Sigenergy SigenStor alarm codes explained
SigenStor systems show a four-digit alarm code in the mySigen app, often with a sub-ID (for example 1018 ID3) that tells you which string, phase or link is affected. Find your four-digit code below. The sub-ID list is shown inside each entry.
Safety first, please read
- Solar panels and batteries produce dangerous DC voltage whenever there is daylight or charge in the battery, even with the mains switched off. Electrical work on these systems must only be done by a licensed electrician.
- Never open the inverter or battery, and don't unplug, touch or adjust DC cables, connectors or isolators except for the owner shutdown steps in your manufacturer's manual.
- For an isolation/insulation fault, earth fault, arc fault, residual-current fault or battery over-temperature alarm, or any smoke, burning smell, hissing, swelling, leaking or water damage: only switch off if the manufacturer's procedure lets you do it safely, keep everyone clear, and call a licensed electrician or Total Solar.
- If there is fire or smoke, get everyone out and call 000. Tell the fire service there is a solar and battery system on site.
- Don't climb on the roof to check or clean panels. Do checks from the ground only.
Owner shutdown and restart (Sigenergy (SigenStor))
Sigenergy's SigenStor Home User Manual lets owners turn the system off and on from the mySigen app (Settings). There is also an ON/OFF button behind the decorative cover (hold for more than 3 seconds), and an optional emergency power-off (EPO) button. If you power off with the button, you must power on with the button. Use the app method unless your installer has shown you otherwise.
- SigenStor / Sigen Hybrid inverter (PV & grid side)
- SigenStor battery & energy-storage (DC) module
- Sigen Gateway (backup/grid switching)
- System / communication
SigenStor / Sigen Hybrid inverter (PV & grid side) (26 codes)
1001The software version does not matchFault
What it means: There is a firmware, model or configuration mismatch between parts of the system, so it can't run normally.
Sub-IDs: ID1: The inverter software version does not match; ID2: The inverter software & hardware ver- sion does not match; ID3: The protocol versions among equip- ment do not match
Likely causes:
- Interrupted or partial firmware update
- Parts replaced with different firmware versions
- Incorrect model or country/region setting
What you can safely do:
- Don't try to reflash firmware yourself unless the manufacturer's app tells you to and it's an owner function
- Call us. We can arrange a firmware update or reconfiguration with the manufacturer
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1002Low insulation resistanceSafety-critical
What it means: The inverter measured low insulation resistance between the solar/battery DC circuits and earth. In Australia this is treated as an earth fault alarm, and the system must be checked by a licensed electrician.
Likely causes:
- Damaged DC cable insulation (for example from rodents, UV or a pinched cable)
- Water in a DC connector, isolator or junction box
- A damaged solar panel or backsheet
- Heavy dew or rain can trigger it temporarily on marginal systems
What you can safely do:
- Do not touch panels, DC cables, rooftop isolators or the inverter's DC connectors
- If it clears by itself after the weather dries out, still report it, because repeated alarms point to a developing fault
- Book an electrician or call us. An insulation test needs specialist equipment
- If you see smoke, burn marks or smell burning, keep clear and call 000
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1003Over-temperatureWarning
What it means: The inverter is running too hot, so it has reduced output or paused to protect itself.
Likely causes:
- High ambient temperature or direct afternoon sun on the inverter
- Blocked air vents or heat sink (dust, cobwebs, stored items)
- A fan problem (on fan-cooled models)
What you can safely do:
- Check the unit isn't in direct sun and its vents and cover aren't blocked
- Wait. Sigenergy says it restarts once temperatures return to normal
- If it repeats, report it through mySigen (Support > troubleshooting) or call us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1004Equipment faultFault
What it means: The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.
Sub-IDs: ID1: Malfunction of the power module; ID2: Control module fault; ID3: Auxiliary power supply module fault; ID4: Built-in PID module fault; ID5: Monitoring module fault; ID6: Heating film fault; ID7: External fan fault
Likely causes:
- A one-off disturbance (for example a grid event)
- Internal component or circuit board fault
- Firmware issue
What you can safely do:
- Note the code and sub-ID from the mySigen app
- Restart once using the mySigen app (Settings > turn device off/on), the owner method in the SigenStor Home User Manual
- If the code returns, submit it via the app's Support > troubleshooting page or call us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1005System grounding faultSafety-critical
What it means: The inverter detected a problem with the earth (protective earth/PE) or with the neutral-to-earth connection. A sound earth is essential for electrical safety.
Likely causes:
- Loose or missing earth connection on the inverter or array
- Neutral and earth problem in the AC wiring or switchboard
- Fault in the building's main earth
What you can safely do:
- Do not touch the inverter, frames or cabling
- Leave the system off if it has shut down. Call a licensed electrician or us to test the earthing
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1006PV string overvoltageFault
What it means: The DC voltage coming from the solar panels is higher than the inverter is rated for. Over-voltage can damage the inverter.
Sub-IDs: ID1: String 1 input overvoltage; ID2: String 2 input overvoltage; ID3: String 3 input overvoltage; ID4: String 4 input overvoltage; ID5: String 5 input overvoltage; ID6: String 6 input overvoltage; ID7: String 7 input overvoltage; ID8: String 8 input overvoltage; ID9: String 9 input overvoltage; ID10: String 10 input overvoltage; ID11: String 11 input overvoltage; ID12: String 12 input overvoltage; ID13: String 13 input overvoltage; ID14: String 14 input overvoltage; ID15: String 15 input overvoltage; ID16: String 16 input overvoltage
Likely causes:
- Too many panels wired in series in a string (system design/installation issue)
- Very cold, bright mornings raise panel voltage
- Incorrect panel or string configuration after a change to the system
What you can safely do:
- Do not touch the DC isolator or cables unless the manufacturer's owner shutdown tells you to
- Call us. The string design needs to be checked by a licensed installer
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1007PV string reversely connectedFault
What it means: A solar string or the battery appears to be connected with positive and negative swapped.
Sub-IDs: ID1: String 1 reversely connected; ID2: String 2 reversely connected; ID3: String 3 reversely connected; ID4: String 4 reversely connected; ID5: String 5 reversely connected; ID6: String 6 reversely connected; ID7: String 7 reversely connected; ID8: String 8 reversely connected; ID9: String 9 reversely connected; ID10: String 10 reversely connected; ID11: String 11 reversely connected; ID12: String 12 reversely connected; ID13: String 13 reversely connected; ID14: String 14 reversely connected; ID15: String 15 reversely connected; ID16: String 16 reversely connected
Likely causes:
- Polarity error during installation or maintenance
What you can safely do:
- Do not touch any DC wiring
- Call us or a licensed electrician
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1008PV string sinking currentWarning
What it means: One solar string is behaving differently from the others (lower output or current flowing the wrong way), which often points to a panel, connector or configuration issue.
Sub-IDs: ID1: String 1 sinking current; ID2: String 2 sinking current; ID3: String 3 sinking current; ID4: String 4 sinking current; ID5: String 5 sinking current; ID6: String 6 sinking current; ID7: String 7 sinking current; ID8: String 8 sinking current; ID9: String 9 sinking current; ID10: String 10 sinking current; ID11: String 11 sinking current; ID12: String 12 sinking current; ID13: String 13 sinking current; ID14: String 14 sinking current; ID15: String 15 sinking current; ID16: String 16 sinking current
Likely causes:
- Shading or heavy dirt on part of the array
- Different panel counts or orientations on strings sharing an input
- Faulty panel, connector or cable
What you can safely do:
- From the ground, check for new shading (trees, new structures) or obvious debris
- Compare string readings in your monitoring app if available
- Book a service check if it continues
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1009AFCI faultSafety-critical
What it means: The inverter's arc-fault detection has picked up a pattern that looks like electrical arcing on the DC (solar) side, which can be a fire risk. The inverter shuts down DC power flow as a precaution.
Sub-IDs: ID1: AFCI fault of string 1; ID2: AFCI fault of string 2; ID3: AFCI fault of string 3; ID4: AFCI fault of string 4; ID5: AFCI fault of string 5; ID6: AFCI fault of string 6; ID7: AFCI fault of string 7; ID8: AFCI fault of string 8; ID9: AFCI fault of string 9; ID10: AFCI fault of string 10; ID11: AFCI fault of string 11; ID12: AFCI fault of string 12; ID13: AFCI fault of string 13; ID14: AFCI fault of string 14; ID15: AFCI fault of string 15; ID16: AFCI fault of string 16
Likely causes:
- Loose or poorly crimped DC connector
- Damaged DC cable
- Water or corrosion in a DC connector or isolator
What you can safely do:
- Do not reset it repeatedly and do not touch DC cables or isolators
- If you see smoke or flames or smell burning, keep clear and call 000
- Call us or a licensed electrician to inspect the DC wiring before the system is restarted
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1010Grid power outageWarning
What it means: The inverter cannot see a normal mains supply, so it has stopped exporting to the grid (and a hybrid system may switch to backup).
Likely causes:
- Power outage in your street or area
- A tripped or switched-off solar/inverter circuit breaker in the switchboard
- Loose AC connection between the switchboard and the inverter
What you can safely do:
- Check for a power outage in your area or a tripped breaker in the switchboard
- Sigenergy says the inverter reconnects automatically once the grid is back
- If the grid is fine and it persists, call us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1011Grid overvoltageWarning
What it means: The mains voltage the inverter measured was outside the limits allowed for your network, so it disconnected or reduced output to protect the grid. This is usually a grid condition, not a faulty inverter.
Sub-IDs: ID1: Grid overvoltage Level I; ID2: Grid overvoltage Level II; ID3: Grid overvoltage Level III
Likely causes:
- High street voltage, common on sunny afternoons when many homes export solar
- Grid disturbances or voltage dips
- Long or undersized AC cabling between the inverter and the switchboard (installation issue)
- Grid protection settings that don't match your network's requirements
What you can safely do:
- Wait. The inverter reconnects by itself once voltage is back within limits
- Note the time of day it happens. If it happens most sunny days, tell us, because it may need a voltage check or a report to your network operator
- Don't try to change grid protection settings yourself. In Australia they are set to AS/NZS 4777.2 and your network operator's requirements
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1012Grid undervoltageWarning
What it means: The mains voltage the inverter measured was outside the limits allowed for your network, so it disconnected or reduced output to protect the grid. This is usually a grid condition, not a faulty inverter.
Sub-IDs: ID1: Grid undervoltage Level I; ID2: Grid undervoltage Level II; ID3: Grid undervoltage Level III
Likely causes:
- High street voltage, common on sunny afternoons when many homes export solar
- Grid disturbances or voltage dips
- Long or undersized AC cabling between the inverter and the switchboard (installation issue)
- Grid protection settings that don't match your network's requirements
What you can safely do:
- Wait. The inverter reconnects by itself once voltage is back within limits
- Note the time of day it happens. If it happens most sunny days, tell us, because it may need a voltage check or a report to your network operator
- Don't try to change grid protection settings yourself. In Australia they are set to AS/NZS 4777.2 and your network operator's requirements
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1013Grid overfrequencyWarning
What it means: Grid frequency moved outside the allowed range, so the inverter disconnected or reduced output as the standards require.
Sub-IDs: ID1: Grid overfrequency Level I; ID2: Grid overfrequency Level II; ID3: Grid overfrequency Level III
Likely causes:
- Short grid disturbance
- Running on a generator or a weak supply
- Grid settings that don't match the local network
What you can safely do:
- Wait for automatic reconnection
- If it happens often, record the times and contact us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1014Grid underfrequencyWarning
What it means: Grid frequency moved outside the allowed range, so the inverter disconnected or reduced output as the standards require.
Sub-IDs: ID1: Grid underfrequency Level I; ID2: Grid underfrequency Level II; ID3: Grid underfrequency Level III
Likely causes:
- Short grid disturbance
- Running on a generator or a weak supply
- Grid settings that don't match the local network
What you can safely do:
- Wait for automatic reconnection
- If it happens often, record the times and contact us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1015Grid voltage imbalanceWarning
What it means: The inverter saw something abnormal about the grid supply (for example phase loss, imbalance, waveform distortion or loss of mains), so it disconnected as a safety measure.
Likely causes:
- Grid disturbance or partial outage (for example one phase lost on a 3-phase supply)
- Supply problems on the network side
- Wiring or phase-order errors at installation (if it shows up from day one)
What you can safely do:
- Check whether you have a partial power outage (some circuits or phases off)
- Wait for automatic reconnection after the grid returns to normal
- If it persists or started after electrical work, call us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1016DC component of output current out of limitFault
What it means: The inverter detected too much DC current in its AC output, which the grid standards don't allow, so it disconnected.
Likely causes:
- A one-off disturbance (if it is occasional)
- Internal measuring or power stage problem (if it repeats)
What you can safely do:
- If it happened once and the system recovered, keep an eye on it
- If it repeats, call us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1017Leak current out of limitSafety-critical
What it means: The inverter measured leakage (residual) current flowing to earth above its safety limit and disconnected. This can indicate damaged insulation somewhere in the system.
Likely causes:
- Damaged DC or AC cable insulation
- Moisture in connectors or equipment
- A one-off disturbance (if it happens once and never again)
What you can safely do:
- Don't touch cabling or equipment
- If it happens repeatedly, or together with an insulation/isolation alarm, call an electrician or us promptly
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1018Communication faultWarning
What it means: A communication link has dropped. The sub-ID tells you which one: ID1 4G, ID2 internal CAN, ID3 energy meter, ID4 Gateway. A 4G (ID1) alarm is usually just data or signal, while ID2–ID4 point to wiring or connector problems.
Sub-IDs: ID1: 4G communication fault; ID2: CAN communication fault; ID3: Meter communication fault; ID4: Gateway communication fault
Likely causes:
- Insufficient 4G data or no SIM (ID1)
- Loose internal connector or CAN module fault (ID2)
- Meter or Gateway cable/connector problem (ID3/ID4)
What you can safely do:
- Note the sub-ID shown in the mySigen app
- For ID1, check your Sigen 4G data status in the app
- For other IDs, restart from the mySigen app (Settings) once, then use the app's Support > troubleshooting page or call us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1019Internal protectionFault
What it means: The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.
Sub-IDs: ID1: MPPT1 overcurrent protection; ID2: MPPT2 overcurrent protection; ID3: MPPT3 overcurrent protection; ID4: MPPT4 overcurrent protection; ID5: MPPT5 overcurrent protection; ID6: MPPT6 overcurrent protection; ID7: MPPT7 overcurrent protection; ID8: MPPT8 overcurrent protection; ID9: MPPT9 overcurrent protection; ID10: MPPT10 overcurrent protection; ID11: MPPT11 overcurrent protection; ID12: MPPT12 overcurrent protection; ID13: MPPT13 overcurrent protection; ID14: MPPT14 overcurrent protection; ID15: MPPT15 overcurrent protection; ID16: MPPT16 overcurrent protection; ID17: Inverter output overcurrent protection; ID18: BUS overvoltage protection; ID19: Internal BUS voltage imbalance protection; ID20: Internal control protection
Likely causes:
- A one-off disturbance (for example a grid event)
- Internal component or circuit board fault
- Firmware issue
What you can safely do:
- Note the code and sub-ID from the mySigen app
- Restart once using the mySigen app (Settings > turn device off/on), the owner method in the SigenStor Home User Manual
- If the code returns, submit it via the app's Support > troubleshooting page or call us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1020Abnormal AFCI self-checking circuitFault
What it means: The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.
Sub-IDs: ID1: AFCI self-checking circuit 1 fault; ID2: AFCI self-checking circuit 2 fault; ID3: AFCI self-checking circuit 3 fault; ID4: AFCI self-checking circuit 4 fault; ID5: AFCI self-checking circuit 5 fault; ID6: AFCI self-checking circuit 6 fault; ID7: AFCI self-checking circuit 7 fault; ID8: AFCI self-checking circuit 8 fault; ID9: AFCI self-checking circuit 9 fault; ID10: AFCI self-checking circuit 10 fault; ID11: AFCI self-checking circuit 11 fault; ID12: AFCI self-checking circuit 12 fault; ID13: AFCI self-checking circuit 13 fault; ID14: AFCI self-checking circuit 14 fault; ID15: AFCI self-checking circuit 15 fault; ID16: AFCI self-checking circuit 16 fault
Likely causes:
- A one-off disturbance (for example a grid event)
- Internal component or circuit board fault
- Firmware issue
What you can safely do:
- Note the code and sub-ID from the mySigen app
- Restart once using the mySigen app (Settings > turn device off/on), the owner method in the SigenStor Home User Manual
- If the code returns, submit it via the app's Support > troubleshooting page or call us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1021Inverter AC side voltage abnormalWarning
What it means: The backup/EPS (off-grid) output is overloaded or abnormal, so the system has limited or switched off backup power.
Sub-IDs: ID1: AC side overload protection; ID2: AC side short circuit protection; ID3: AC side overvoltage protection; ID4: AC side undervoltage protection; ID5: AC side overfrequency protection; ID6: AC side underfrequency protection
Likely causes:
- Too many or too large appliances on backup circuits during an outage (for example ovens, air conditioners, pumps)
- High start-up surge from motors or compressors
- A short circuit on a backup circuit
What you can safely do:
- Switch off large appliances on backup circuits
- Wait for the system to retry (some models lock out for a period after repeated overloads)
- If it trips with only small loads on, or you suspect a short circuit, call an electrician
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1022Manual operation protectionInfo
What it means: An emergency power-off (EPO) or emergency shutdown signal has been triggered, so the system has stopped on purpose.
Likely causes:
- Emergency stop or external shutdown switch operated
- Network/demand response command
- Wiring fault on the control input (if nobody operated a switch)
What you can safely do:
- Check whether someone pressed the EPO button or triggered an emergency shutdown
- Only release it, as the manual describes, once the reason for the shutdown is resolved and it is safe
- If nobody triggered it, call us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1024Abnormal phase sequenceWarning
What it means: The inverter saw something abnormal about the grid supply (for example phase loss, imbalance, waveform distortion or loss of mains), so it disconnected as a safety measure.
Likely causes:
- Grid disturbance or partial outage (for example one phase lost on a 3-phase supply)
- Supply problems on the network side
- Wiring or phase-order errors at installation (if it shows up from day one)
What you can safely do:
- Check whether you have a partial power outage (some circuits or phases off)
- Wait for automatic reconnection after the grid returns to normal
- If it persists or started after electrical work, call us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1025Short circuit to PESafety-critical
What it means: The inverter detected a problem with the earth (protective earth/PE) or with the neutral-to-earth connection. A sound earth is essential for electrical safety.
Likely causes:
- Loose or missing earth connection on the inverter or array
- Neutral and earth problem in the AC wiring or switchboard
- Fault in the building's main earth
What you can safely do:
- Do not touch the inverter, frames or cabling
- Leave the system off if it has shut down. Call a licensed electrician or us to test the earthing
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1026Soft start failureFault
What it means: The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.
Likely causes:
- A one-off disturbance (for example a grid event)
- Internal component or circuit board fault
- Firmware issue
What you can safely do:
- Note the code and sub-ID from the mySigen app
- Restart once using the mySigen app (Settings > turn device off/on), the owner method in the SigenStor Home User Manual
- If the code returns, submit it via the app's Support > troubleshooting page or call us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
1027Grid frequency unstableWarning
What it means: Grid frequency moved outside the allowed range, so the inverter disconnected or reduced output as the standards require.
Likely causes:
- Short grid disturbance
- Running on a generator or a weak supply
- Grid settings that don't match the local network
What you can safely do:
- Wait for automatic reconnection
- If it happens often, record the times and contact us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
SigenStor battery & energy-storage (DC) module (8 codes)
2001The software version does not matchFault
What it means: There is a firmware, model or configuration mismatch between parts of the system, so it can't run normally.
Sub-IDs: ID1: Software version mismatch; ID2: Software and hardware version mis- match; ID3: The protocol version does not match
Likely causes:
- Interrupted or partial firmware update
- Parts replaced with different firmware versions
- Incorrect model or country/region setting
What you can safely do:
- Don't try to reflash firmware yourself unless the manufacturer's app tells you to and it's an owner function
- Call us. We can arrange a firmware update or reconfiguration with the manufacturer
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
2002The energy storage module has low insulation resistance to the groundSafety-critical
What it means: The inverter measured low insulation resistance between the solar/battery DC circuits and earth. In Australia this is treated as an earth fault alarm, and the system must be checked by a licensed electrician.
Likely causes:
- Damaged DC cable insulation (for example from rodents, UV or a pinched cable)
- Water in a DC connector, isolator or junction box
- A damaged solar panel or backsheet
- Heavy dew or rain can trigger it temporarily on marginal systems
What you can safely do:
- Do not touch panels, DC cables, rooftop isolators or the inverter's DC connectors
- If it clears by itself after the weather dries out, still report it, because repeated alarms point to a developing fault
- Book an electrician or call us. An insulation test needs specialist equipment
- If you see smoke, burn marks or smell burning, keep clear and call 000
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
2003Over-temperatureSafety-critical
What it means: The battery module or its power module inside the SigenStor is too hot (sub-ID1 power module, ID2 battery module), so operation is limited or stopped.
Sub-IDs: ID1: High temperature of energy storage power module; ID2: High temperature of energy storage battery module
Likely causes:
- High ambient temperature or direct sun on the battery
- Poor ventilation around the battery
- Heavy charge/discharge loads
- An internal battery fault
What you can safely do:
- Keep clear and do not open or touch the battery
- If you notice smoke, a burning or chemical smell, hissing, swelling or leaking, leave the area, keep others away and call 000
- Otherwise, make sure the space around the battery is clear and shaded, and call us or a licensed electrician to check it
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
2004Equipment faultFault
What it means: The battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation.
Sub-IDs: ID1: Energy storage control circuit abnor- mal; ID2: Abnormal energy storage battery module; ID3: Auxiliary power source anomaly; ID4: Master-slave communication anom- aly; ID5: Switch button stuck
Likely causes:
- Cell voltage or capacity imbalance
- Over-charge or over-discharge conditions
- Internal battery hardware (relay, sensor, circuit board) fault
- Firmware or configuration mismatch between battery modules
What you can safely do:
- Do not open the battery or touch its terminals
- Note the exact alarm text and time from the app
- Call us. Battery faults should be handled by the installer or manufacturer
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
2005Under-temperatureWarning
What it means: The battery is too cold to charge or discharge safely, so it is pausing until it warms up.
Likely causes:
- Cold overnight or winter temperatures where the battery is installed
What you can safely do:
- Wait for the battery to warm up. Most systems recover automatically
- If it happens often, ask us whether the location or a heating feature (where the model has one) should be reviewed
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
2006Battery module over-voltageFault
What it means: The battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation.
Likely causes:
- Cell voltage or capacity imbalance
- Over-charge or over-discharge conditions
- Internal battery hardware (relay, sensor, circuit board) fault
- Firmware or configuration mismatch between battery modules
What you can safely do:
- Do not open the battery or touch its terminals
- Note the exact alarm text and time from the app
- Call us. Battery faults should be handled by the installer or manufacturer
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
2007Battery module undervoltageFault
What it means: The battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation.
Likely causes:
- Cell voltage or capacity imbalance
- Over-charge or over-discharge conditions
- Internal battery hardware (relay, sensor, circuit board) fault
- Firmware or configuration mismatch between battery modules
What you can safely do:
- Do not open the battery or touch its terminals
- Note the exact alarm text and time from the app
- Call us. Battery faults should be handled by the installer or manufacturer
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
2008Internal protectionFault
What it means: The battery management system has reported a problem with battery voltage, current, cells or internal hardware and has limited or stopped battery operation.
Sub-IDs: ID1: Overvoltage protection of the power module; ID2: Overvoltage protection of the power module output; ID3: Overcurrent protection of the power module; ID4: Internal series module voltage imbal- ance; ID5: Internal parallel module current im- balance
Likely causes:
- Cell voltage or capacity imbalance
- Over-charge or over-discharge conditions
- Internal battery hardware (relay, sensor, circuit board) fault
- Firmware or configuration mismatch between battery modules
What you can safely do:
- Do not open the battery or touch its terminals
- Note the exact alarm text and time from the app
- Call us. Battery faults should be handled by the installer or manufacturer
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
Sigen Gateway (backup/grid switching) (15 codes)
3001The software version does not matchFault
What it means: There is a firmware, model or configuration mismatch between parts of the system, so it can't run normally.
Sub-IDs: ID1: Software and hardware version mis- match; ID2: Protocol version mismatch between devices
Likely causes:
- Interrupted or partial firmware update
- Parts replaced with different firmware versions
- Incorrect model or country/region setting
What you can safely do:
- Don't try to reflash firmware yourself unless the manufacturer's app tells you to and it's an owner function
- Call us. We can arrange a firmware update or reconfiguration with the manufacturer
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
3002Over-temperatureWarning
What it means: The inverter is running too hot, so it has reduced output or paused to protect itself.
Sub-IDs: ID1: Temperature too high; ID2: Temperature On The Grid Side Is Too High; ID3: Temperature On The Oil Engine Side Is Too High; ID4: Backup Port Temperature Too High; ID5: Load Port Temperature Too High
Likely causes:
- High ambient temperature or direct afternoon sun on the inverter
- Blocked air vents or heat sink (dust, cobwebs, stored items)
- A fan problem (on fan-cooled models)
What you can safely do:
- Check the unit isn't in direct sun and its vents and cover aren't blocked
- Wait. Sigenergy says it restarts once temperatures return to normal
- If it repeats, report it through mySigen (Support > troubleshooting) or call us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
3003Equipment faultFault
What it means: The equipment's self-checks found an internal problem (for example relays, measuring circuits, internal communication or power electronics). Some of these clear by themselves after a one-off event, but repeated alarms usually need a technician.
Sub-IDs: ID1: Auxiliary power source abnormal; ID2: Internal communication failure; ID3: Control circuit fault; ID4: Grid contactor open circuit fault; ID5: Grid contactor short circuit fault; ID6: Engine contactor open circuit fault; ID7: Engine contactor short circuit fault; ID8: Neutral point grounding relay open circuit fault; ID9: Neutral point grounding relay short circuit fault; ID8: Neutral point grounding relay open circuit fault; ID9: Neutral point grounding relay short circuit fault
Likely causes:
- A one-off disturbance (for example a grid event)
- Internal component or circuit board fault
- Firmware issue
What you can safely do:
- Note the code and sub-ID from the mySigen app
- Restart once using the mySigen app (Settings > turn device off/on), the owner method in the SigenStor Home User Manual
- If the code returns, submit it via the app's Support > troubleshooting page or call us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
3004Too high off-grid output leak currentSafety-critical
What it means: The inverter measured leakage (residual) current flowing to earth above its safety limit and disconnected. This can indicate damaged insulation somewhere in the system.
Likely causes:
- Damaged DC or AC cable insulation
- Moisture in connectors or equipment
- A one-off disturbance (if it happens once and never again)
What you can safely do:
- Don't touch cabling or equipment
- If it happens repeatedly, or together with an insulation/isolation alarm, call an electrician or us promptly
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
3005Neutral point grounding faultSafety-critical
What it means: The inverter detected a problem with the earth (protective earth/PE) or with the neutral-to-earth connection. A sound earth is essential for electrical safety.
Likely causes:
- Loose or missing earth connection on the inverter or array
- Neutral and earth problem in the AC wiring or switchboard
- Fault in the building's main earth
What you can safely do:
- Do not touch the inverter, frames or cabling
- Leave the system off if it has shut down. Call a licensed electrician or us to test the earthing
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
3006Abnormal Phase Se- quence Of Power Grid WiringFault
What it means: The inverter has detected an AC wiring problem, for example active and neutral swapped or a connection made the wrong way round.
Likely causes:
- AC wiring error at installation or after other electrical work
- Wiring on the meter or CT the wrong way round
What you can safely do:
- Do not touch any wiring
- Leave the system as it is and book a licensed electrician (or call us)
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
3007Load Side Wiring Phase Sequence AbnormalFault
What it means: The inverter has detected an AC wiring problem, for example active and neutral swapped or a connection made the wrong way round.
Likely causes:
- AC wiring error at installation or after other electrical work
- Wiring on the meter or CT the wrong way round
What you can safely do:
- Do not touch any wiring
- Leave the system as it is and book a licensed electrician (or call us)
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
3008Grid phase lossWarning
What it means: The inverter saw something abnormal about the grid supply (for example phase loss, imbalance, waveform distortion or loss of mains), so it disconnected as a safety measure.
Likely causes:
- Grid disturbance or partial outage (for example one phase lost on a 3-phase supply)
- Supply problems on the network side
- Wiring or phase-order errors at installation (if it shows up from day one)
What you can safely do:
- Check whether you have a partial power outage (some circuits or phases off)
- Wait for automatic reconnection after the grid returns to normal
- If it persists or started after electrical work, call us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
3009Grid failureWarning
What it means: The mains voltage the inverter measured was outside the limits allowed for your network, so it disconnected or reduced output to protect the grid. This is usually a grid condition, not a faulty inverter.
Sub-IDs: ID1: Grid phase A overvoltaged; ID2: Grid phase B overvoltaged; ID3: Grid phase C overvoltaged; ID4: Grid phase A undervoltaged; ID5: Grid phase B undervoltaged; ID6: Grid phase C undervoltaged; ID7: Grid overfrequency; ID8: Grid underfrequency
Likely causes:
- High street voltage, common on sunny afternoons when many homes export solar
- Grid disturbances or voltage dips
- Long or undersized AC cabling between the inverter and the switchboard (installation issue)
- Grid protection settings that don't match your network's requirements
What you can safely do:
- Wait. The inverter reconnects by itself once voltage is back within limits
- Note the time of day it happens. If it happens most sunny days, tell us, because it may need a voltage check or a report to your network operator
- Don't try to change grid protection settings yourself. In Australia they are set to AS/NZS 4777.2 and your network operator's requirements
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
3010Generator failureWarning
What it means: A problem was detected with a connected generator input (voltage, frequency, wiring or start-up).
Sub-IDs: ID1: Generator phase A overvoltaged; ID2: Generator phase B overvoltaged; ID3: Generator phase C overvoltaged; ID4: Generator phase A undervoltaged; ID5: Generator phase B undervoltaged; ID6: Generator phase C undervoltaged; ID7: Generator overfrequency; ID8: Generator underfrequency
Likely causes:
- Generator output out of range
- Generator wiring or phase-order error
- Generator failed to start
What you can safely do:
- Check the generator itself (fuel, its own alarms)
- Call us to check the generator integration
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
3011Load faultWarning
What it means: The backup/EPS (off-grid) output is overloaded or abnormal, so the system has limited or switched off backup power.
Sub-IDs: ID1: Overvoltage on Load Phase A; ID2: Overvoltage on Load Phase B; ID3: Overvoltage on Load Phase C; ID4: Undervoltage on Load Phase A; ID5: Undervoltage on Load Phase B; ID6: Undervoltage on Load Phase C; ID7: Overfrequency on Load; ID8: Underfrequency on Load
Likely causes:
- Too many or too large appliances on backup circuits during an outage (for example ovens, air conditioners, pumps)
- High start-up surge from motors or compressors
- A short circuit on a backup circuit
What you can safely do:
- Switch off large appliances on backup circuits
- Wait for the system to retry (some models lock out for a period after repeated overloads)
- If it trips with only small loads on, or you suspect a short circuit, call an electrician
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
3012Abnormal phase sequence of engine connectionWarning
What it means: A problem was detected with a connected generator input (voltage, frequency, wiring or start-up).
Likely causes:
- Generator output out of range
- Generator wiring or phase-order error
- Generator failed to start
What you can safely do:
- Check the generator itself (fuel, its own alarms)
- Call us to check the generator integration
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
3013Emergency shutdownInfo
What it means: An emergency power-off (EPO) or emergency shutdown signal has been triggered, so the system has stopped on purpose.
Likely causes:
- Emergency stop or external shutdown switch operated
- Network/demand response command
- Wiring fault on the control input (if nobody operated a switch)
What you can safely do:
- Check whether someone pressed the EPO button or triggered an emergency shutdown
- Only release it, as the manual describes, once the reason for the shutdown is resolved and it is safe
- If nobody triggered it, call us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
3014Bypass Switch OpenWarning
What it means: The Gateway's bypass switch is reported open/abnormal.
Likely causes:
- Bypass switch operated (for maintenance)
- Gateway fault
What you can safely do:
- Note the code and sub-ID from the mySigen app
- Restart once using the mySigen app (Settings > turn device off/on), the owner method in the SigenStor Home User Manual
- If the code returns, submit it via the app's Support > troubleshooting page or call us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
3015Bypass Switch OnWarning
What it means: The Gateway's bypass switch is reported switched on (system bypassed).
Likely causes:
- Bypass switch operated (for maintenance)
- Gateway fault
What you can safely do:
- If nobody has operated the bypass switch, call us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
System / communication (3 codes)
4001Communication faultWarning
What it means: The inverter isn't getting correct readings from its energy meter or current sensor (CT). This affects export limiting, battery charging and monitoring accuracy.
Sub-IDs: ID1: Gateway communication anomaly; ID2: Electric meter communication anom- aly; ID3: AC power sensor communication anomaly
Likely causes:
- Meter or CT communication cable loose or damaged
- CT clamp fitted on the wrong cable or the wrong way round
- Meter has lost power or is faulty
What you can safely do:
- Check the app. Generation may still be running normally
- Don't open the switchboard
- Call us to check the meter/CT wiring. If your system has an export limit, this needs fixing promptly
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
4003Diesel generator startup failureWarning
What it means: A problem was detected with a connected generator input (voltage, frequency, wiring or start-up).
Likely causes:
- Generator output out of range
- Generator wiring or phase-order error
- Generator failed to start
What you can safely do:
- Check the generator itself (fuel, its own alarms)
- Call us to check the generator integration
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
4004CLS faultWarning
What it means: Sigenergy lists a "CLS malfunction" and says it can be cleared manually in the app. The manual doesn't explain the term further.
Likely causes:
- Not specified by the manufacturer
What you can safely do:
- Clear it from the mySigen app as Sigenergy describes
- If it returns, call us
Source: Sigenergy Alarm List, Version 04, released 2024-11-18
Manufacturer support contacts
| Contact | Phone | Email / channel |
|---|---|---|
| Sigenergy Australia (sales & service) (website) | 0489 080 832 | service.au@sigenergy.com |
If Total Solar installed your system, contact us first.
Need help with a fault code?
Book a service call with our licensed electricians, or call us to talk it through. Have your fault code and a photo of the screen or app ready.