Sigenergy SigenStor / Sigen Hybrid / Gateway / battery error codes explained

What 95 Sigenergy SigenStor / Sigen Hybrid / Gateway / battery inverter & battery fault and error codes mean, in plain English, with safe checks you can do and when to call a licensed electrician.

Guide only. This information is a general guide taken from manufacturer documentation. All electrical work must be performed by a licensed electrician. Never open your inverter, battery or switchboard. If you see smoke, smell burning or see damage, keep clear and call 000.
CodeMessage & meaningModelType
1001Warning
The software version does not match

The inverter software version does not match The equipment's internal software version does not match If the upgrade is unsuccessful, please submit fault feedback on the APP-service-troubleshooting page.

What you can do

  • Make sure the system is online so it can receive updates
  • Restart the system once using the owner steps in your manual
  • If the alarm stays, call your installer - settings and firmware must be fixed by them or the manufacturer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1002Safety-Critical
Low insulation resistance

Low insulation resistance The PV string is short circuited to the PE, or the PV string is installed in a chronically humid env 1

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1003Warning
Over-temperature

Inverter over-temperature Too high ambient temperature, poor ventilation in the installation location Malfunction of the int Generally, the machine will be restarted after the internal temperature or module temperature returns to nor- mal, if the failure occurs repeatedly: 1

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1004Fault
Equipment fault

Malfunction of the power module Internal circuit fault 1

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1005Safety-Critical
System grounding fault

System grounding fault PE cable not grounded 1

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1006Fault
PV string overvoltage

String 1 input overvoltage Too many strings in series

What you can do

  • Do not touch the DC isolators or cables
  • Note the time - this often shows on cold, very sunny mornings
  • Call your installer - the panel strings may need to be checked against the inverter's limits

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1007Fault
PV string reversely con- nected

String 1 reversely connected Positive and negative terminals reversely con- nected 1

What you can do

  • Do not touch the DC isolators, cables or connectors
  • Call your installer - this points to a wiring problem that needs a licensed electrician

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1008Fault
PV string sinking current

String 1 sinking current Inconsistent configuration of strings 1

What you can do

  • Check solar generation in the app compared with similar days
  • Do not touch the DC isolators, cables or connectors, and don't go on the roof
  • If it doesn't clear by itself, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1009Safety-Critical
AFCI fault

AFCI fault of string 1 DC cable damaged Poor contact of string con- nector 1

What you can do

  • Keep clear of the inverter, panels and DC cables, and do not touch any isolators
  • Note the code, date and time, and check whether the alarm is still showing in the app
  • If you smell burning or see smoke, get everyone out and call 000
  • Call a licensed electrician or Total Solar - an arc fault means a DC wiring or connector problem that must be inspected

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1010Info
Grid power outage

Grid power outage Grid power outage or AC switch turned off Under normal circumstances, the inverter will be reconnected to the grid after the grid returns to normal

What you can do

  • Check whether the rest of your house or street has power, and check your network operator's outage map
  • Check the switchboard for a tripped solar/inverter breaker - reset it once only; if it trips again, leave it off and call an electrician
  • Once normal power is back the inverter usually reconnects on its own within a few minutes
  • If the power is normal but the alarm stays, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1011Warning
Grid overvoltage

Grid overvoltage Level I The grid voltage is greater than the overvoltage threshold Level I Under normal circumstances, the inverter will be reconnected to the grid after the grid returns to normal

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1012Warning
Grid undervoltage

Grid undervoltage Level I The grid voltage is less than the undervoltage threshold I Under normal circumstances, the inverter will be reconnected to the grid after the grid returns to normal

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1013Warning
Grid overfrequency

Grid overfrequency Level I The grid frequency is greater than the overfre- quency threshold Level I Under normal circumstances, the inverter will be reconnected to the grid after the grid returns to normal

What you can do

  • This is caused by the mains frequency moving outside the allowed range, usually briefly
  • The inverter reconnects by itself once the grid is stable
  • If it keeps happening, note the times and call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1014Warning
Grid underfrequency

Grid underfrequency Level I The grid frequency is less than the underfrequen- cy threshold Level I Under normal circumstances, the inverter will be reconnected to the grid after the grid returns to normal

What you can do

  • This is caused by the mains frequency moving outside the allowed range, usually briefly
  • The inverter reconnects by itself once the grid is stable
  • If it keeps happening, note the times and call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1015Warning
Grid voltage imbalance

Grid voltage imbalance Three-phase grid phase angle imbalance Three- phase grid amplitude imbalance Under normal circumstances, the inverter will be reconnected to the grid after the grid returns to normal

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1016Fault
DC component of output current out of limit

DC component of output current out of limit The DC component in the AC output current is greater than the set point 1

What you can do

  • Restart the system once using the owner shutdown/start-up steps in your manual
  • If it comes back, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1017Safety-Critical
Leak current out of limit

Leak current out of limit The leak current exceeds the protection threshold This may be occasionally caused by transient environmental changes

What you can do

  • Keep clear and do not touch the inverter or cabling
  • Note the code, date and time
  • Call a licensed electrician or Total Solar - this alarm means current may be leaking to earth

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1018Warning
Communication fault

4G communication fault Insufficient 4G traffic or SIM card not inserted Poor contact of internal communication Dongle Please check the 4G data, if the data is insufficient, please recharge

What you can do

  • Check that your home Wi-Fi/internet is working and restart your router
  • Wait an hour - monitoring often reconnects by itself
  • If the inverter screen also shows a fault, or the alarm stays for more than a day, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1019Fault
Internal protection

MPPT1 overcurrent protection MPPT overcurrent protection triggered This may be occasionally caused by transient environmental changes

What you can do

  • Check solar generation in the app compared with similar days
  • Do not touch the DC isolators, cables or connectors, and don't go on the roof
  • If it doesn't clear by itself, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1020Safety-Critical
Abnormal AFCI self-check- ing circuit

AFCI self-checking circuit 1 fault DC arc detection circuit self-checking failed 1

What you can do

  • Keep clear of the inverter, panels and DC cables, and do not touch any isolators
  • Note the code, date and time, and check whether the alarm is still showing in the app
  • If you smell burning or see smoke, get everyone out and call 000
  • Call a licensed electrician or Total Solar - an arc fault means a DC wiring or connector problem that must be inspected

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1021Warning
Inverter AC side voltage abnormal

AC side overload protection AC side voltage below threshold 1

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1022Fault
Manual operation protec- tion

EPO protection The customer presses the rapid shutdown button in emergency

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1023Fault
Neutral line abnormality in inverter

Neutral wire disconnected in the inverter The neutral line in the inverter is not connected or is loose 1

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1024Warning
Abnormal phase sequence

Abnormal phase sequence of three-phase grid Abnormal phase sequence of three-phase grid Adjust the sequence of the three-phase wiring on the AC output side

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1025Safety-Critical
Short circuit to PE

Three-phase grid is short circuited to the PE Three-phase grid is short circuited to the PE Check if there is a phase-to-ground short circuit on the grid side wiring

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1026Fault
Soft start failure

Soft start failure Soft start failure If it occurs accidentally, it may be caused by a transient change in the environment

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1028Fault
Built-in GATEWAY device failure

Grid port relay open circuit fault Internal circuit failure in the equipment 1

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1029Fault
Built-in GATEWAY wiring abnormal

Abnormal grid connection phase sequence Abnormal grid connection 1

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1030Warning
Built-in GATEWAY load failure

Phase A load overvoltage Low phase A voltage of the load 1

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
1031Fault
Built-in GATEWAY port overcurrent

Overcurrent at grid-side phase A port Excessive current flows through the A-phase port on the grid side 1

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2001Warning
The software version does not match

Software version mismatch The equipment's internal software version does not match Please upgrade the system software again; If the fault still exists, please submit fault feedback on the APP-service-support-troubleshooting page.

What you can do

  • Make sure the system is online so it can receive updates
  • Restart the system once using the owner steps in your manual
  • If the alarm stays, call your installer - settings and firmware must be fixed by them or the manufacturer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2002Safety-Critical
The energy storage module has low insulation resist- ance to the ground

Energy storage module has low insulation impedance to ground The energy storage module is short circuited to the housing 1

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2003Warning
Over-temperature

High temperature of energy storage power module Too high ambient temperature, poor ventilation in the installation location Malfunction of the in- ternal power module results in abnormal internal heating

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2004Fault
Equipment fault

Energy storage control circuit abnormal Internal circuit fault 1

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2005Safety-Critical
Under-temperature

Low temperature of energy storage battery module Too low ambient temperature 1

What you can do

  • Check from a safe distance for heat, swelling, hissing, a burning smell or smoke - if you notice any, keep everyone away and call 000
  • If nothing looks wrong, make sure the battery area is shaded and ventilated and nothing is stacked against it
  • Let the battery cool; most units recover by themselves
  • If the alarm keeps returning, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2006Fault
Battery module over-volt- age

Battery module overvoltage Too high voltage of the battery module or cells therein

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2007Fault
Battery module undervolt- age

Battery module undervoltage Too low voltage of the battery module or cells therein

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2008Fault
Internal protection

Overvoltage protection of the pow- er module Internal overvoltage protection triggered 1

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2101Warning
Software Version Mismatch

Software Version Mismatch The internal software version of the all-in-one machine does not match Please upgrade again

What you can do

  • Make sure the system is online so it can receive updates
  • Restart the system once using the owner steps in your manual
  • If the alarm stays, call your installer - settings and firmware must be fixed by them or the manufacturer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2102Safety-Critical
Low Insulation Resistance To Ground In Energy Stor- age Cluster

Low Insulation Resistance To Ground Of Energy Storage Module Internal Short Circuit To The Enclosure Of The Energy Storage Module 1

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2103Warning
Temperature Of The Power Module In The Energy Stor- age Cluster Is Too High

High Temperature In Energy Stor- age Power Module The ambient temperature is too high, the equip- ment installation location is not ventilated; the power module inside the equipment is malfunc- tioning 1

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2104Safety-Critical
Battery Module Temper- ature In Energy Storage Cluster Too High

Energy Storage Battery Module Temperature High

What you can do

  • Check from a safe distance for heat, swelling, hissing, a burning smell or smoke - if you notice any, keep everyone away and call 000
  • If nothing looks wrong, make sure the battery area is shaded and ventilated and nothing is stacked against it
  • Let the battery cool; most units recover by themselves
  • If the alarm keeps returning, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2105Fault
Equipment Failure

Energy Storage Control Circuit Abnormal Internal Circuit Malfunction 1

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2106Safety-Critical
Temperature Too Low

Energy Storage Battery Module Temperature Low Ambient Temperature Is Too Low 1.Wait for the ambient temperature to rise to the operating temperature range of the equipment, and the fault can be automatically resolved

What you can do

  • Check from a safe distance for heat, swelling, hissing, a burning smell or smoke - if you notice any, keep everyone away and call 000
  • If nothing looks wrong, make sure the battery area is shaded and ventilated and nothing is stacked against it
  • Let the battery cool; most units recover by themselves
  • If the alarm keeps returning, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2107Fault
Battery Cluster Module Overvoltage

Battery Module Overvoltage Battery module or cell voltage within the module is too high; battery module overcharged Please Submit Fault Feedback On The APP-support-troubleshooting Page

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2108Fault
Battery Cluster Module Undervoltage

Battery Module Undervoltage Battery module or cell voltage within the module is too low, long-term storage leads to power loss Please Submit Fault Feedback On The APP-support-troubleshooting Page

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2109Fault
Internal equipment protec- tion

Power module input overvoltage protection Trigger the internal overvoltage protection mech- anism of the device 1

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2110Fault
Cluster power limitation

Battery cluster module overcurrent power limit The charge and discharge current of the battery module is relatively large 1

What you can do

  • Turn off any very large loads that were running when the alarm appeared
  • Wait - many over-current protections reset automatically
  • If it keeps happening, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2111Fault
Wiring abnormality

Abnormal DC busbar wiring DC busbar positive and negative poles reversed 1

What you can do

  • Do not touch the DC isolators, cables or connectors
  • Call your installer - this points to a wiring problem that needs a licensed electrician

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2201Warning
Version mismatch

Software version mismatch The internal software version of the all-in-one machine does not match Please upgrade again, if the fault still exists, please submit a fault report on the APP-support-troubleshoot- ing page

What you can do

  • Make sure the system is online so it can receive updates
  • Restart the system once using the owner steps in your manual
  • If the alarm stays, call your installer - settings and firmware must be fixed by them or the manufacturer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2202Safety-Critical
Battery module tempera- ture too high

High temperature of energy storage battery module The ambient temperature is too high, and the installation location is not ventilated 1

What you can do

  • Check from a safe distance for heat, swelling, hissing, a burning smell or smoke - if you notice any, keep everyone away and call 000
  • If nothing looks wrong, make sure the battery area is shaded and ventilated and nothing is stacked against it
  • Let the battery cool; most units recover by themselves
  • If the alarm keeps returning, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2203Warning
Equipment failure

Auxiliary source anomaly Auxiliary module anomaly: balancing module abnormal; detection module anomaly: generally refers to overcurrent, voltage difference 1

What you can do

  • Check that your home Wi-Fi/internet is working and restart your router
  • Wait an hour - monitoring often reconnects by itself
  • If the inverter screen also shows a fault, or the alarm stays for more than a day, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2204Safety-Critical
Temperature too low

The temperature of the energy storage battery module is low Ambient temperature too low 1

What you can do

  • Check from a safe distance for heat, swelling, hissing, a burning smell or smoke - if you notice any, keep everyone away and call 000
  • If nothing looks wrong, make sure the battery area is shaded and ventilated and nothing is stacked against it
  • Let the battery cool; most units recover by themselves
  • If the alarm keeps returning, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2205Fault
Battery module overvoltage

Battery module overvoltage The battery module or the cell voltage within the module is too high Please submit fault feedback on the APP-support-troubleshooting page

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2206Fault
Battery module undervolt- age

Battery module undervoltage The battery module or the cell voltage within the module is too low Please submit fault feedback on the APP-support-troubleshooting page

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2207Fault
The power of the battery module is limited

Battery module voltage high limit power The voltage of the battery module or the cells within the module is relatively high 1

What you can do

  • Note the code and the battery state of charge shown in the app
  • Let the system run - some battery voltage protections clear by themselves after charging or discharging
  • If the alarm stays or keeps returning, call your installer - don't open or disconnect the battery yourself

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2301Warning
Software version mismatch

Protocol version mismatch The internal software versions of the device do not match Version mismatch or upgrade unsuccessful, please upgrade again

What you can do

  • Make sure the system is online so it can receive updates
  • Restart the system once using the owner steps in your manual
  • If the alarm stays, call your installer - settings and firmware must be fixed by them or the manufacturer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2302Warning
Overtemperature

Junction box temperature is high The ambient temperature is too high, and the installation location of the equipment is not ven- tilated The internal power module of the equipment is malfunctioning, resulting in severe internal heating 1

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2303Fault
Equipment failure

AC soft start failure Internal circuit failure in the equipment 1

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
2304Warning
Wiring abnormality

Power line reverse connection The power cable or network cable is not properly connected 1

What you can do

  • Check that your home Wi-Fi/internet is working and restart your router
  • Wait an hour - monitoring often reconnects by itself
  • If the inverter screen also shows a fault, or the alarm stays for more than a day, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
3001Warning
The software version does not match

Software and hardware version mismatch Mismatched versions of various subcomponents in the all-in-one system

What you can do

  • Make sure the system is online so it can receive updates
  • Restart the system once using the owner steps in your manual
  • If the alarm stays, call your installer - settings and firmware must be fixed by them or the manufacturer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
3002Warning
Over-temperature

Temperature too high High ambient temperature, inadequate ventilation at the equipment installation location; abnormal operation of internal components in the device

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
3003Fault
Equipment fault

Auxiliary power source abnormal Internal circuit failure in the device

What you can do

  • Note the code, then restart the system once using the owner shutdown/start-up steps in your manual
  • If the code comes back, call your installer - this is an internal fault that needs a licensed electrician or the manufacturer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
3004Safety-Critical
Too high off-grid output leak current

Excessive off-grid output leakage current Off-grid scenario, high leakage current in the load

What you can do

  • Keep clear and do not touch the inverter or cabling
  • Note the code, date and time
  • Call a licensed electrician or Total Solar - this alarm means current may be leaking to earth

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
3005Safety-Critical
Neutral point grounding fault

Neutral point grounding fault Off-grid scenario: High voltage between N and PE; LN reversed (European gateway) Check if the functional ground is effectively connected to the external ground

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
3006Fault
Abnormal Phase Sequence Of Power Grid Wiring

Grid wiring phase sequence abnor- mality Power Grid Connection Abnormality 1

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
3007Fault
Load Side Wiring Phase Sequence Abnormal

Inverter wiring phase sequence abnormality Load Side Wiring Abnormality 1

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
3008Warning
Grid phase loss

Grid phase loss For three-phase equipment, if the three-phase grid voltage is not fully connected to the equip- ment, there is a lack of one phase or two phases in the grid voltage

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
3009Info
Grid failure

Grid phase A overvoltaged Grid phase A voltage is too high 1

What you can do

  • Check whether the rest of your house or street has power, and check your network operator's outage map
  • Check the switchboard for a tripped solar/inverter breaker - reset it once only; if it trips again, leave it off and call an electrician
  • Once normal power is back the inverter usually reconnects on its own within a few minutes
  • If the power is normal but the alarm stays, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
3010Warning
Generator failure

Generator phase A overvoltaged Generator phase A voltage is too high 1

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
3011Warning
Load fault

Overvoltage on Load Phase A High Voltage on Load Phase A 1

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
3012Fault
Abnormal phase sequence of engine connection

Abnormal phase sequence of en- gine connection Abnormal Wiring Of Oil Machine 1

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
3014Fault
Bypass Switch Open

Bypass Switch Abnormal Bypass switch open, cannot close 1

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
3015Fault
Bypass Switch On

Bypass Switch On Bypass Switch On 1

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
3016Warning
Contactor coil overvoltage

Grid contactor coil overvoltage Grid contactor coil overvoltage 1

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
3017Fault
The cabinet door opens

The cabinet door opens The cabinet door status feedback contact is high resistance 1

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
3018Fault
Frame circuit breaker over- current protection

Overcurrent protection for grid-side frame circuit breaker The feedback contact of the grid-side frame cir- cuit breaker fault is low resistance

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
3019Fault
Frame circuit breaker ex- ceeds service life

The mechanical lifespan of the grid framework circuit breaker has been exceeded The mechanical lifespan of the grid framework circuit breaker has been exceeded 1

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
4001Warning
Communication fault

Gateway communication anomaly Poor communication contact between the gate- way and the all-in-one machine 1

What you can do

  • Check that your home Wi-Fi/internet is working and restart your router
  • Wait an hour - monitoring often reconnects by itself
  • If the inverter screen also shows a fault, or the alarm stays for more than a day, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
4002Warning
Wiring anomaly

Phase A CT reverse connection Phase A CT reverse connection Rewire according to the cause

What you can do

  • Check the monitoring app for the alarm and whether export/consumption readings look wrong
  • Restart your home router if the meter talks over Wi-Fi or LAN
  • Call your installer - meter and CT wiring is inside the switchboard and must be checked by a licensed electrician

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
4003Fault
Diesel generator startup failure

Engine start anomaly Engine start anomaly None

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
4004Fault
CLS fault

CLS malfunction CLS malfunction Clearing the fault on the App.

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
4005Fault
Feed-in power limit hard protection

Feed-in power limit protection When the grid feed-in power limit hard protection is enabled, exceeding the grid feed-in power limit will trigger hard protection

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
4006Safety-Critical
DI custom fault

OVGR fault Ground fault overvoltage relay triggers protection Please check for any system grounding faults

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
5001Warning
Equipment protection

Grid input overvoltage Actual grid voltage exceeds rated voltage by 20%

What you can do

  • This is usually caused by the mains supply, not the solar system
  • The inverter normally reconnects by itself once grid voltage is back in range
  • If it happens often (especially on sunny afternoons), note the times and call your installer - they can check the voltage and settings and talk to the network if needed

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
5002Safety-Critical
Equipment fault

Leakage detection circuit abnormal Leakage detection circuit failure 1

What you can do

  • Keep clear and do not touch the inverter or cabling
  • Note the code, date and time
  • Call a licensed electrician or Total Solar - this alarm means current may be leaking to earth

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
5003Warning
Over-temperature

Internal temperature too high 1

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
5004Info
Charging cable fault

Charging cable specification ab- normal For a charger with a socket, the charging cable has abnormal current-carrying capacity

What you can do

  • This normally means the battery is low or has reached its reserve level
  • Let the system recharge from solar or the grid - check the state of charge in the app
  • If the battery never charges or stays at 0% for more than a day of sunshine, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
5005Warning
Meter communication fault

Meter communication abnormal The meter loses communication with the charger for more than 1 minute

What you can do

  • Check the monitoring app for the alarm and whether export/consumption readings look wrong
  • Restart your home router if the meter talks over Wi-Fi or LAN
  • Call your installer - meter and CT wiring is inside the switchboard and must be checked by a licensed electrician

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
5101Warning
The software version does not match

Software version mismatch The equipment's internal software version does not match If the version does not match or the upgrade is unsuccessful, please upgrade again, if the upgrade is unsuc- cessful for multiple times, Please submit a fault report on the support-troubleshooting page of the mySigen app.

What you can do

  • Make sure the system is online so it can receive updates
  • Restart the system once using the owner steps in your manual
  • If the alarm stays, call your installer - settings and firmware must be fixed by them or the manufacturer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
5102Safety-Critical
Low insulation resistance

Low insulation resistance The resistance of the positive and negative bus- bars to ground is too small 1

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
5103Warning
Over-temperature

Internal temperature too high The ambient temperature is too high, and the equipment is installed in a poorly ventilated loca- tion; The power module inside the equipment is malfunctioning, leading to severe internal heat- ing; The LLC power module is overheating, and the BUCK power module is also overheating

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
5104Warning
Equipment fault

External fan malfunction External fan malfunction 1

What you can do

  • Check from a safe distance that the inverter is shaded, has clear space around it and that nothing is blocking the vents
  • It usually recovers once it cools down
  • If it repeats often or you can hear a noisy/failed fan, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
5105Safety-Critical
Charging fault

Control guidance malfunction CP pin disconnection, CP to ground short circuit 1

What you can do

  • Do not touch the panels, rooftop isolators or DC cables
  • Note the code and whether it appears in wet weather or early morning - this helps the electrician
  • If it clears by itself once things dry out, still let us know if it keeps returning
  • Call a licensed electrician or Total Solar - insulation and earth faults need testing with proper equipment

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter
5106Fault
Equipment protection

Overvoltage protection LLC overvoltage, BUCK overvoltage 1

What you can do

  • Note the code, date and time and check the monitoring app
  • Restart the system once using the owner shutdown/start-up steps in your manual if it allows
  • If it comes back, call your installer

SigenStor / Sigen Hybrid / Gateway / battery · Guide only. All work must be done by a licensed electrician.

SigenStor / Sigen Hybrid / Gateway / battery Inverter

Need help with this fault?

Get a licensed electrician to call you back.

Total Solar can help: our licensed electricians install and service systems. Based in Ellenbrook, WA, with Victoria and Queensland also available.

Or call 1300 209 503

By sending this form you agree to Total Solar (THK Group Pty Ltd) contacting you by phone, SMS or email about this request. We use your details only to respond, as set out in our Privacy Policy.

Sources

Meanings are summarised from these manufacturer documents. Check your own model's manual, as codes vary between models and firmware versions.

Sigenergy is a trademark of its owner. Total Solar is not affiliated with the manufacturer unless stated. All fault code guides

Get a quote Call