnormalAC side overload protection AC side voltage below threshold 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1022Fault |
Manual operation protec- tionEPO protection The customer presses the rapid shutdown button in emergency What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1023Fault |
Neutral line abnormality in inverterNeutral wire disconnected in the inverter The neutral line in the inverter is not connected or is loose 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1024Warning |
Abnormal phase sequenceAbnormal phase sequence of three-phase grid Abnormal phase sequence of three-phase grid Adjust the sequence of the three-phase wiring on the AC output side What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1025Safety-Critical |
Short circuit to PEThree-phase grid is short circuited to the PE Three-phase grid is short circuited to the PE Check if there is a phase-to-ground short circuit on the grid side wiring What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1026Fault |
Soft start failureSoft start failure Soft start failure If it occurs accidentally, it may be caused by a transient change in the environment What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1028Fault |
Built-in GATEWAY device failureGrid port relay open circuit fault Internal circuit failure in the equipment 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1029Fault |
Built-in GATEWAY wiring abnormalAbnormal grid connection phase sequence Abnormal grid connection 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1030Warning |
Built-in GATEWAY load failurePhase A load overvoltage Low phase A voltage of the load 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 1031Fault |
Built-in GATEWAY port overcurrentOvercurrent at grid-side phase A port Excessive current flows through the A-phase port on the grid side 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2001Warning |
The software version does not matchSoftware version mismatch The equipment's internal software version does not match Please upgrade the system software again; If the fault still exists, please submit fault feedback on the APP-service-support-troubleshooting page. What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2002Safety-Critical |
The energy storage module has low insulation resist- ance to the groundEnergy storage module has low insulation impedance to ground The energy storage module is short circuited to the housing 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2003Warning |
Over-temperatureHigh temperature of energy storage power module Too high ambient temperature, poor ventilation in the installation location Malfunction of the in- ternal power module results in abnormal internal heating What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2004Fault |
Equipment faultEnergy storage control circuit abnormal Internal circuit fault 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2005Safety-Critical |
Under-temperatureLow temperature of energy storage battery module Too low ambient temperature 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2006Fault |
Battery module over-volt- ageBattery module overvoltage Too high voltage of the battery module or cells therein What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2007Fault |
Battery module undervolt- ageBattery module undervoltage Too low voltage of the battery module or cells therein What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2008Fault |
Internal protectionOvervoltage protection of the pow- er module Internal overvoltage protection triggered 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2101Warning |
Software Version MismatchSoftware Version Mismatch The internal software version of the all-in-one machine does not match Please upgrade again What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2102Safety-Critical |
Low Insulation Resistance To Ground In Energy Stor- age ClusterLow Insulation Resistance To Ground Of Energy Storage Module Internal Short Circuit To The Enclosure Of The Energy Storage Module 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2103Warning |
Temperature Of The Power Module In The Energy Stor- age Cluster Is Too HighHigh Temperature In Energy Stor- age Power Module The ambient temperature is too high, the equip- ment installation location is not ventilated; the power module inside the equipment is malfunc- tioning 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2104Safety-Critical |
Battery Module Temper- ature In Energy Storage Cluster Too HighEnergy Storage Battery Module Temperature High What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2105Fault |
Equipment FailureEnergy Storage Control Circuit Abnormal Internal Circuit Malfunction 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2106Safety-Critical |
Temperature Too LowEnergy Storage Battery Module Temperature Low Ambient Temperature Is Too Low 1.Wait for the ambient temperature to rise to the operating temperature range of the equipment, and the fault can be automatically resolved What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2107Fault |
Battery Cluster Module OvervoltageBattery Module Overvoltage Battery module or cell voltage within the module is too high; battery module overcharged Please Submit Fault Feedback On The APP-support-troubleshooting Page What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2108Fault |
Battery Cluster Module UndervoltageBattery Module Undervoltage Battery module or cell voltage within the module is too low, long-term storage leads to power loss Please Submit Fault Feedback On The APP-support-troubleshooting Page What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2109Fault |
Internal equipment protec- tionPower module input overvoltage protection Trigger the internal overvoltage protection mech- anism of the device 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2110Fault |
Cluster power limitationBattery cluster module overcurrent power limit The charge and discharge current of the battery module is relatively large 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2111Fault |
Wiring abnormalityAbnormal DC busbar wiring DC busbar positive and negative poles reversed 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2201Warning |
Version mismatchSoftware version mismatch The internal software version of the all-in-one machine does not match Please upgrade again, if the fault still exists, please submit a fault report on the APP-support-troubleshoot- ing page What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2202Safety-Critical |
Battery module tempera- ture too highHigh temperature of energy storage battery module The ambient temperature is too high, and the installation location is not ventilated 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2203Warning |
Equipment failureAuxiliary source anomaly Auxiliary module anomaly: balancing module abnormal; detection module anomaly: generally refers to overcurrent, voltage difference 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2204Safety-Critical |
Temperature too lowThe temperature of the energy storage battery module is low Ambient temperature too low 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2205Fault |
Battery module overvoltageBattery module overvoltage The battery module or the cell voltage within the module is too high Please submit fault feedback on the APP-support-troubleshooting page What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2206Fault |
Battery module undervolt- ageBattery module undervoltage The battery module or the cell voltage within the module is too low Please submit fault feedback on the APP-support-troubleshooting page What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2207Fault |
The power of the battery module is limitedBattery module voltage high limit power The voltage of the battery module or the cells within the module is relatively high 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2301Warning |
Software version mismatchProtocol version mismatch The internal software versions of the device do not match Version mismatch or upgrade unsuccessful, please upgrade again What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2302Warning |
OvertemperatureJunction box temperature is high The ambient temperature is too high, and the installation location of the equipment is not ven- tilated The internal power module of the equipment is malfunctioning, resulting in severe internal heating 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2303Fault |
Equipment failureAC soft start failure Internal circuit failure in the equipment 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 2304Warning |
Wiring abnormalityPower line reverse connection The power cable or network cable is not properly connected 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 3001Warning |
The software version does not matchSoftware and hardware version mismatch Mismatched versions of various subcomponents in the all-in-one system What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 3002Warning |
Over-temperatureTemperature too high High ambient temperature, inadequate ventilation at the equipment installation location; abnormal operation of internal components in the device What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 3003Fault |
Equipment faultAuxiliary power source abnormal Internal circuit failure in the device What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 3004Safety-Critical |
Too high off-grid output leak currentExcessive off-grid output leakage current Off-grid scenario, high leakage current in the load What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 3005Safety-Critical |
Neutral point grounding faultNeutral point grounding fault Off-grid scenario: High voltage between N and PE; LN reversed (European gateway) Check if the functional ground is effectively connected to the external ground What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 3006Fault |
Abnormal Phase Sequence Of Power Grid WiringGrid wiring phase sequence abnor- mality Power Grid Connection Abnormality 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 3007Fault |
Load Side Wiring Phase Sequence AbnormalInverter wiring phase sequence abnormality Load Side Wiring Abnormality 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 3008Warning |
Grid phase lossGrid phase loss For three-phase equipment, if the three-phase grid voltage is not fully connected to the equip- ment, there is a lack of one phase or two phases in the grid voltage What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 3009Info |
Grid failureGrid phase A overvoltaged Grid phase A voltage is too high 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 3010Warning |
Generator failureGenerator phase A overvoltaged Generator phase A voltage is too high 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 3011Warning |
Load faultOvervoltage on Load Phase A High Voltage on Load Phase A 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 3012Fault |
Abnormal phase sequence of engine connectionAbnormal phase sequence of en- gine connection Abnormal Wiring Of Oil Machine 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 3014Fault |
Bypass Switch OpenBypass Switch Abnormal Bypass switch open, cannot close 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 3015Fault |
Bypass Switch OnBypass Switch On Bypass Switch On 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 3016Warning |
Contactor coil overvoltageGrid contactor coil overvoltage Grid contactor coil overvoltage 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 3017Fault |
The cabinet door opensThe cabinet door opens The cabinet door status feedback contact is high resistance 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 3018Fault |
Frame circuit breaker over- current protectionOvercurrent protection for grid-side frame circuit breaker The feedback contact of the grid-side frame cir- cuit breaker fault is low resistance What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 3019Fault |
Frame circuit breaker ex- ceeds service lifeThe mechanical lifespan of the grid framework circuit breaker has been exceeded The mechanical lifespan of the grid framework circuit breaker has been exceeded 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 4001Warning |
Communication faultGateway communication anomaly Poor communication contact between the gate- way and the all-in-one machine 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 4002Warning |
Wiring anomalyPhase A CT reverse connection Phase A CT reverse connection Rewire according to the cause What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 4003Fault |
Diesel generator startup failureEngine start anomaly Engine start anomaly None What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 4004Fault |
CLS faultCLS malfunction CLS malfunction Clearing the fault on the App. What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 4005Fault |
Feed-in power limit hard protectionFeed-in power limit protection When the grid feed-in power limit hard protection is enabled, exceeding the grid feed-in power limit will trigger hard protection What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 4006Safety-Critical |
DI custom faultOVGR fault Ground fault overvoltage relay triggers protection Please check for any system grounding faults What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 5001Warning |
Equipment protectionGrid input overvoltage Actual grid voltage exceeds rated voltage by 20% What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 5002Safety-Critical |
Equipment faultLeakage detection circuit abnormal Leakage detection circuit failure 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 5003Warning |
Over-temperatureInternal temperature too high 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 5004Info |
Charging cable faultCharging cable specification ab- normal For a charger with a socket, the charging cable has abnormal current-carrying capacity What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 5005Warning |
Meter communication faultMeter communication abnormal The meter loses communication with the charger for more than 1 minute What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 5101Warning |
The software version does not matchSoftware version mismatch The equipment's internal software version does not match If the version does not match or the upgrade is unsuccessful, please upgrade again, if the upgrade is unsuc- cessful for multiple times, Please submit a fault report on the support-troubleshooting page of the mySigen app. What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 5102Safety-Critical |
Low insulation resistanceLow insulation resistance The resistance of the positive and negative bus- bars to ground is too small 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 5103Warning |
Over-temperatureInternal temperature too high The ambient temperature is too high, and the equipment is installed in a poorly ventilated loca- tion; The power module inside the equipment is malfunctioning, leading to severe internal heat- ing; The LLC power module is overheating, and the BUCK power module is also overheating What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 5104Warning |
Equipment faultExternal fan malfunction External fan malfunction 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 5105Safety-Critical |
Charging faultControl guidance malfunction CP pin disconnection, CP to ground short circuit 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
| 5106Fault |
Equipment protectionOvervoltage protection LLC overvoltage, BUCK overvoltage 1 What you can do
SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician. |
No codes match. Try fewer characters, or ask us.
Common Sigenergy questions
What does Sigenergy 1001 "The software version does not match" mean?
There is a firmware, model or configuration mismatch between parts of the system, so it can't run normally. Don't try to reflash firmware yourself unless the manufacturer's app tells you to and it's an owner function This is a guide only; any electrical work must be done by a licensed electrician.
What does Sigenergy 1004 "Equipment fault" mean?
The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician. Note the code and sub-ID from the mySigen app This is a guide only; any electrical work must be done by a licensed electrician.
What does Sigenergy 1006 "PV string overvoltage" mean?
The DC voltage coming from the solar panels is higher than the inverter is rated for. Over-voltage can damage the inverter. Do not touch the DC isolator or cables unless the manufacturer's owner shutdown tells you to This is a guide only; any electrical work must be done by a licensed electrician.
What does Sigenergy 1007 "PV string reversely connected" mean?
A solar string or the battery appears to be connected with positive and negative swapped. Do not touch any DC wiring This is a guide only; any electrical work must be done by a licensed electrician.
What does Sigenergy 1016 "DC component of output current out of limit" mean?
The inverter detected too much DC current in its AC output, which the grid standards don't allow, so it disconnected. If it happened once and the system recovered, keep an eye on it This is a guide only; any electrical work must be done by a licensed electrician.
Need help with this fault?
Get a licensed electrician to call you back.